"VUIPSJ[FE%JTUSJCVUPS5PUBM1PXFS*OUFSOBUJPOBM*OD5PMM'SFF 64 1) XXXUPUBMQPXFSDPN Ordering information AC-DC Power Supplies Enclosed type PLA150F PLA PL 1 A 150 2 3 F 4 Recommended EMI/EMC Filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. -O 5 -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *7 C : with Coating R : Remote on/off (Required external power source) J : Connector interface T : Vertical terminal block L : Lower power consumption (0.5W max at AC240Vin, no load, ErP-compliant) N1: with DIN rail Refer to instruction manual 5.1 about optional. SPECIFICATIONS * Please consider "PBA150F-5-N" about 5V output with case cover. MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS PLA-10 ACIN 100V ACIN 115V ACIN 230V ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION Io=30 to 100% *4 Io=0 to 30% [mV] 0 to +40C RIPPLE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% 0 to +40C RIPPLE NOISE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% 0 to +40C TEMPERATURE REGULATION[mV] -10 to +40C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF *9 INPUT-OUTPUT C INPUT-FG *9 OUTPUT RC-FG *9 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR *8 EFFICIENCY[%] PLA150F-12 PLA150F-15 PLA150F-24 PLA150F-36 PLA150F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to instruction manual 1.1 and 3.2) *3 (DC input *3) 1.7typ (Io=90%) 1.6typ (Io=100%) 0.8typ (Io=100%) 50 / 60 (47 - 63) (DC input and 440Hz *3) 84typ (Io=90%) 84typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 84typ (Io=100%) 84typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) * Power factor correction is stopped at AC250V or more. 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 12.5 10 6.4 4.2 3.2 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 150.0 150.0 153.6 151.2 153.6 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max Burst operation (Please contact us about detail) 120max 120max 120max 150max 150max 160max 160max 160max 200max 400max 500max 500max 500max 500max 500max 150max 150max 150max 200max 200max 180max 180max 180max 240max 500max 600max 600max 600max 600max 600max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 500typ (ACIN 115V, Io=100%) Ta=25C 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A "VUIPSJ[FE%JTUSJCVUPS5PUBM1PXFS*OUFSOBUJPOBM*OD5PMM'SFF 64 1) XXXUPUBMQPXFSDPN PLA150F PLA SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY 41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max Convection 5-year (Depends on the used condition) OTHERS *6 *1 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). Please refer to the instruction manual 1.6. Ripple and ripple noise spec is change at Io=0 - 30% by low power mode. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *9 RC terminal is applied at option -R. And RC terminal is isolated from input, output and FG. * To meet the specifications, do not operate over-loaded condition. * Parallel operation is not possible. * A sound may occur from power supply at peak loading. *3 Derating is required. As for DC input, please contact us. *4 Please contact us about dynamic load and input response. Also, please measure output voltage in average mode because of burst operation at 30% load or less. *5 Derating is required. Please refer to instruction manual 3.2. *6 As for detail condition, please refer to instruction manual 3.3. *7 Please contact us about safety approvals for the model with option. *8 Please contact us about other class. Features - Compact design (Depth: 129mm 5.08inches) - High efficiency (90%typ PLA150F-24, AC230Vin, 100% load) - Low power consumption (1.5W typ AC240Vin, no load at standard model) - Lower power consumption (0.5Wmax AC240Vin, no load at option -L: refer to instruction manual) - UL508 approved (Except option -J), and complies with SEMI F47 (Refer to instruction manual 1.1) - Various option (Optional connectors : Vertical terminal block, Connector wiring) Block diagram FUSE 250V 4A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG RC(-R) CURRENT SENSING BOOSTER INDUCTOR CURRENT SENSING EXTERNAL SOURCE CONTROL RECTIFIER AND FILTER OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER INVERTER CONTROL DC OUT External view External size of option R, J, N1 and T is different from standard model, and refer to "5 Option and others" of instruction manual for detail. Name plate 2-M3 Mounting hole (Bottom side) Point B M3.5 AC(L) Terminal cover AC(N) Point A [0.86] [0.57] 14±1.5 [0.55] 14.6±1.5 22±1.5 [3.82] 97 49.5 [1.95] 9.5 [0.37] LED 32.8±1.5 [1.29] Output voltage adjustable potentiometer B [0.24] Output terminal(+) 6.2 8.2 Output terminal(-) [0.32] FG( ) 2 1 CN4 Connector for Remote ON/OFF (option) 11.92±1.5(LED) 19 96±0.5 [3.78] [0.75] 12.5max 129 [0.49] [5.08] [0.47] 121 [4.76] 48 [1.89] 70±0.5 [2.76] 41 [1.61] [0.47] [0.71] 12 18±0.5 [0.83] 3.5 [0.83] 28.5 [1.12] 21 3.5 4 [0.16] [0.14] [0.46] ¶ Tolerance : ±1 [±0.04] ¶ Weight : 600g max ¶ PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] ¶ Chassis material : Aluminum ¶ Cover material : Electric galvanizing steel board ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque : 0.49N-m max ¶ Screw tightening torque : M3.5 1.0N-m max ¶ Please connect safety ground to FG terminal on the unit. 21 [0.14] 11.6±1.5(potentiometer) 3-M3 Mounting hole PLA-11