Ordering information AC-DC Power Supplies Enclosed type ADA600F ADA 600 1 2 F 3 -24 4 Recommended EMI/EMC Filter NAC-20-472 R ADA High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *7 G :Low leakage current E :Low leakage current and EMI class A F :with Fan unit T :Vertical terminal block J :Connector type C :with Coating R :Remote ON/OFF N1:DIN rail W:Alarms and Redundant operation Specification is changed at option,refer to Instruction Manual. Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air. SPECIFICATIONS MODEL VOLTAGE[V] FREQUENCY[Hz] ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V *1 INRUSH CURRENT[A] ACIN 200V *1 LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V *2 ACIN 100V *2 CURRENT[A] ACIN 200V *2 ACIN 200V *2 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *3 RIPPLE[mVp-p] -10 - 0C *3 0 to +50C *3 RIPPLE NOISE[mVp-p] -10 - 0C *3 TEMPERATURE REGULATION[mV] 0 to +50C *4 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION ALARM OUTPUT REMOTE ON/OFF(RC) *5 INPUT-OUTPUT -RC INPUT-FG *5 OUTPUT-RC-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ADA600F-24 ADA600F-30 ADA600F-36 ADA600F-48 AC85 - 264 1f or DC 120 - 350 (AC64 or DC90 optionally available *6) 50/60 (47 - 63) or DC 84typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 89typ (Io=100%) 0.99typ (Io=100%) 0.98typ (Io=100%) 20typ (Io=100%) (More than 3sec.to re-start) 40typ (Io=100%) (More than 3sec.to re-start) 0.75max (60Hz, According to IEC60950 and DEN-AN) (Io=100%) 24 30 36 48 14 (Peak 25) convection 11 (Peak 20) convection 9 (Peak 16.5) convection 6.5 (Peak 12.5) convection 21 (Peak 25) forced air 16.5 (Peak 20) forced air 14 (Peak 16.5) forced air 10.5 (Peak 12.5) forced air 15 (Peak 31) convection 12 (Peak 24.5) convection 10 (Peak 20.5) convection 7 (Peak 15.5) convection 25 (Peak 31) forced air 20 (Peak 24.5) forced air 16.5 (Peak 20.5) forced air 12.5 (Peak 15.5) forced air 96max 120max 144max 192max 150max 180max 240max 300max 120max 160max 200max 200max 160max 230max 260max 300max 150max 190max 230max 250max 180max 250max 280max 400max 240max 300max 360max 480max 96max 120max 144max 192max 500max (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.6 - 27.0 27.0 - 33.0 33.0 - 41.0 41.0 - 52.8 23.5 - 24.5 29.0 - 31.0 35.0 - 37.0 47.0 - 49.0 Works over 101% of peak current and recovers automatically 31 - 34.5 40 - 48 51 - 60 64 - 76 LED (Green) Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5) Requirement for external source (Option : -R, refer to Instruction Manual 5) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +71C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input) Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 *8 65X127X195mm [2.56X5X7.68 inches] (WXHXD) (without terminal block) /1.5kg max Convection/Forced air *1 The value is primary surge.The current of input surge to a built-in EMI/EMC Filter (0.2ms or less) is excluded. *2 Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown in Instruction Manual 2.3. *3 This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM101). ADA-2 *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *5 Applicable when remote control (optional) is added. *6 Derating is required.Consult us for details. *7 Please contact us about