Ordering information AC-DC Power Supplies Enclosed type PAA50F PAA PAA 1 50 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R -O High voltage pulse noise type : NAP series Low leakage current type : NAM series 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current J :Connector type N :with Cover R :with Remote ON/OFF *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA50F-3 30 3V 10A PAA50F-5 50 5V 10A PAA50F-12 51.6 12V 4.3A PAA50F-15 52.5 15V 3.5A PAA50F-24 52.8 24V 2.2A PAA50F-48 52.8 48V 1.1A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] INPUT FREQUENCY[Hz] EFFICIENCY[%] POWER FACTOR ACIN 100V ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE ON/OFF *3 INPUT-OUTPUT -RC INPUT-FG *3 OUTPUT-RC-FG *3 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD INRUSH CURRENT[A] OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * ACIN 100V ACIN 200V PAA50F-3 PAA50F-5 PAA50F-12 PAA50F-15 PAA50F-24 PAA50F-48 AC85 - 264 1f 0.5typ 0.8typ 0.25typ 0.4typ 50/60 (47 - 63) 67typ 74typ 77typ 78typ 80typ 80typ 0.95typ (Io=100%) 15typ (Io=100%) 15typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 48 10 10 4.3 3.5 2.2 1.1 20max 20max 48max 60max 96max 192max 40max 40max 100max 120max 150max 240max 80max 80max 120max 120max 120max 150max 140max 140max 160max 160max 160max 200max 120max 120max 150max 150max 150max 250max 160max 160max 180max 180max 180max 300max 50max 50max 120max 150max 240max 480max 60max 60max 150max 180max 290max 600max 20max 20max 48max 60max 96max 192max 500max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%) 2.85 - 3.6 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Optional (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 37X85X159mm (without terminal block) (WXHXD) /400g max (without cover) Convection According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Applicable when Remote ON/OFF(optional) is added. Please contact us about safety approvals for the model with option. Derating is required when operated with case cover. PAA-2 PAA50F PAA External view CN3 Connector for Remote ON/OFF (option) CN3 Connector for Remote ON/OFF (option) LED 15max Voltage adjust (12) Cover name plate 159 Name plate 1 2 12 Cover(option) CN2 (24) 1 RC(+) 2 RC(-) ( 3.5 20 º4 Name plate 2-º3.5 ( 7.5 4 143 2537 Barrier strip type Model B2B-XH-A Mating Connector(Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 11 127-+0.5 3.5 Connector type Contents 21.5 171 ¶Weight: 400g or less(without cover) ¶Cover is optional +1 ¶Tolerance - Pin No. 100-+0.5 159 M3 I/O Connector Mating Connector Terminal CN1 10-31-1048 10-63-3044 Chain: 08-70-1031 Loose: 08-70-1030 CN2 09-65-2049 09-50-1043 Chain: 08-70-1031 Loose: 08-70-1030 ¶Maximum 5A per pin of CN2 can be applied. (Mfr : Molex) CN3 Option (Mfr : J.S.T.) 85 38.5 Terminal cover (15) 3.5 FG AC(L) NC AC(N) 18.5 CN1 2-M3 Mounting hole (71) (65) (13.5) 7.5 9.5 + FG AC(L) AC(N) - 8.5 + 3-M3 Mounting hole ¶Mounting torque:0.49N.m(5.0kgf.cm)max Performance data ¡RISE TIME & FALL TIME (PAA50F-5) ¡EFFICIENCY (PAA50F-5) 84 80 76 EFFICIENCY 72 DC Output ACIN 100V Io=100% AC Input 68 64 60 56 Load factor 100% Load factor 50% 52 0 50ms/DIV 100 140 180 220 INPUT VOLTAGE ¡HARMOINC CURRENT (PAA50F-5) 10 Load factor 100% Input voltage AC 230V A A 100% Load factor Input voltage AC 100V 1 HARMONIC CURRENT 1 HARMONIC CURRENT 300 ¡HARMONIC CURRENT (PAA50F-5) 10 Harmonic current standard class D (at odd number) 0.1 0.01 0.001 0 260 V 10 20 HARMONIC ORDER 30 40 Harmonic current standard class D (at odd number) 0.1 0.01 0.001 0 10 20 30 40 HARMONIC ORDER PAA-3 Ordering information AC-DC Power Supplies Enclosed type PAA75F PAA PAA 1 75 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R -O High voltage pulse noise type : NAP series Low leakage current type : NAM series 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current J :Connector type N :with Cover R :with Remote ON/OFF *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA75F-3 45 3V 15A PAA75F-5 75 5V 15A PAA75F-12 75.6 12V 6.3A PAA75F-15 75 15V 5A PAA75F-24 76.8 24V 3.2A PAA75F-48 76.8 48V 1.6A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] INPUT FREQUENCY[Hz] EFFICIENCY[%] POWER FACTOR ACIN 100V ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE ON/OFF *3 INPUT-OUTPUT -RC INPUT-FG *3 OUTPUT-RC-FG *3 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD INRUSH CURRENT[A] OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * ACIN 100V ACIN 200V PAA75F-3 PAA75F-5 PAA75F-12 PAA75F-15 PAA75F-24 PAA75F-48 AC85 - 264 1f 0.7typ 1.2typ 0.35typ 0.6typ 50/60 (47 - 63) 67typ 74typ 77typ 78typ 80typ 80typ 0.95typ (Io=100%) 15typ (Io=100%) 15typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 48 15 15 6.3 5 3.2 1.6 20max 20max 48max 60max 96max 192max 40max 40max 100max 120max 150max 240max 80max 80max 120max 120max 120max 150max 140max 140max 160max 160max 160max 200max 120max 120max 150max 150max 150max 250max 160max 160max 180max 180max 180max 300max 50max 50max 120max 150max 240max 480max 60max 60max 150max 180max 290max 600max 20max 20max 48max 60max 96max 192max 500max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%) 2.85 - 3.6 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Optional (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 42X93X175mm (without terminal block) (WXHXD) /550g max (without cover) Convection According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Applicable when Remote ON/OFF(optional) is added. Please contact us about safety approvals for the model with option. Derating is required when operated with case cover. PAA-4 PAA75F PAA External view CN3 Connector for Remote ON/OFF(option) CN3 Connector for Remote ON/OFF(option) LED Voltage adjust 15max Cover name plate (12) Name plate 1 2 12 Cover(option) CN2 FG AC(L) NC AC(N) 45 CN1 2-M3 Mounting hole (78) (71) (13.5) 7.5 9.5 + FG AC(L) AC(N) + Terminal cover (15) (24) 93 175 125-+0.5 175 M3 20 187 CN3 Option (Mfr : J.S.T.) Pin No. Contents 1 RC(+) 2 RC(-) Name plate 2-º3.5 7.5 Model B2B-XH-A Mating Connector(Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 ( ( 3.5 20 º4 5 159 3042 Barrier strip type 21 Connector type 11 ¶Weight: 500g or less(without cover) ¶Cover is optional ¶Tolerance+ -1 35 125-+0.5 3.5 3.5 I/O Connector Mating Connector Terminal CN1 10-31-1048 10-63-3044 Chain: 08-70-1031 Loose: 08-70-1030 CN2 09-65-2069 09-50-1063 Chain: 08-70-1031 Loose: 08-70-1030 ¶Maximum 5A per pin of CN2 can be applied. (Mfr : Molex) 3-M3 Mounting hole ¶Mounting torque:0.49N.m(5.0kgf.cm)max Performance data ¡RISE TIME & FALL TIME (PAA75F-5) ¡EFFICIENCY (PAA75F-5) 84 80 76 EFFICIENCY 72 DC Output ACIN 100V Io=100% AC Input 68 64 60 56 Load factor 100% Load factor 50% 52 0 50ms/DIV 100 140 180 INPUT VOLTAGE ¡HARMOINC CURRENT (PAA75F-5) HARMONIC CURRENT Harmonic current standard class D (at odd number) 0.1 0.01 10 20 HARMONIC ORDER 30 100% Load factor Input voltage AC 230V A A HARMONIC CURRENT 300 10 100% Load factor Input voltage AC 100V 0.001 0 260 ¡HARMONIC CURRENT (PAA75F-5) 10 1 220 V 40 1 Harmonic current standard class D (at odd number) 0.1 0.01 0.001 0 10 20 30 40 HARMONIC ORDER PAA-5 Ordering information AC-DC Power Supplies Enclosed type PAA100F PAA PAA 100 1 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R -O High voltage pulse noise type : NAP series Low leakage current type : NAM series 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current N :with Cover R :with Remote ON/OFF *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA100F-3 60 3V 20A PAA100F-5 100 5V 20A PAA100F-12 102 12V 8.5A PAA100F-15 105 15V 7A PAA100F-24 108 24V 4.5A PAA100F-48 100.8 48V 2.1A PAA100F-3 PAA100F-5 PAA100F-12 PAA100F-15 AC85 - 264 1f or DC120 - 340 0.9typ 1.4typ 0.45typ 0.7typ 50/60 (47 - 63) 65typ 74typ 76typ 77typ 0.99typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) (At