Ordering information AC-DC Power Supplies Open Frame/ Enclosed type LFP100F PRELIMINARY LF 1 P 2 100 F 3 4 Recommended EMI/EMC Filter NAC-04-472 LFP High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. -O 5 -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G : Low leakage current J1: VH(J.S.T.)connector type R : with Remote ON/OFF R2: with Remote ON/OFF S : with Chassis SN: with Chassis & cover Please refer to Instruction manual 5. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LFP100F-24-Y 103.2 (201.6) Convection 24V 4.3A (8.4A) *2 *2 LFP100F-36-Y 100.8 (201.6) 36V 2.8A (5.6A) LFP100F-48-Y 100.8 (201.6) 48V 2.1A (4.2A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V*2 CURRENT[A] ACIN 200V*2 LINE REGULATION[mV] *7 LOAD REGULATION[mV] *7 0 to +50C*3 RIPPLE[mVp-p] -10 - 0C *3 0 to +50C*3 RIPPLE NOISE[mVp-p] -10 - 0C *3 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *4 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF *6 INPUT-OUTPUT.RC INPUT-FG *6 OUTPUT.RC-FG *6 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS (AT ONIY AC input) CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] LFP100F-24-Y LFP100F-36-Y LFP100F-48-Y AC85 - 264 1f (Refer to Instruction Manual 1.1) *5 1.3typ(Io=100%) 0.7typ(Io=100%) 50 / 60 (47 - 63) 84.0typ (Io=100%) 84.0typ (Io=100%) 84.5typ (Io=100%) 87.0typ (Io=100%) 87.0typ (Io=100%) 87.0typ (Io=100%) 0.99typ (Io=100%) 0.95typ (Io=100%) 15typ (Io=100%) (At cold start) (Ta=25C) 30typ (Io=100%) (At cold start) (Ta=25C) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 24 36 48 4.3 (Peak 7.0) 2.8 (Peak 4.7) 2.1 (Peak 3.5) 4.3 (Peak 8.4) 2.8 (Peak 5.4) 2.1 (Peak 4.2) 96max 144max 192max 150max 240max 240max 120max 150max 150max 160max 200max 200max 150max 250max 250max 180max 300max 480max 240max 360max 480max 290max 450max 600max 96max 144max 192max 350typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.60 to 27.50 32.40 to 39.60 39.60 to 52.80 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 101% of rating and recovers automatically 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (Class A) *8 62X33.5X155mm [2.44X1.32X6.10 inches] (WXHXD) / 300g max (without chassis and cover) Convection (Refer to Instruction Manual 3.1 and 3.2) *5 *1 Specification is changeed at option, refer to Instruction Manual. *2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. *3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. LFP-2 *5 *6 *7 *8 * * * Derating is required. Applicable when remote control (optional) is added. Please contact us about dynamic load and input response. Please contact us about another class. To meet the specifications. Do not operate over-loaded condition. Derating is required when operated with chassis and cover. Sound noise may be generated by power supply in case of pulse load. LFP100F Block diagram FUSE 250V3.15A NOISE FILTER AC IN 85 - 264V RECTIFIER INRUSH CURRENT LIMIT LFP FG Photocoupler OPTION CURRENT SENSING BOOSTER INDUCTER RC EXTERNAL SOURCE Photocoupler CURRENT SENSING RECTIFIER AND FILTER CONTROL E CONTROL Photocoupler OVER VOLTAGE PROTECTION INVERTER INVERTER RECTIFIER AND FILTER TRANSFORMER CONTROL DC OUT External view ¶ External size of option is different from standard model. Standard type Input(N) 1 Input(L) 1 2 1 CN4 CN2 Output(-) 4 5 CN1 Output(+) 13 [0.51] 23 [0.91] FG Input(N) 1 2 1 5 3 Input(L) CN1 Output(+) 8 Mounting Hole 30 [1.18] 3.5max [0.14] 185 [7.28] 173±0.5 [6.81] f4.5 6 [0.24] 4.5 [0.18] 20 15 [0.79] [0.59] 45 [1.77] Voltage adjust 145±0.5 [5.71] 155 [6.1] 5 [0.2] 4 [0.16] 16.5 [0.65] 3.5 [0.14] 5 [0.2] Point B CN2 Output(-) 4 5 1 8 Point A 2-M4 Mounting Hole ¶1 4-M4 Mounting Hole 72 [2.83] FG 3 6 [0.24] 173±0.5 [6.81] 2-f4.5 4.5 [0.18] 36 [1.42] 62 [2.44] 52±0.5 [2.05] 5 Connector for Remote ON/OFF (Optional) 3-f3.5 Mounting Hole 45±0.5 [1.77] 25±0.5 [0.98] Name plate FG Chassis and cover type PCB t=1.6 ¶1 Surface mount device ¶ 4 