safety approvals for the model with option. *8 Please contact us about class C. * A sound may occur from power supply at pulse loading. ADA600F Block diagram Fuse 250V12A Booster inductor Noise filter AC IN 85 - 264V Inrush current limitting Detecting current Rectifier Rectifier & Smooth ADA FG Inverter Option Alarm circuit PF alarm (-W) Detecting current Control Option RC (-R) N+1 Redundancy Control External source (-W) Control Current Balance (CB) Master-Slave circuit Voltage Balance (VB) Over voltage protection Inverter Option Detecting output voltage LV alarm (-W) Rectifier & Smooth DC OUT External view 18.1 13 [0.71] [0.51] (22.6) 4-M4 Mounting hole (Bottom) [0.89] [1.14] 35 ±0.5 [1.89] 20 8-M4 Mounting hole (Both sides) Symbol VB CB +V +V -V -V FG N L Function Voltage balance Current balance Output terminal(+) Output terminal(+) Output terminal(-) Output terminal(-) Frame ground AC(N) AC(L) 130.5 ±0.5 9 29±0.5 26.5 65 [1.04] [2.56] 2-M4 Mounting hole 48 [5.14] [0.35] 11 130.5 ±0.5 Terminal cover [0.43] M3.5 FG hole 2-M4 Mounting hole ¶ Pin assign [5] [4.13] 105 ±0.5 127 9 8 [9.06] [1.38] 29 [1.14] 10 8.6 [0.39] 27.5 18 [0.71] [1.08] [0.35] 9 TB1 195 [0.75] [0.35] [0.31] VB CB +V +V -V -V FG N L [4.51] 114.5 6.6 Name plate [0.26] LED [0.64] CN3(Option) (19) [0.79] 16.2 [0.34] Voltage adjust 48 [5.14] [1.89] CN3(Option) Screw type M3 M4 Pin No. 2 1 4 3 6 5 8 7 10 9 12 11 14 13 Average 21A max per pin for TB1 1 RC+ Function : Remote ON/OFF+(-R) 2 RC- : Remote ON/OFF-(-R) 3-8 NC : N.C. 9 LV+ : LV Alarm(-W) 10 LV- : LV Alarm ground(-W) 11-12 NC : N.C. 13 PF+ : PF Alarm(-W) 14 PF- : PF Alarm ground(-W) Connector Terminal Chain:SPHD-002T-P0.5 PHDR-14VS Loose:BPHD-001T-P0.5 BPHD-002T-P0.5 *1 *1 Ratchet Hand is nothing CN3 S14B-PHDSS Mating connector Mfr. J.S.T ¶ Tolerance : ±1 [±0.04] ¶ Weight : 1.5kg max ¶ PCB material / thickness : FR-4 / 1.6mm [0.06] ¶ Chassis and cover material : aluminium ¶ Dimensions in mm, [ ]= inches ¶ Mounting torque : 1.2N • m(12.8kgf • cm) max ¶ Screw tighting torque M4 : 1.6N • m(16.9kgf • cm) max , M3 : 0.8N • m(8.5kgf • cm) max ¶ I/0 terminal for option-J and -T is shown in Instruction Manual 5. ADA-3 Ordering information AC-DC Power Supplies Enclosed type ADA750F ADA 750 1 2 F 3 -24 4 Recommended EMI/EMC Filter NAC-20-472 R ADA High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *7 G :Low leakage current E :Low leakage current and EMI class A F :with Fan unit T :Vertical terminal block J :Connector type C :with Coating R :Remote ON/OFF N1:DIN rail W:Alarms and Redundant operation Specification is changed at option,refer to Instruction Manual. Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air. SPECIFICATIONS MODEL VOLTAGE[V] FREQUENCY[Hz] ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V *1 INRUSH CURRENT[A] ACIN 200V *1 LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V *2 ACIN 100V *2 CURRENT[A] ACIN 200V *2 ACIN 200V *2 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *3 RIPPLE[mVp-p] -10 - 0C *3 0 to +50C *3 RIPPLE NOISE[mVp-p] -10 - 0C *3 TEMPERATURE REGULATION[mV] 0 to +50C *4 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION ALARM OUTPUT REMOTE ON/OFF(RC) *5 INPUT-OUTPUT -RC INPUT-FG *5 OUTPUT-RC-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ADA750F-24 