cold start) 40typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 20 20 8.5 7 20max 20max 48max 60max 40max 40max 100max 120max 80max 80max 120max 120max 140max 140max 160max 160max 120max 120max 150max 150max 160max 160max 180max 180max 50max 50max 120max 150max 60max 60max 150max 180max 20max 20max 48max 60max 500max (ACIN 85V, Io=100%) 20typ (Io=100%) PAA100F-24 PAA100F-48 79typ 79typ 24 4.5 96max 150max 120max 160max 150max 180max 240max 290max 96max 48 2.1 192max 240max 150max 200max 400max 600max 480max 600max 192max SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * ACIN 100V ACIN 200V FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF *3 INPUT-OUTPUT -RC INPUT-FG *3 OUTPUT-RC-FG *3 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD 2.85 - 3.6 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Provided Optional (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 50X93X189mm (without terminal block) (WXHXD) /700g max (without cover) Convection According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Applicable when Remote ON/OFF(optional) is added. Please contact us about safety approvals for the model with option. Derating is required when operated with cover. PAA-6 PAA100F PAA External view Voltage adjust LED Short piece (13.5) CN1(option) 20max Cover name plate 189 1 2 Cover (option) 10 2-M4 Mounting hole 8.2 +V (81) -V 93 +S -S 45 FG AC(L) (11.5) AC(N) M4 (16) (28) Terminal cover 125-+0.5 20 º4.5 74 4.5 Contents +RC -RC 10 37.5 Mating Connector(Terminal) Mfr: J.S.T. XHP-2(BXH-001T-P0.6 or SXH-001T-P0.6) 22.5 Pin No. 1 2 100-+0.5 25-+0.5 50 <Optional> ¶CN1(Connector for Remote ON/OFF) Model: B2B-XH-A 3-M4 Mounting hole ¶Weight: 700g or less(without cover) ¶Cover is optional ¶Tolerance + -1 ¶Mounting torque:1.2N . m(12.8kgf . cm)max Name plate 5.5 Performance data ¡RISE TIME & FALL TIME (PAA100F-5) ¡EFFICIENCY (PAA100F-5) 80 78 EFFICIENCY 76 DC Output AC Input ACIN 100V Io=100% 74 72 70 68 60 50ms/DIV Load factor100% Load factor 50% 100 140 180 INPUT VOLTAGE ¡HARMOINC CURRENT (PAA100F-5) 300 10 HARMONIC CURRENT 1 100% Load factor Input voltage AC 100V 0.1 0.01 10 20 HARMONIC ORDER 30 Harmonic current standard class A (at odd number) A Harmonic current standard class A (at odd number) A HARMONIC CURRENT 260 V ¡ HARMONIC CURRENT (PAA100F-5) 10 0.001 0 220 40 1 100% Load factor Input voltage AC 230V 0.1 0.01 0.001 0 10 20 30 40 HARMONIC ORDER PAA-7 Ordering information AC-DC Power Supplies Enclosed type PAA150F PAA PAA 150 1 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R -O High voltage pulse noise type : NAP series Low leakage current type : NAM series 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current N :with Cover R :with Remote ON/OFF *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA150F-3 90 3V 30A PAA150F-5 150 5V 30A PAA150F-12 156 12V 13A PAA150F-15 150 15V 10A PAA150F-24 156 24V 6.5A PAA150F-48 158.4 48V 3.3A PAA150F-3 PAA150F-5 PAA150F-12 PAA150F-15 AC85 - 264 1f or DC120 - 340 1.4typ 2.0typ 0.7typ 1.0typ 50/60 (47 - 63) 67typ 75typ 78typ 80typ 0.99typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) (At cold start) 40typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 30 30 13 10 20max 20max 48max 60max 40max 40max 100max 120max 80max 80max 120max 120max 140max 140max 160max 160max 120max 120max 150max 150max 160max 160max 180max 180max 50max 50max 120max 150max 60max 60max 150max 180max 20max 20max 48max 60max 500max (ACIN 85V, Io=100%) 20typ (Io=100%) PAA150F-24 PAA150F-48 81typ 81typ 24 6.5 96max 150max 120max 160max 150max 180max 240max 290max 96max 48 3.3 192max 240max 150max 200max 400max 600max 480max 600max 192max SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * ACIN 100V ACIN 200V FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF *3 INPUT-OUTPUT -RC INPUT-FG *3 OUTPUT-RC-FG *3 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD 2.85 - 3.6 