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 CN2 1-1123723-8 1-1123722-8 Terminal 1123721-1 Chain Loose 1318912-1 Chain 1123721-1 Loose 1318912-1 (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:VH(J.S.T) connector type. Connector type <PIN CONNECTION> CN1 Pin No. 1 2 3 4 5 CN4 Option (Mfr:J.S.T) CN2 Input AC(L) AC(N) Pin No. Output 1 to 4 -V 5 to 8 +V FG ¶ Keep drawing current per pin below 5A for CN2. ¶ Tolerance : ±1 [±0.04] ¶ Weight : 300g max (without chassis and cover) ¶ PCB material : CEM3 ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max PIN No. 1 2 Contents RC(+) RC(-) Barrier strip type Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 LFP-3 Ordering information AC-DC Power Supplies Open Frame/ Enclosed type LFP150F PRELIMINARY LF 1 P 2 150 F 3 4 Recommended EMI/EMC Filter NAC-04-472 LFP High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. -O 5 -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G : Low leakage current J1: VH(J.S.T.)connector type R : with Remote ON/OFF R2: with Remote ON/OFF S : with Chassis SN: with Chassis & cover Please refer to Instruction manual 5. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LFP150F-24-Y 151.2 (302.4) Convection 24V 6.3A (12.6A) *2 *2 LFP150F-36-Y 151.2 (302.4) 36V 4.2A (8.4A) LFP150F-48-Y 153.6 (302.4) 48V 3.2A (6.3A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V*2 CURRENT[A] ACIN 200V*2 LINE REGULATION[mV] *7 LOAD REGULATION[mV] *7 0 to +50C*3 RIPPLE[mVp-p] -10 - 0C *3 0 to +50C*3 RIPPLE NOISE[mVp-p] -10 - 0C *3 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *4 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF *6 INPUT-OUTPUT.RC INPUT-FG *6 OUTPUT.RC-FG *6 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS (AT ONIY AC input) CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] LFP150F-24-Y LFP150F-36-Y LFP150F-48-Y AC85 - 264 1f (Refer to Instruction Manual 1.1) *5 2.0typ(Io=100%) 1.0typ(Io=100%) 50 / 60 (47 - 63) 85.0typ (Io=100%) 85.0typ (Io=100%) 85.0typ (Io=100%) 87.5typ (Io=100%) 87.5typ (Io=100%) 88.0typ (Io=100%) 0.99typ (Io=100%) 0.95typ (Io=100%) 15typ (Io=100%) (At cold start) (Ta=25C) 30typ (Io=100%) (At cold start) (Ta=25C) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 24 36 48 6.3 (Peak 10.0) 4.2 (Peak 6.7) 3.2 (Peak 5.0) 6.3 (Peak 12.6) 4.2 (Peak 8.4) 3.2 (Peak 6.3) 96max 144max 192max 150max 240max 240max 120max 150max 150max 160max 200max 200max 150max 250max 250max 180max 300max 480max 240max 360max 480max 290max 450max 600max 96max 144max 192max 350typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.60 to 27.50 32.40 to 39.60 39.60 to 52.80 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 101% of rating and recovers automatically 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (Class A) *8 75X37.0X160mm [2.95X1.46X6.30 inches] (WXHXD) / 390g max (without chassis and cover) Convection (Refer to Instruction Manual 3.1 and 3.2) *5 *1 Specification is changeed at option, refer to Instruction Manual. *2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. *3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. LFP-4 *5 *6 *7 *8 * * * Derating is required. Applicable when remote control (optional) is added. Please contact us about dynamic load and input response. Please contact us about another class. To meet the specifications. Do not operate over-loaded condition. Derating is required when operated with chassis and cover. Sound noise may be generated by power supply in case of pulse load. LFP150F Block diagram FUSE 250V5A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER LFP FG Photocoupler OPTION CURRENT SENSING BOOSTER INDUCTER RC EXTERNAL SOURCE Photocoupler CURRENT SENSING RECTIFIER AND FILTER CONTROL E CONTROL Photocoupler INVERTER OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER TRANSFORMER CONTROL DC OUT External view ¶ External size of option is different from standard model. Standard type 