ADA750F-30 ADA750F-36 ADA750F-48 AC85 - 264 1f or DC 120 - 350 (AC64 or DC90 optionally available *6) 50/60 (47 - 63) or DC 86typ (Io=100%) 86typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%) 0.99typ (Io=100%) 0.98typ (Io=100%) 20typ (Io=100%) (More than 3sec.to re-start) 40typ (Io=100%) (More than 3sec.to re-start) 0.75max (60Hz, According to IEC60950 and DEN-AN) (Io=100%) 24 30 36 48 17 (Peak 42) convection 13.5 (Peak 33.5) convection 11 (Peak 28) convection 8 (Peak 21) convection 25 (Peak 42) forced air 20 (Peak 33.5) forced air 16.5 (Peak 28) forced air 12.5 (Peak 21) forced air 19 (Peak 63) convection 15 (Peak 50) convection 12.5 (Peak 42) convection 9 (Peak 31.5) convection 31.5 (Peak 63) forced air 24.5 (Peak 50) forced air 20.5 (Peak 42) forced air 15.5 (Peak 31.5) forced air 96max 120max 144max 192max 150max 180max 240max 300max 120max 160max 200max 200max 160max 230max 260max 300max 150max 190max 230max 250max 180max 250max 280max 400max 240max 300max 360max 480max 96max 120max 144max 192max 500max (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.6 - 27.0 27.0 - 33.0 33.0 - 41.0 41.0 - 52.8 23.5 - 24.5 29.0 - 31.0 35.0 - 37.0 47.0 - 49.0 Works over 101% of peak current and recovers automatically 31 - 34.5 40 - 48 51 - 60 64 - 76 LED (Green) Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5) Requirement for external source (Option : -R, refer to Instruction Manual 5) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +71C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input) Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 *8 70X127X230mm [2.76X5X9.06 inches] (WXHXD) (without terminal block) /1.9kg max Convection/Forced air *1 The value is primary surge.The current of input surge to a built-in EMI/EMC Filter (0.2ms or less) is excluded. *2 Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown in Instruction Manual 2.3. *3 This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM101). ADA-4 *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *5 Applicable when remote control (optional) is added. *6 Derating is required.Consult us for details. *7 Please contact us about safety approvals for the model with option. *8 Please contact us about class C. * A sound may occur from power supply at pulse loading. ADA750F Block diagram Fuse 250V20A Booster inductor Noise filter AC IN 85 - 264V Inrush current limitting Detecting current Rectifier Rectifier & Smooth ADA FG Inverter Option Alarm circuit PF alarm (-W) Detecting current Control Option RC (-R) N+1 Redundancy Control External source (-W) Control Current Balance (CB) Master-Slave circuit Voltage Balance (VB) Over voltage protection Inverter Option Detecting output voltage LV alarm (-W) Rectifier & Smooth DC OUT External view 18.1 13 [0.71] [0.51] (22.6) Name plate 18 29 [0.71] [1.14] 230 [0.75] [9.06] 175.5 ±0.5 Terminal cover [1.5] 20 35 ±0.5 2-M4 Mounting hole 175.5 ±0.5 8-M4 Mounting hole (Both sides) Symbol VB CB +V +V -V -V FG N L Function Voltage balance Current balance Output terminal(+) Output terminal(+) Output terminal(-) Output terminal(-) Frame ground AC(N) AC(L) 9 [2.76] 2-M4 Mounting hole ¶ Pin assign [5] 30.5 29 ±0.5 [1.14] 70 [1.2] 38 [6.91] [0.35] 11 M3.5 FG hole [0.43] 10 8.6 [0.39] 105 ±0.5 [4.13] 127 [0.35] [0.31] 9 8 (19) [1.38] TB1 [1.08] 27.5 [4.51] VB CB +V +V -V -V FG N L [0.35] 9 114.5 6.6 [0.64] [0.26] CN3(Option) 4-M4 Mounting hole (Bottom) LED [0.34] 16.2 [0.79] [0.89] Voltage adjust 38 [6.91] [1.5] CN3(Option) Screw type M3 M4 Pin No. 2 1 4 3 6 5 8 7 10 9 12 11 14 13 Average 21A max per pin for TB1 ¶ Tolerance : ±1 [±0.04] ¶ Weight : 1.9kg max ¶ PCB material / thickness : FR-4 / 1.6mm [0.06] ¶ Chassis and cover material : aluminium ¶ Dimensions in mm, [ ]= inches ¶ Mounting torque : 1.2N • m(12.8kgf • cm) max ¶ Screw tighting torque M4 : 1.6N • m(16.9kgf • cm) max , M3 : 0.8N • m(8.5kgf • cm) max ¶ I/0 terminal for option-J and -T is shown in Instruction Manual 5. 1 RC+ Function : Remote ON/OFF+(-R) 2 RC- : Remote ON/OFF-(-R) 3-8 NC : N.C. 9 LV+ : LV Alarm(-W) 10 LV- : LV Alarm ground(-W) 11-12 NC : N.C. 13 PF+ : PF Alarm(-W) 14 PF- : PF Alarm ground(-W) Connector Terminal Chain:SPHD-002T-P0.5 PHDR-14VS Loose:BPHD-001T-P0.5 BPHD-002T-P0.5 *1 *1 Ratchet Hand is nothing CN3 S14B-PHDSS Mating connector Mfr. J.S.T ADA-5 Ordering information AC-DC Power Supplies Enclosed type ADA1000F ADA 1000 1 2 F 3 -24 4 Recommended EMI/EMC Filter NAC-20-472 R ADA High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *7 G :Low leakage current E :Low leakage current and EMI class A F :with Fan unit T :Vertical terminal block J :Connector type C :with Coating R :Remote ON/OFF N1:DIN rail W:Alarms and Redundant operation Specification is changed at option,refer to Instruction Manual. Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air. SPECIFICATIONS MODEL VOLTAGE[V] FREQUENCY[Hz] ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V *1 INRUSH CURRENT[A] ACIN 200V *1 LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V *2 ACIN 100V *2 CURRENT[A] ACIN 200V *2 ACIN 200V *2 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *3 RIPPLE[mVp-p] -10 - 0C *3 0 to +50C *3 RIPPLE NOISE[mVp-p] -10 - 0C *3 TEMPERATURE REGULATION[mV] 0 to +50C *4 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION ALARM OUTPUT REMOTE ON/OFF(RC) *5 INPUT-OUTPUT -RC INPUT-FG *5 OUTPUT-RC-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ADA1000F-24 ADA1000F-30 ADA1000F-36 ADA1000F-48 AC85 - 264 1f or DC 120 - 350 (AC64 or DC90 optionally available *6) 50/60 (47 - 63) or DC 86typ (Io=100%) 86typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%) 0.99typ (Io=100%) 0.98typ (Io=100%) 20typ (Io=100%) (More than 3sec.to re-start) 40typ (Io=100%) (More than 3sec.to re-start) 0.75max (60Hz, According to IEC60950 and DEN-AN) (Io=100%) 24 30 36 48 21 (Peak 63) convection 16.5 (Peak 50) convection 14 (Peak 42) convection 10.5 (Peak 31.5) convection 33 (Peak 63) forced air 26 (Peak 50) forced air 22 (Peak 42) forced air 16.5 (Peak 31.5) forced air 25 (Peak 83) convection 20 (Peak 66) convection 16.5 (Peak 55) convection 11.5 (Peak 41.5) convection 42 (Peak 83) forced air 33.5 (Peak 66) forced air 28 (Peak 55) forced air 21 (Peak 41.5) forced air 96max 120max 144max 192max 150max 180max 240max 300max 120max 160max 200max 200max 160max 230max 260max 300max 150max 190max 230max 250max 180max 250max 280max 400max 240max 300max 360max 480max 96max 120max 144max 192max 500max (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.6 - 27.0 27.0 - 33.0 33.0 - 41.0 41.0 - 52.8 23.5 - 24.5 29.0 - 31.0 35.0 - 37.0 47 - 49 Works over 101% of peak current and recovers automatically 31 - 34.5 40 - 48 51 - 60 64 - 76 LED (Green) Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5) Requirement for external source (Option : -R, refer to Instruction Manual 5) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +71C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input) Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 *8 75X127X280mm [2.95X5X11.02 inches] (WXHXD) (without terminal block) /2.5kg max Convection/Forced air *1 The value is primary surge.The current of input surge to a built-in EMI/EMC Filter (0.2ms or less) is excluded. *2 Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown in Instruction Manual 2.3. *3 This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM101). ADA-6 *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *5 Applicable when remote control (optional) is added. *6 Derating is required.Consult us for details. *7 Please contact us about safety approvals for the model with option. *8 Please contact us about class C. * A sound may occur from power supply at pulse loading. ADA1000F Block diagram Fuse 250V25A Booster inductor Noise filter AC IN 85 - 264V Inrush current limitting Detecting current Rectifier Rectifier & Smooth ADA FG Inverter Option Alarm circuit PF alarm (-W) Detecting current Control Option RC (-R) N+1 Redundancy Control External source (-W) Control Current Balance (CB) Master-Slave circuit Voltage Balance (VB) Over voltage protection Inverter Option Detecting output voltage LV alarm (-W) Rectifier & Smooth DC OUT External view 19.1 13 [0.75] [0.51] (23.6) Name plate (19) 6.6 [0.26] [4.13] 248 ±0.5 17 [9.76] Terminal cover [1.14] [0.35] 30.5 [1.2] [2.95] 248 ±0.5 [1.38] 2-M4 Mounting hole 35 ±0.5 Function Voltage balance Current balance Output terminal(+) Output terminal(+) Output terminal(-) Output terminal(-) Frame ground AC(N) AC(L) 9 29 ±0.5 75 [0.67] 20 ¶ Pin assign [0.43] 11 [0.34] M3.5 FG hole 2-M4 Mounting hole 8-M4 Mounting hole (Both sides) Symbol VB CB +V +V -V -V FG N L [5] 105 ±0.5 127 [0.35] [0.31] 9 8 29 [1.14] 10 8.6 [0.39] 27.5 18 [0.71] [1.08] [4.51] Short piece Don't take off the short piece. [0.35] 114.5 9 280 [11.02] [0.75] [0.79] LED VB CB +V +V -V -V FG N L TB1 4-M4 Mounting hole (Bottom) Voltage adjust [0.93] CN3 17.2 (Option) [0.68] 17 [9.76] [0.67] CN3(Option) Screw type M3 M4 Pin No. 2 1 4 3 6 5 8 7 10 9 12 11 14 13 Average 21A max per pin for TB1 1 RC+ Function : Remote ON/OFF+(-R) 2 RC- : Remote ON/OFF-(-R) 3-8 NC : N.C. 9 LV+ : LV Alarm(-W) 10 LV- : LV Alarm ground(-W) 11-12 NC : N.C. 13 PF+ : PF Alarm(-W) 14 PF- : PF Alarm ground(-W) Connector Terminal Chain:SPHD-002T-P0.5 PHDR-14VS Loose:BPHD-001T-P0.5 BPHD-002T-P0.5 *1 *1 Ratchet Hand is nothing CN3 S14B-PHDSS Mating connector Mfr. J.S.T ¶ Tolerance : ±1 [±0.04] ¶ Weight : 2.5kg max ¶ PCB material / thickness : FR-4 / 1.6mm [0.06] ¶ Chassis and cover material : aluminium ¶ Dimensions in mm, [ ]= inches ¶ Mounting torque : 1.2N • m(12.8kgf • cm) max ¶ Screw tighting torque M4 : 1.6N • m(16.9kgf • cm) max , M3 : 0.8N • m(8.5kgf • cm) max ¶ I/0 terminal for option-J and -T is shown in Instruction Manual 5. ADA-7