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Provided Optional (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +65C, 10 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 10 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 65X93X199mm (without terminal block) (WXHXD) /900g max (without cover) Convection According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Applicable when Remote ON/OFF(optional) is added. Please contact us about safety approvals for the model with option. Derating is required when operated with cover. PAA-8 PAA150F PAA External view CN1(option) Short piece Cover name plate Voltage adjust (18.5) LED 20max 199 1 2 10 +S (81) 50-+0.5 93 4-M4 Mounting hole 8.2 +V +V -V -V FG AC(L) AC(N) -S (21.5) (12.5) (43.5) (11.5) 21 Cover (option) Terminal cover M4 125-+0.5 40 º4.5 100-+0.5 Contents +RC -RC 37.5 Mating Connector(Terminal) Mfr: J.S.T. XHP-2(BXH-001T-P0.6 or SXH-001T-P0.6) 4.5 25 -+0.5 65 3-M4 Mounting hole 25 Pin No. 1 2 80 8 <Optional> ¶CN1(Connector for Remote ON/OFF) Model: B2B-XH-A ¶Weight: 900g or less(without cover) ¶Cover is optional ¶Tolerance+ -1 ¶Mounting torque:1.2N . m(12.8kgf . cm)max Name plate 7.5 Performance data ¡RISE TIME & FALL TIME (PAA150F-5) ¡EFFICIENCY (PAA150F-5) 80 EFFICIENCY 78 DC Output ACIN 100V Io=100% AC Input 76 74 Load factor100% Load factor 50% 72 60 50ms/DIV 220 260 300 V 10 A Harmonic current standard class A(at odd number) Load factor 100% Input voltage AC 100V 1 HARMONIC CURRENT A 180 ¡INPUT HARMONIC CURRENT (PAA150F-5) 10 HARMONIC CURRENT 140 INPUT VOLTAGE ¡HARMOINC CURRENT (PAA150F-5) 0.1 0.01 0.001 0 100 10 20 HARMONIC ORDER 30 40 1 Harmonic current standard class A(at odd number) Load factor 100% Input voltage AC 230V 0.1 0.01 0.001 0 10 20 30 40 HARMONIC ORDER PAA-9 Ordering information AC-DC Power Supplies Enclosed type PAA300F PAA PAA 300 1 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-10-472 R -O High voltage pulse noise type : NAP series Low leakage current type : NAM series 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *3 C :with Coating G :Low leakage current R :Positive logic control W :with Alarm signal *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA300F-3 180 3V 60A PAA300F-5 300 5V 60A PAA300F-12 324 12V 27A PAA300F-15 330 15V 22A PAA300F-24 336 24V 14A PAA300F-48 336 48V 7A PAA300F-3 PAA300F-5 PAA300F-12 PAA300F-15 AC85 - 264 1f or DC120 - 340 2.6typ 4.4typ 1.3typ 2.2typ 50/60 (47 - 63) 68typ 74typ 78typ 80typ 0.99typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) 40typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 60 60 27 22 20max 20max 48max 60max 40max 40max 100max 120max 80max 80max 120max 120max 140max 140max 160max 160max 120max 120max 150max 150max 160max 160max 180max 180max 40max 50max 120max 150max 50max 60max 150max 180max 12max 20max 48max 60max 500max (ACIN 85V, Io=100%) 20typ (Io=100%) PAA300F-24 PAA300F-48 81typ 81typ 24 14 96max 150max 120max 160max 150max 180max 240max 290max 96max 48 7 192max 300max 150max 200max 200max 300max 480max 580max 192max SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 * ACIN 100V ACIN 200V FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC INPUT-FG OUTPUT-RC-FG OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD 2.85 - 3.45 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Provided Provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 50MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 120X92X190mm (without terminal block and screw) (WXHXD) /2.2kg max Forced cooling (internal fan) According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. PAA-10 PAA300F PAA External view M5 M4 8 FG hole M4 6.6 70-+0.5 100-+0.5 120 10 25 V.ADJ Short piece 150-+0.5 190 Voltage adjust 79 LED 10 + 8.6 Name plate Output terminal(-) Output (+) terminal 8-M4(Bottom) 106 - AC(L) AC(N) FG -S +S CB VB RG RC 20 28max Terminal cover 19.5 (Top) 92 AIR FLOW 21 12 38.5 15.5 50-+0.5 