3f36 ver1.3.fm

FERROXCUBE
DATA SHEET
3F36
Material specification
2013 Jun 06
Ferroxcube
Material specification
3F36
3F36 SPECIFICATIONS
A medium to high frequency power material for use in
power and general purpose transformers at frequencies
of 0.5 - 1 MHz. Low power losses from 25 to 100 °C.
Especially suited for broad temperature range
applications like automotive, lighting and mobile
handheld.
ABW230
10 4
handbook, halfpage
3F36
µ's , µ''s
10 3
CONDITIONS
VALUE
µi
25 °C; ≤10 kHz; 0.25 mT
1 600 ± 20%
µa
100 °C; 25 kHz; 200 mT
≈ 2400
B
25 °C; 10 kHz; 1200 A/m
≈ 520
100 °C; 10 kHz;
1200 A/m
≈ 420
100 °C; 500 kHz; 50 mT
≈ 90
25 °C; 500 kHz; 100 mT
≈ 700
Pv
UNIT
10 2
mT
kW/m3
10
10 1
1
10
f (MHz)
100 °C; 500 kHz; 100 mT ≈ 700
≈ 12
Ωm
TC
≥ 230
°C
density
≈ 4750
kg/m3
ρ
DC; 25 °C
Fig.1
Complex permeability as
a function of frequency.
ABW255
handbook, halfpage
3F36
µi
25oC
100oC
500
ABW231
handbook, halfpage
3F36
B
(mT)
2000
400
300
1000
200
100
0
50
0
−50
50
Fig.2
2013 Jun 06
150
T (°C)
250
Initial permeability as a
function of temperature.
0
50
100
500
1000
H (A/m)
Fig.3 Typical B-H loops.
2
10 2
Ferroxcube
Material specification
3F36
ABW232
8000
25 oC
o
100 C
handbook, halfpage
µa
ABW233
10 4
handbook, halfpage
3F36
3F36
µ rev
6000
10 3
4000
10 2
2000
10
0
0
100
200
300
400
10 2
10
1
B (mT)
Fig.4
Amplitude permeability as
function of peak flux density.
Fig.5
3
H (A/m) 10
Reversible permeability as a
function of magnetic field strength.
ABW234
1M
Hz
kHz
10 4
handbook, halfpage
o
T = 100 C
ABW235
1200
handbook, halfpage
500
Pv
(kW/m 3)
3F36
3F36
Pv
(kW/m3)
^
f
B
(kHz) (mT)
900
10 3
500
100
600
10 2
300
1000
30
500
50
0
0
10
1
10
10 2
B (mT)
10
Fig.7
Fig.6
Specific power loss as a function of peak
flux density with frequency as a parameter.
2013 Jun 06
40
80
T (°C)
120
3
3
Specific power loss for several
frequency/flux density combinations
as a function of temperature.
Ferroxcube
Material specification
3F36
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2013 Jun 06
4