2-f4.5 FG 3 Input(N) FG Input(N) Input(L) CN3 Output(-) Input(L) CN1 1 7 1 CN2 Output(+) 1 5 CN3 Output(-) 3 1 7 1 CN1 CN2 Output(+) 6 6 Mounting Hole 188 [7.4] 176±0.5 [6.93] f4.5 6 [0.24] 4.5 [0.18] 20 15 [0.79] [0.59] 47 [1.85] 4 [0.16] 18 [0.71] 33.5 [1.32] 5 [0.2] Connector for RemoteON/OFF (optional) Voltage adjust 150±0.5 [5.91] 160 [6.3] 2 1 2 1 3.5 [0.14] 6.5 [0.26] 5 [0.2] CN4 2-M4 Mounting Hole 3.5max [0.14] 4-M4 Mounting Hol 42 [1.65] 1 5 6 [0.24] 176±0.5 [6.93] 85 [3 35] 3-f3.5 Mounting Hole 4.5 [0.18] Point B Point A 15 [0.59] 25 [0.98] Name plate 55±0.5 [2.17] 35±0.5 [1.38] 75 [2.95] 65±0.5 [2.6] FG Chassis and cover type PCB t=1.6 ¶1 ¶1 Surface mount device ¶ 4 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 CN2 1-1123723-6 1-1123722-6 CN3 1-1123723-7 1-1123722-7 Terminal Chain 1123721-1 1318912-1 Loose Chain 1123721-1 1318912-1 Loose Chain 1123721-1 1318912-1 Loose (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:VH(J.S.T) connector type. Connector type <PIN CONNECTION> CN1 Pin No. 1 2 3 4 5 CN2 CN3 CN4 Option (Mfr:J.S.T) Input AC(L) Pin No. Output Pin No. Output AC(N) 1 to 6 +V 1 to 7 -V PIN No. 1 2 Contents RC(+) RC(-) Barrier strip type FG ¶ Keep drawing current per pin below 5A for CN2,CN3. ¶ Tolerance : ±1 [±0.04] ¶ Weight : 390g max (without chassis and cover) ¶ PCB material : CEM3 ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 LFP-5 Ordering information AC-DC Power Supplies Open Frame/ Enclosed type LFP240F PRELIMINARY LF 1 P 2 240 3 F 4 Recommended Noize Filter NAC-06-472 LFP High voltage pulse noise type : NAP series Low leakage current type : NAM series This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL MAX OUTPUT WATTAGE[W] *2 DC OUTPUT LFP240F-24-Y 300 (480) Convection 24V 10A (20A) Forced air 24V 12.5A (20A) *2 LFP240F-30-Y 300 (480) 30V 8A (16A) 30V 10A (16A) LFP240F-36-Y 302.4 (482.4) 36V 6.7A (13.4A) 36V 8.4A (13.4A) -O 5 -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G : Low leakage current J1: VH(J.S.T.)connector type R : with Remote ON/OFF R2: with Remote ON/OFF S : with Chassis SN: with Chassis & cover T : Vertical terminal block Please refer to Instruction manual 5. LFP240F-48-Y 302.4 (480) 48V 5A (10A) 48V 6.3A (10A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] EFFICIENCY[%] ACIN 100V*2 CURRENT[A] ACIN 200V*2 OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS LINE REGULATION[mV] *7 LOAD REGULATION[mV] *7 0 to +45C*3 RIPPLE[mVp-p] -10 - 0C *3 0 to +45C*3 RIPPLE NOISE[mVp-p] -10 - 0C *3 0 to +45C TEMPERATURE REGULATION[mV] -10 to +45C *4 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF *6 INPUT-OUTPUT.RC INPUT-FG *6 OUTPUT.RC-FG *6 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS (AT ONIY AC input) CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD LFP240F-24-Y LFP240F-30-Y LFP240F-36-Y LFP240F-48-Y AC85 - 264 1f (Refer to Instruction Manual 1.1) *5 3.3typ(Io=100%) 1.7typ(Io=100%) 50 / 60 (47 - 63) 85.0typ (Io=100%) 85.0typ (Io=100%) 85.0typ (Io=100%) 85.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%) 0.99typ (Io=100%) 0.95typ (Io=100%) 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start) 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 24 30 36 48 10 (Peak 17.5) Convection 8 (Peak 14) Convection 6.7 (Peak 11.8) Convection 5 (Peak 8.8) Convection 12.5 (Peak 17.5) Forced air 10 (Peak 14) Forced air 8.4 (Peak 11.8) Forced air 6.3 (Peak 8.8) Forced air 10 (Peak 20) Convection 8 (Peak 16) Convection 6.7 (Peak 13.4) Convection 5 (Peak 10) Convection 12.5 (Peak 20) Forced air 10 (Peak 16) Forced air 8.4 (Peak 13.4) Forced air 6.3 (Peak 10) Forced air 96max 144max 144max 192max 150max 240max 240max 240max 120max 150max 150max 150max 160max 200max 200max 200max 150max 250max 250max 250max 180max 300max 300max 480max 240max 360max 360max 480max 290max 450max 450max 600max 96max 144max 144max 192max 350typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92 