4-M4 (Both sides) 76 9 28 ¶+,-Terminal details 150-+0.5 20 (Bottom) 7max ¶Weight: 2.2kg or less ¶Tolerance + -1 ¶Mounting torque:1.5N . m(16kgf . cm)max Performance data ¡RISE TIME & FALL TIME ¡EFFICIENCY (PAA300F-5) (PAA300F-5) 80 78 EFFICIENCY 76 DC Output AC Input ACIN 100V Io=100% 74 72 Load factor100% Load factor 50% 70 0 50ms/DIV 100 140 180 220 INPUT VOLTAGE ¡HARMOINC CURRENT (PAA300F-5) 10 A Harmonic current standard class A,D(at odd number) Load factor 100% Input voltage AC 100V 1 HARMONIC CURRENT A HARMONIC CURRENT 300 ¡INPUT HARMONIC CURRENT (PAA300F-5) 10 0.1 0.01 0.001 0 260 V 10 20 HARMONIC ORDER 30 40 Harmonic current standard class A,D(at odd number) 1 Load factor 100% Input voltage AC 230V 0.1 0.01 0.001 0 10 20 30 40 HARMONIC ORDER PAA-11 Ordering information AC-DC Power Supplies Enclosed type PAA600F PAA PAA 600 1 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-16-472 R -O High voltage pulse noise type : NAP series Low leakage current type : NAM series 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *3 C :with Coating G :Low leakage current R :Positive logic control W :with Alarm signal *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PAA600F-3 360 3V 120A PAA600F-5 600 5V 120A PAA600F-12 636 12V 53A PAA600F-15 645 15V 43A PAA600F-24 648 24V 27A PAA600F-48 624 48V 13A PAA600F-3 PAA600F-5 PAA600F-12 PAA600F-15 AC85 - 264 1f or DC120 - 340 5.4typ 8.2typ 2.7typ 4.1typ 50/60 (47 - 63) 70typ 76typ 80typ 81typ 0.99typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) 40typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 120 120 53 43 20max 20max 48max 60max 40max 40max 100max 120max 80max 80max 120max 120max 140max 140max 160max 160max 120max 120max 150max 150max 160max 160max 180max 180max 40max 50max 120max 150max 50max 60max 150max 180max 12max 20max 48max 60max 500max (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) PAA600F-24 PAA600F-48 83typ 83typ 24 27 96max 150max 120max 160max 150max 180max 240max 290max 96max 48 13 192max 300max 150max 200max 200max 300max 480max 580max 192max SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 * ACIN 100V ACIN 200V FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC INPUT-FG OUTPUT-RC-FG OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD 2.85 - 3.45 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Provided Provided AC3,000V 1minute, Cutoff current = 10mA max,DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA max,DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA max,DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA max,DC100V 50MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 190X92X200mm (without terminal block and screw) (WXHXD) /4.0kg max Forced cooling (internal fan) According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. PAA-12 PAA600F PAA External view 4-M4(Top) 200 M4 Name plate Short piece 45 10 10 6.6 5 170-+0.5 190 100-+0.5 12 15.5 Output terminal(+) 9 V.ADJ 9 Output terminal(-) 55 8.6 118 125 FG hole M4 100-+0.5 10 AC(L) AC(N) FG RG RC CB VB -S -M +M +S Output voltage adjust LED 28max 19.5 15 20 (Top) 4-M4 75.5 47.5 Terminal cover 8-M4(Bottom) 150-+0.5 160-+0.5 AIR FLOW 16 (Both sides) 92 M5 60-+0.5 79.5 160-+0.5 20 ¶Weight: 4.0kg or less ¶Tolerance + -1 7max (Bottom) ¶Mounting torque:1.5N . m(16kgf . cm)max Performance data ¡RISE TIME & FALL TIME ¡EFFICIENCY (PAA600F-5) (PAA600F-5) 82 80 EFFICIENCY 78 DC Output AC Input ACIN 100V Io=100% 76 74 Load factor 100% Load factor 50% 72 70 0 50ms/DIV 100 140 180 220 INPUT VOLTAGE ¡HARMOINC CURRENT (PAA600F-5) 260 300 V ¡HARMONIC CURRENT (PAA600F-5) 10 10 Harmonic current standard class A,D(at odd number) A HARMONIC CURRENT HARMONIC CURRENT A Load factor 100% Input voltage AC 100V 1 0.1 0.01 0.001 0 10 20 HARMONIC ORDER 30 40 1 Harmonic current standard class A,D(at odd number) Load factor 100% Input voltage AC 230V 0.1 0.01 0.001 0 10 20 30 40 HARMONIC ORDER PAA-13