3F4 - Ferroxcube

FERROXCUBE
DATA SHEET
3F4
Material specification
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
Material specification
3F4
3F4 SPECIFICATIONS
A high frequency power material for use in power and
general purpose transformers at frequencies of
1 - 2 MHz.
SYMBOL
CONDITIONS
VALUE
µi
25 °C; ≤10 kHz;
0.25 mT
900 ±20%
µa
100 °C; 25 kHz;
200 mT
≈ 1700
B
25 °C; 10 kHz;
1200 A/m
≈ 410
100 °C; 10 kHz;
1200 A/m
≈ 350
100 °C; 1 MHz;
30 mT
≈ 130
100 °C; 3 MHz;
10 mT
≈ 220
PV
ρ
DC; 25 °C
MBW025
10 4
handbook, halfpage
3F4
µ's , µ''s
UNIT
10 3
µ's
µ''s
mT
10 2
kW/m 3
≈ 10
Ωm
TC
≥ 220
°C
density
≈ 4700
kg/m3
10
10 1
Fig.1
MBW034
2000
handbook, halfpage
10
10 2
f (MHz)
Complex permeability as
a function of frequency.
MBW017
500
25oC
100oC
handbook, halfpage
3F4
µi
1
B
(mT)
3F4
400
1500
300
1000
200
500
100
0
50
0
50
Fig.2
2008 Sep 01
150
T ( o C)
250
50
0
50
100
500
1000
H (A/m)
Initial permeability as a
function of temperature.
Fig.3 Typical B-H loops.
185
Ferroxcube
Material specification
3F4
MBW046
2000
25 C
o
100 C
µa
MBW035
10 4
handbook, halfpage
o
handbook, halfpage
3F4
3F4
µ rev
1500
10 3
1000
10 2
500
10
0
0
100
200
300
400
10 2
10
1
B (mT)
Fig.4
Amplitude permeability as
function of peak flux density.
Fig.5
MBW047
10 4
handbook, halfpage
T = 100 oC
3F4
Pv
(kW/m 3 )
f
B
(kHz) (mT)
300
25 k
Hz
10 3
MBW056
400
1 MH
z
400 k
Hz
200
1 0 0 kHz
kHz
3M
Hz
2M
Hz
(kW/m 3)
Reversible permeability as a
function of magnetic field strength.
handbook, halfpage
3F4
Pv
3
H (A/m) 10
200
10 2
3000
10
500
50
1000
30
1000
25
100
10
1
10
10 2
B (mT)
10
0
3
0
Fig.7
Fig.6
Specific power loss as a function of peak
flux density with frequency as a parameter.
2008 Sep 01
186
40
80
120
T (o C)
Specific power loss for several
frequency/flux density combinations
as a function of temperature.
Ferroxcube
Material specification
3F4
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
187