3C97 - Ferroxcube

FERROXCUBE
DATA SHEET
3C97
Material specification
2013 Jun 06
Ferroxcube
Material specification
3C97
3C97 SPECIFICATIONS
A low to medium frequency power material with low
power losses from 50 to 140 °C for use in power and
general purpose transformers at frequencies up to
0.5MHz. Especially suited for broad temperature range
applications like automotive.
10 4
handbook, halfpage
µ's , µ''s
3C97
µ's
10 3
SYMB
OL
CONDITIONS
VALUE
µi
25 °C; ≤10 kHz; 0.25 mT
3000 ± 20 %
µa
100 °C; 25 kHz; 200 mT
≈ 5000
B
25 °C; 10 kHz; 1200 A/m
≈ 530
100 °C; 10 kHz;
1200 A/m
≈ 410
60 °C; 100 kHz; 200 mT
≈ 320
PV
µ''s
UNIT
10 2
mT
kW/m3
10
10 1
120 °C; 100 kHz; 200 mT ≈ 320
1
10
2
f (MHz) 10
140 °C; 100 kHz; 200 mT ≈ 380
ρ
DC, 25 °C
≈5
Ωm
TC
≥ 215
°C
density
≈ 4 800
kg/m3
10000
handbook, halfpage
Fig.1
Complex permeability as
a function of frequency.
500
3C97
25 oC
100 oC
B
(mT)
µi
8000
400
6000
300
4000
200
2000
100
3C97
0
0
50
50
Fig.2
2013 Jun 06
150
T ( o C)
25
250
0
25
50
150
250
H (A/m)
Initial permeability as a
function of temperature.
Fig.3 Typical B-H loops.
181
Ferroxcube
Material specification
3C97
MFP126
8000
25 C
o
100 C
µa
MFP126
8000
o
handbook, halfpage
25 oC
o
100 C
handbook, halfpage
3C97
µa
6000
6000
4000
4000
2000
2000
3C97
0
0
0
100
200
300
0
400
100
200
Fig.4
300
400
B (mT)
B (mT)
Amplitude permeability as
function of peak flux density.
Fig.5
Reversible permeability as a
function of magnetic field strength.
800
104
handbook, halfpage
3C97
T = 100 °C
kHz
400
103
200
kHz
100
kHz
Pv
(kW/m3)
3C97
Pv
(kW/m 3 )
f
B
(kHz) (mT)
600
400
100
200
200
400
100
50
100
100
102
200
10
10
1
102
^
B (mT)
103
0
0
Fig.7
Fig.6
Specific power loss as a function of peak
flux density with frequency as a parameter.
2013 Jun 06
182
50
100
150
T (o C)
Specific power loss for several
frequency/flux density combinations
as a function of temperature.
Ferroxcube
Material specification
3C97
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2013 Jun 06
183