Works over 101% of rating and recovers automatically 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20 Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (Class A) *8 84X46.5X180mm [3.31X1.83X7.09 inches] (WXHXD) / 550g max (without chassis and cover) Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2) *5 *1 Specification is changeed at option, refer to Instruction Manual. *2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. *3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. LFP-6 *5 *6 *7 *8 * * * Derating is required. Applicable when remote control (optional) is added. Please contact us about dynamic load and input response. Please contact us about another class. To meet the specifications. Do not operate over-loaded condition. Derating is required when operated with chassis and cover. Sound noise may be generated by power supply in case of pulse load. LFP240F Block diagram FUSE 250V10A NOISE FILTER AC IN 85 - 264V RECTIFIER INRUSH CURRENT LIMIT LFP FG Photocoupler OPTION CURRENT SENSING RC CURRENT SENSING RECTIFIER AND FILTER E EXTERNAL SOURCE Photocoupler BOOSTER INDUCTER CONTROL CONTROL Photocoupler INVERTER OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER TRANSFORMER CONTROL DC OUT External view ¶ External size of option is different from standard model. Standard type Chassis and cover type 7 1 Mounting Hole [8.35] [7.87] ¶1 59 [1.69] 2-M4 Mounting Hole [2.32] [0.24] 4.5 [7.09] [0.14] 6 200±0.5 15 f4.5 180 43 49 212 [6.69] [0.2] [0.59] 4 Point B [0.16] [1.18] Point A [0.18] 170±0.5 CN2 Output(+) 6 3.5 89±0.5 [3.5] 4.5 CN1 CN2 Output(+) [0.14] 5 [0.2] 5 CN3 Output(-) 1 [3.86] 3 98 1 5 [0.18] [1.77] 7 1 45±0.5 CN1 65±0.5 CN3 Output(-) FG Input(N) Input(L) [1.93] [1.04] 16.5 [0.65] 1 2 1 [2.56] 74±0.5 [2.91] [3.31] 1 CN4 4-M4 Mounting Hole [0.24] 6 3.5max 84 3 FG Input(N) Input(L) 6 [7.87] 30 1 2 5 200±0.5 2-f4.5 4-f3.5 Mounting Hole 26.5 16.5 [0.65] 21 Name plate [0.83] Connector for Remote ON/OFF (Optional) Voltage adjust FG PCB t=1.6 ¶1 Surface mount device ¶ 5 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 CN2 1-1123723-6 1-1123722-6 CN3 1-1123723-7 1-1123722-7 Terminal Chain 1123721-1 1318912-1 Loose Chain 1123721-1 1318912-1 Loose Chain 1123721-1 1318912-1 Loose (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:VH(J.S.T) connector type. Connector type <PIN CONNECTION> CN1 Pin No. 1 2 3 4 5 CN2 CN3 CN4 Option (Mfr:J.S.T) Input AC(L) Pin No. Output Pin No. Output AC(N) 1 to 6 +V 1 to 7 -V PIN No. 1 2 Contents RC(+) RC(-) Barrier strip type FG ¶ Keep drawing current per pin below 5A for CN2,CN3. ¶ Tolerance : ±1 [±0.04] ¶ Weight : 550g max (without chassis and cover) ¶ PCB material : CEM3 ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 LFP-7 Ordering information AC-DC Power Supplies Open Frame/ Enclosed type LFP300F LF 1 P 2 300 3 F 4 Recommended Noize Filter NAC-06-472 LFP High voltage pulse noise type : NAP series Low leakage current type : NAM series This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL MAX OUTPUT WATTAGE[W] *2 DC OUTPUT LFP300F-24-TY 360 (600) Convection 24V 12.5A (25A) Forced air 24V 15A (25A) *2 LFP300F-30-TY 360 (600) 30V 10A (20A) 30V 12A (20A) LFP300F-36-TY 360 (604.8) 36V 8.4A (16.8A) 36V 10A (16.8A) -O 5 -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G : Low leakage current J : EP (Tyco Electronics) connector type J1 : VH (J.S.T.) connector type R : with Remote ON/OFF R2: with Remote ON/OFF S : with Chassis SN: with Chassis & cover SNF: with Chassis & cover & fan (Only 24V) T1: Holizontal terminal block Please refer to Instruction manual 5. LFP300F-48-TY 360 (604.8) 48V 6.3A (12.5A) 48V 7.5A (12.5A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] EFFICIENCY[%] ACIN 100V*2 CURRENT[A] ACIN 200V*2 OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS LINE REGULATION[mV] *7 LOAD REGULATION[mV] *7 0 to +40C*3 RIPPLE[mVp-p] -10 - 0C *3 0 to +40C*3 