"VUIPSJ[FE%JTUSJCVUPS5PUBM1PXFS*OUFSOBUJPOBM*OD5PMM'SFF 64 1) XXXUPUBMQPXFSDPN Ordering information AC-DC Power Supplies Enclosed type PLA300F PLA PL 1 A 2 300 3 F 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. -O 5 -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *7 C : with Coating G: Low leakage current V : External potentiometer for output voltage adjustment U : Low input voltage stop (Complies with SEMI F-47) R : Remote on/off (Required external power source) F4: Low speed fan T2: Horizontal terminal block (Not screw hold type) Refer to instruction manual 5.1 about optional. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V INPUT ACIN 230V ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -10 to 0C OUTPUT 0 to +50C RIPPLE NOISE[mVp-p] *1 -10 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *10 INPUT-OUTPUT RC INPUT-FG ISOLATION *10 OUTPUT RC-FG *10 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *9 EFFICIENCY[%] PLA-12 PLA300F-5 PLA300F-12 PLA300F-15 PLA300F-24 PLA300F-36 PLA300F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to instruction manual 1.1 and 3.2) *3 (DC input and AC265 - 277V input *3) 3.1typ (Io=90%) 3.4typ (Io=90%) 3.0typ (Io=100%) 3.3typ (Io=100%) 1.5typ (Io=100%) 1.7typ (Io=100%) 50 / 60 (47 - 63) (DC input and 440Hz *3) 73typ (Io=90%) 78typ (Io=90%) 80typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) 74typ (Io=100%) 78typ (Io=100%) 80typ (Io=100%) 84typ (Io=100%) 84typ (Io=100%) 84typ (Io=100%) 77typ (Io=100%) 81typ (Io=100%) 83typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=90%) Ta=25C at cold start 20typ (Io=100%) Ta=25C at cold start 40typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 5 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 50 25 20 12.5 8.4 6.3 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 250 300 300 300 302.4 302.4 20max 48max 60max 96max 144max 192max 40max 100max 120max 150max 150max 300max 80max 120max 120max 120max 150max 150max 140max 160max 160max 160max 160max 400max 120max 150max 150max 150max 200max 200max 160max 180max 180max 180max 240max 500max 50max 120max 150max 240max 360max 480max 75max 180max 180max 290max 440max 600max 20max 48max 60max 96max 144max 192max 300typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A "VUIPSJ[FE%JTUSJCVUPS5PUBM1PXFS*OUFSOBUJPOBM*OD5PMM'SFF 64 1) XXXUPUBMQPXFSDPN PLA300F PLA SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY OTHERS 102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max Forced cooling (internal fan) 5-year (Depends on the used condition) *8 *6 *1 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). Please refer to the instruction manual 1.6. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Derating is required. As for DC input, 440Hz input and AC265 to 277V input, please contact us. *4 Please contact us about dynamic load and input response. *5 Derating is required. Please refer to instruction manual 3.2. *6 As for detail condition, please refer to instruction manual 3.3. *7 Please contact us about safety approvals for the model with option. *8 Fan speed is changed by load factor. *9 Please contact us about other class. *10 RC terminal is applied at option -R. And RC terminal is isolated from input, output and FG. * To meet the specifications, do not operate over-loaded condition. * Parallel operation is not possible. * A sound may occur from power supply at peak loading. Features - Economical model - Long lifetime (Refer to instruction manual) - Low profile (41mm, 1.61 inch = meet to 1U height) - Wide temperature range (-20 to +70 Refer to instruction manual) - Screw hold type terminal block - Fan speed control (At no load condition) - Various option - Complies with SEMI F-47 (Option-U: Refer to instruction manual) Block diagram FUSE 250V 10A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG CURRENT SENSING BOOSTER INDUCTOR RECTIFIER AND FILTER CURRENT SENSING CONTROL CONTROL OVER VOLTAGE PROTECTION INVERTER INVERTER RECTIFIER AND FILTER THERMAL PROTECTION THREE TERMINAL REGULATOR CONTROL DC OUT FAN External view External size of option V, option R and option T2 is different from standard model, and refer to ”5. Option and Others” of instruction manual for detail. ±1.5 16.6 [0.65] 13.42 ±1.5 (LED) [0.53] 102 [0.2max] 150 ±0.5 [0.77] [5.91] AIR FLOW [1.61] [0.98] 5max [7.48] 25 ±0.5 190 19.5 [4.02] [2.36] 60 ±0.5 [5.91] [0.77] 19.5 150 ±0.5 [0.49] 10.5 ¶ Tolerance : ±1 [±0.04] ¶ Weight : 1.0kg max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Aluminum ¶ Case material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 1.2N m max ¶ Screw tightening torque : 1.6N m max ¶ Please connect safety ground to FG terminal on the unit. 12.5 [0.41] 5.7 [0.22] 10 AC AC (N) (L) M4 4-M4 Mounting Hole (Bottom side) 41 [0.78] Name plate [0.79max] [0.39] [0.49] 19.8 ±1.5 12.5 ±1.5 20max -V FG FG( ) AC(N) AC(L) +V +V -V Output terminal (-) V.ADJ Output terminal (+) 5.75 ±1.5 Output voltage adjustable potentiometer (potentiometer) [0.23] LED ±1.5 8.6 [0.52] [0.34] 13.1 4-M4 Mounting Hole PLA-13