PLA300F - Total Power International

"VUIPSJ[FE%JTUSJCVUPS5PUBM1PXFS*OUFSOBUJPOBM*OD5PMM'SFF 64
1)
XXXUPUBMQPXFSDPN
Ordering information
AC-DC Power Supplies Enclosed type
PLA300F
PLA
PL
1
A
2
300
3
F
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
to connect with several devices.
-O
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *7
C : with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
U : Low input voltage stop
(Complies with SEMI F-47)
R : Remote on/off
(Required external power source)
F4: Low speed fan
T2: Horizontal terminal block
(Not screw hold type)
Refer to instruction manual 5.1
about optional.
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 115V
ACIN 230V
FREQUENCY[Hz]
ACIN 100V
ACIN 115V
INPUT
ACIN 230V
ACIN 100V
POWER FACTOR
ACIN 115V
ACIN 230V
ACIN 100V
INRUSH CURRENT[A] ACIN 115V
ACIN 230V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 85-115V
CURRENT[A]
ACIN 115V-264V
ACIN 85-115V
WATTAGE[W]
ACIN 115V-264V
*4
LINE REGULATION[mV]
LOAD REGULATION[mV] *4
0 to +50C
RIPPLE[mVp-p]
*1
-10 to 0C
OUTPUT
0 to +50C
RIPPLE NOISE[mVp-p]
*1
-10 to 0C
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
*10
INPUT-OUTPUT RC
INPUT-FG
ISOLATION
*10
OUTPUT RC-FG
*10
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE *5
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR *9
EFFICIENCY[%]
PLA-12
PLA300F-5
PLA300F-12
PLA300F-15
PLA300F-24
PLA300F-36
PLA300F-48
AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to instruction manual 1.1 and 3.2) *3
(DC input and AC265 - 277V input *3)
3.1typ (Io=90%)
3.4typ (Io=90%)
3.0typ (Io=100%) 3.3typ (Io=100%)
1.5typ (Io=100%) 1.7typ (Io=100%)
50 / 60 (47 - 63) (DC input and 440Hz *3)
73typ (Io=90%)
78typ (Io=90%)
80typ (Io=90%)
84typ (Io=90%)
84typ (Io=90%)
84typ (Io=90%)
74typ (Io=100%)
78typ (Io=100%)
80typ (Io=100%)
84typ (Io=100%)
84typ (Io=100%)
84typ (Io=100%)
77typ (Io=100%)
81typ (Io=100%)
83typ (Io=100%)
87typ (Io=100%)
87typ (Io=100%)
87typ (Io=100%)
0.98typ (Io=90%)
0.98typ (Io=100%)
0.95typ (Io=100%)
20typ (Io=90%) Ta=25C at cold start
20typ (Io=100%) Ta=25C at cold start
40typ (Io=100%) Ta=25C at cold start
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
5
12
15
24
36
48
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
50
25
20
12.5
8.4
6.3
Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
250
300
300
300
302.4
302.4
20max
48max
60max
96max
144max
192max
40max
100max
120max
150max
150max
300max
80max
120max
120max
120max
150max
150max
140max
160max
160max
160max
160max
400max
120max
150max
150max
150max
200max
200max
160max
180max
180max
180max
240max
500max
50max
120max
150max
240max
360max
480max
75max
180max
180max
290max
440max
600max
20max
48max
60max
96max
144max
192max
300typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
4.50 to 5.50
10.80 to 13.20
13.50 to 16.50
21.60 to 26.40
32.40 to 39.60
43.20 to 52.80
5.00 to 5.15
12.00 to 12.48
15.00 to 15.60
24.00 to 24.96
36.00 to 37.44
48.00 to 49.92
Works over 105% of rating and recovers automatically
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
41.40 to 50.40
55.20 to 67.20
LED (Green)
Not provided
Optional (Required external power source. Option -R)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
-20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
196.1m/s2 (20G), 11ms, once each X, Y and Z axes
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
"VUIPSJ[FE%JTUSJCVUPS5PUBM1PXFS*OUFSOBUJPOBM*OD5PMM'SFF 64
1)
XXXUPUBMQPXFSDPN
PLA300F
PLA
SPECIFICATIONS
CASE SIZE/WEIGHT
COOLING METHOD
WARRANTY WARRANTY
OTHERS
102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max
Forced cooling (internal fan)
5-year (Depends on the used condition)
*8
*6
*1 This is the value that measured on measuring board with capacitor
of 22mF and 0.1mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
Please refer to the instruction manual 1.6.
*2 Drift is the change in DC output for an eight hour period after a
half-hour warm-up at 25C.
*3 Derating is required. As for DC input, 440Hz input and AC265 to
277V input, please contact us.
*4 Please contact us about dynamic load and input response.
*5 Derating is required. Please refer to instruction manual 3.2.
*6 As for detail condition, please refer to instruction manual 3.3.
*7 Please contact us about safety approvals for the model with option.
*8 Fan speed is changed by load factor.
*9 Please contact us about other class.
*10 RC terminal is applied at option -R. And RC terminal is
isolated from input, output and FG.
* To meet the specifications, do not operate over-loaded
condition.
* Parallel operation is not possible.
* A sound may occur from power supply at peak loading.
Features
- Economical model
- Long lifetime (Refer to instruction manual)
- Low profile (41mm, 1.61 inch = meet to 1U height)
- Wide temperature range (-20
to +70
Refer to instruction manual)
- Screw hold type terminal block
- Fan speed control (At no load condition)
- Various option
- Complies with SEMI F-47 (Option-U: Refer to instruction manual)
Block diagram
FUSE
250V 10A
NOISE
FILTER
AC IN 85 - 264V
INRUSH
CURRENT
LIMIT
RECTIFIER
FG
CURRENT
SENSING
BOOSTER
INDUCTOR
RECTIFIER
AND
FILTER
CURRENT
SENSING
CONTROL
CONTROL
OVER VOLTAGE
PROTECTION
INVERTER
INVERTER
RECTIFIER
AND
FILTER
THERMAL
PROTECTION
THREE
TERMINAL
REGULATOR
CONTROL
DC OUT
FAN
External view
External size of option V, option R and option T2 is different from standard model, and refer to ”5. Option and Others” of instruction manual for detail.
±1.5
16.6
[0.65]
13.42 ±1.5 (LED)
[0.53]
102
[0.2max]
150 ±0.5
[0.77]
[5.91]
AIR FLOW
[1.61]
[0.98]
5max
[7.48]
25 ±0.5
190
19.5
[4.02]
[2.36]
60 ±0.5
[5.91]
[0.77]
19.5
150 ±0.5
[0.49]
10.5
¶ Tolerance : ±1 [±0.04]
¶ Weight : 1.0kg max
¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches]
¶ Chassis material : Aluminum
¶ Case material : Electric galvanizing steel board
¶ Dimensions in mm, [ ]=inches
¶ Mounting torque : 1.2N m max
¶ Screw tightening torque : 1.6N m max
¶ Please connect safety ground to FG terminal on the unit.
12.5
[0.41]
5.7
[0.22]
10
AC AC
(N) (L)
M4
4-M4
Mounting Hole
(Bottom side)
41
[0.78]
Name plate
[0.79max]
[0.39]
[0.49]
19.8 ±1.5
12.5 ±1.5
20max
-V FG
FG( )
AC(N)
AC(L)
+V +V -V
Output terminal (-)
V.ADJ
Output terminal (+)
5.75 ±1.5
Output voltage
adjustable potentiometer
(potentiometer)
[0.23]
LED
±1.5
8.6
[0.52]
[0.34]
13.1
4-M4
Mounting Hole
PLA-13