irfsx-0004_a_msm9169..

SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
SM9169 V3.X AP Writer User Manual
(1 to 1 Writer)
1. Introduction:
MSM9169 Writer can be use for programming all SyncMOS products(including
Flash and e-MCU , such as SM79xx,SM89xx,and SM59xx ).
2. Basic Operations:
MSM9169 Writer can operate in two modes :
2.1 On-line programming: used MSM9169 connect with PC which can download
program code into target IC.
2.2 Off-line programming: when PC download program code into writer’s
controller, offline programming can be achieved without PC via “Auto”
button .
Fig 1 MSM9169 Writer
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
1
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
3. Components:
3.1 MSM9169 board.
3.2 Windows 95/98/2000/XP OS.
3.3 DB-9 pin cable (for serial port) or USB To COM Port connector (for USB).
3.4 Writer application utility.
3.5 One power adapter +12V DC, connector (inside ”+”,outside ”-”).
4. Setup Procedure:
4.1 Copy MSM9169 application utility in your OS , then run SyncMOS Writer
Setup.exe which support Windows 95/98/2000/XP OS.
4.2 Use DB-9 pin cable to connect PC’s COM port and MSM9169’s RS232 Port.
4.3 Plug the 12 DC power adapter in to MSM9169’s DC Power Jack . Note : the
power adapter which plug in the writer is anode inside and negative pole
outside . Then the Power LED will light.
4.3 When MSM9169’s power LED is light , MSM9169 has ready to work.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
2
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
5. User Interface:
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
3
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
6. Update: Update Writer Timing
MSM9169 V3.x can update writer timing without modifying hardware.
6.1 Click “Update (ISP)” from Tools item.
6.2 Warning message for notice will come up.
6.3 Select target file for update.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
4
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
5
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
7. Connect:
7.1 After MSM9169 V3.x running, system will check connection with PC. If the
connection successful, a “Connect Success MSM9169 V3.x” message will
pop-up.
Connection Success
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
6
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
7.2 If connection fail, a “Connect Fail, No Respond” message will pop-up.
Connect Fail
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
7
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
8. Tool Bar Explanation:
8.1
Load: Load file for programming.
8.2
Save:Save buffer data to BIN format.
8.3
Edit:Edit and view buffer .
8.4
IC:Select IC type.
8.5
AUTO:Run selected function automatically.
8.6
Erase: Erase target IC’s Flash data.
8.7
Program: Write buffer data to target IC’s Flash.
8.8
Blank Check:Check target IC’s Flash being Erased or not.
8.9
Verify:Check target IC’s Flash content against buffer data.
8.10
Security:Force all Flash data being read as “0”.
8.11
Configure:Set ISP size(SM59xx only).
8.12
Send:Send data to MSM9169’s on-board controller for offline
programming.
8.13
Read:Read Target IC’s Flash data to buffer.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
8
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
9. Connect USB to COM Port:
9.1 When you connect USB to COM Port, you will get COM information form
“Control PanelÆSystemÆHardwareÆDevice Manager”.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
9
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
10
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
10. Re-connect with COM Port:
10.1 When connection has fail , please check connection of MSM9169 and PC. It
may have been connected to an incorrect COM Port.
10.2 If you want to reconnect MSM9169 with PC, you can select “COM Port”
from “Setting” item .
Reconnect COM Port
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
11
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
11. IC Type Selection:
You can select IC type for programming from tool bar.
Finish Select IC
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
12
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
12. Load File for Programming:
12.1 Select File\ Open( Load ) : Open file and load to Buffer.
12.2 If change IC type, please reload file.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
13
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
14
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
13. Edit Auto Function:
You can edit a sequence of functions to be executed with “Auto Function”
button。
13.1 Select “Edit Auto” from “Setting” menu.
13.2 An Auto Selection message box will show up, then you can choose which
function to execute。Push OK button to complete.
13.3 Double check the window which displays the functions you selected.
13.4 Push AUTO button on tool bar, then it will execute the functions that you
have selected.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
15
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
16
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
14. Display Programming Status:
14.1 Programming OK:
After you push AUTO button, MSM9169 will execute functions which you
selected. If the execution is successful, it will turn on green PASS light
accompanied with a short buzz.
14.2 Programming Fail:
If the execution fail, it will turn on red FAIL light accompanied with a long
buzz.
14.3 Program Timing:
After you push AUTO button, AUTO RUN START displays start time,
AUTO RUN END displays end time(If only single function executed, it
will not display time).
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
17
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
15. Configure Setting:
Set ISP size for SM59xx.
15.1 Select the “Conf.” button on tool bar.
15.2 Set Configure size.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
18
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
19
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
16. Read : Read Target IC Data
16.1 First click “Read” button, which will read Flash data from Target IC.
16.2 Click “Edit” to show data with a window.
16.3 In case of target IC being protected, all data will show “ 0 ” .
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
20
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
17. Send:(for Offline Programming)
MSM9169 support off-line programming, as below:
17.1 Push “Send” button, after you selected IC type and loaded file to buffer.
17.2 Then PC will download data to MSM9169 Controller MCU. MSM9169
board’s busy LED(Yellow) will lighted。After finish loading that the green
LED will lighted and a message of “Transmit Data to MCU => PASS” will
show on the message field, while the busy LED will turn off.
17.3 Push MSM9169 AUTO button, to start offline programming.
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
21
06/09/14
SyncMOS Technologies International, Inc.
MSM9169 Application Note
September 2006
For SyncMOS e-MCU Used
18. Notice:
18.1 Please don’t replace or remove any component from MSM9169 writer .
18.2 If it stops abnormally, please close MSM9169 V3.X Utility and reset board.
Then re-start MSM9169.
18.3 Make sure the target IC is place correctly, otherwise IC could be
permanently damaged.
18.4 If MSM9169 programming OK, it will show “PASS” message and a short
buzz。Meanwhile GOOD LED will light. If MSM9169 programming fail , it
will show “FAIL” message and a long buzz。Also, FAIL LED will light.
18.5 Please reload file for programming, after you change IC type.
18.6 If you want to install a new MSM9169 Utility, please uninstall the old
version first .
Specifications subject to change without notice, contact your sales representatives for the most recent information.
MSM9169 V7M1
22
06/09/14