RIPPLE NOISE[mVp-p] -10 - 0C *3 0 to +40C TEMPERATURE REGULATION[mV] -10 to +40C *4 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF *6 INPUT-OUTPUT.RC INPUT-FG *6 OUTPUT.RC-FG *6 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS (AT ONIY AC input) CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD LFP300F-24-TY LFP300F-30-TY LFP300F-36-TY LFP300F-48-TY AC85 - 264 1f (Refer to Instruction Manual 1.1) *5 4.3typ(Io=100%) 2.2typ(Io=100%) 50 / 60 (47 - 63) 85.0typ (Io=100%) 85.5typ (Io=100%) 85.5typ (Io=100%) 85.5typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%) 0.99typ (Io=100%) 0.95typ (Io=100%) 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start) 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start) 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 24 30 36 48 12.5 (Peak 22) Convection 10 (Peak 18) Convection 8.4 (Peak 14.6) Convection 6.3 (Peak 11) Convection 15 (Peak 22) Forced air 12 (Peak 18) Forced air 10 (Peak 14.6) Forced air 7.5 (Peak 11) Forced air 12.5 (Peak 25) Convection 10 (Peak 20) Convection 8.4 (Peak 16.8) Convection 6.3 (Peak 12) Convection 15 (Peak 25) Forced air 12 (Peak 20) Forced air 10 (Peak 16.8) Forced air 7.5 (Peak 12) Forced air 96max 144max 144max 192max 150max 240max 240max 240max 120max 150max 150max 150max 160max 200max 200max 200max 150max 250max 250max 250max 180max 300max 300max 480max 240max 360max 360max 480max 290max 450max 450max 600max 96max 144max 144max 192max 350typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92 Works over 101% of rating and recovers automatically 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20 Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (Class A) *8 95X52.5X222mm [3.74X2.07X8.74 inches] (WXHXD) (without terminal block) / 810g max Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2) *5 *1 Specification is changeed at option, refer to Instruction Manual. *2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail. ( ) means peak current. There is a possibility that an internal device is damaged when the specification is exceeded. *3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. LFP-8 *5 *6 *7 *8 * * * Derating is required. Applicable when remote control (optional) is added. Please contact us about dynamic load and input response. Please contact us about another class. To meet the specifications. Do not operate over-loaded condition. Derating is required when operated with chassis and cover. Sound noise may be generated by power supply in case of pulse load. LFP300F Block diagram FUSE 250V10A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER LFP FG Photocoupler OPTION CURRENT SENSING RC EXTERNAL SOURCE Photocoupler BOOSTER INDUCTER CURRENT SENSING RECTIFIER AND FILTER CONTROL E CONTROL Photocoupler INVERTER OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER TRANSFORMER CONTROL DC OUT External view ¶ External size of option is different from standard model. Standard type Name plate Point C for Point B Connector Remote ON/OFF (Optional) Point D M4 1 2 CN4 TB2 [2.07] Output(+) [0.2] Point A 212±0.5 Voltage adjust 4 [0.16] 46.5 3.5 109±0.5 [4.29] [0.14] 5.5 5 [0.22] 5 M4 [0.2] 8.6 Output(-) Input(L) [0.34] [0.39] 10 52.5 85±0.5 Input(N) TB1 [3.35] 95 [3.74] FG 18.5 10 FG [0.73] [0.39] 8.6 [0.34] 4-f3.5 Mounting Hole Mounting Hole [1.83] [8.35] 222 Connector type [8.74] PIN No. 1 2 [1.93] 49 CN4 Option (Mfr:J.S.T) Contents RC(+) RC(-) [0.14] 3.5max Barrier strip type ¶1 PCB t=1.6 ¶1 Surface mount device ¶ 5 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B, Point C, Point D are thermometry points. Please refer to Instruction Manual 3. ¶ Keep drawing current per pin below 20A for TB2. Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 ¶ Tolerance : ±1 [±0.04] ¶ Weight : 810g max (without chassis and cover) ¶ PCB material : CEM3 ¶ Dimensions in mm, [ ]=inches ¶ Screw tightening torque : M4 1.6N-m (16.9kgf-cm) max LFP-9