LFP100F

Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LFP100F PRELIMINARY
LF
1
P
2
100
F
3
4
Recommended EMI/EMC Filter
NAC-04-472
LFP
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
to connect with several devices.
-O
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *1
C : with Coating
G : Low leakage current
J1: VH(J.S.T.)connector type
R : with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
Please refer to Instruction
manual 5.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFP100F-24-Y
103.2 (201.6)
Convection 24V 4.3A (8.4A)
*2
*2
LFP100F-36-Y
100.8 (201.6)
36V 2.8A (5.6A)
LFP100F-48-Y
100.8 (201.6)
48V 2.1A (4.2A)
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V*2
CURRENT[A]
ACIN 200V*2
LINE REGULATION[mV] *7
LOAD REGULATION[mV] *7
0 to +50C*3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +50C*3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*4
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
*6
INPUT-OUTPUT.RC
INPUT-FG
*6
OUTPUT.RC-FG
*6
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE *5
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (AT ONIY AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LFP100F-24-Y
LFP100F-36-Y
LFP100F-48-Y
AC85 - 264 1f (Refer to Instruction Manual 1.1) *5
1.3typ(Io=100%)
0.7typ(Io=100%)
50 / 60 (47 - 63)
84.0typ (Io=100%)
84.0typ (Io=100%)
84.5typ (Io=100%)
87.0typ (Io=100%)
87.0typ (Io=100%)
87.0typ (Io=100%)
0.99typ (Io=100%)
0.95typ (Io=100%)
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
36
48
4.3 (Peak 7.0)
2.8 (Peak 4.7)
2.1 (Peak 3.5)
4.3 (Peak 8.4)
2.8 (Peak 5.4)
2.1 (Peak 4.2)
96max
144max
192max
150max
240max
240max
120max
150max
150max
160max
200max
200max
150max
250max
250max
180max
300max
480max
240max
360max
480max
290max
450max
600max
96max
144max
192max
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.60 to 27.50
32.40 to 39.60
39.60 to 52.80
24.00 to 24.96
36.00 to 37.44
48.00 to 49.92
Works over 101% of rating and recovers automatically
27.60 to 33.60
41.40 to 50.40
55.20 to 67.20
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Class A) *8
62X33.5X155mm [2.44X1.32X6.10 inches] (WXHXD) / 300g max (without chassis and cover)
Convection (Refer to Instruction Manual 3.1 and 3.2) *5
*1 Specification is changeed at option, refer to Instruction Manual.
*2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail.
( ) means peak current. There is a possibility that an internal device is damaged when the
specification is exceeded.
*3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from
output terminal.
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with
the input voltage held constant at the rated input/output.
LFP-2
*5
*6
*7
*8
*
*
*
Derating is required.
Applicable when remote control (optional) is added.
Please contact us about dynamic load and input response.
Please contact us about another class.
To meet the specifications. Do not operate over-loaded condition.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
LFP100F
Block diagram
FUSE
250V3.15A
NOISE
FILTER
AC IN 85 - 264V
RECTIFIER
INRUSH
CURRENT
LIMIT
LFP
FG
Photocoupler
OPTION
CURRENT
SENSING
BOOSTER
INDUCTER
RC
EXTERNAL
SOURCE
Photocoupler
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
E
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
INVERTER
INVERTER
RECTIFIER
AND
FILTER
TRANSFORMER
CONTROL
DC OUT
External view
¶ External size of option is different from standard model.
Standard type
Input(N)
1
Input(L)
1
2
1
CN4
CN2
Output(-)
4
5
CN1
Output(+)
13
[0.51]
23
[0.91]
FG
Input(N)
1
2
1
5
3
Input(L)
CN1
Output(+)
8
Mounting Hole
30
[1.18]
3.5max
[0.14]
185
[7.28]
173±0.5
[6.81]
f4.5
6
[0.24]
4.5
[0.18]
20
15
[0.79] [0.59]
45
[1.77]
Voltage adjust
145±0.5
[5.71]
155
[6.1]
5
[0.2]
4
[0.16]
16.5
[0.65]
3.5
[0.14]
5
[0.2]
Point B
CN2
Output(-)
4
5
1
8
Point A
2-M4
Mounting Hole
¶1
4-M4
Mounting Hole
72
[2.83]
FG
3
6
[0.24]
173±0.5
[6.81]
2-f4.5
4.5
[0.18]
36
[1.42]
62
[2.44]
52±0.5
[2.05]
5
Connector for
Remote ON/OFF
(Optional)
3-f3.5
Mounting Hole
45±0.5
[1.77]
25±0.5
[0.98]
Name plate
FG
Chassis and cover type
PCB t=1.6
¶1 Surface mount device
¶ 4 Mounting holes are existing.
¶ The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
¶ Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
¶ Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
I/O Connector
Mating connector
CN1 1-1123724-3
1-1123722-5
CN2 1-1123723-8
1-1123722-8
Terminal
1123721-1
Chain
Loose
1318912-1
Chain
1123721-1
Loose
1318912-1
(Mfr:Tyco Electronics)
¶ I/O Connector is Mfr. Tyco Electronics
¶ Option:-J1:VH(J.S.T) connector type.
Connector type
<PIN CONNECTION>
CN1
Pin No.
1
2
3
4
5
CN4 Option (Mfr:J.S.T)
CN2
Input
AC(L)
AC(N)
Pin No.
Output
1 to 4
-V
5 to 8
+V
FG
¶ Keep drawing current per pin below 5A for CN2.
¶ Tolerance : ±1 [±0.04]
¶ Weight : 300g max (without chassis and cover)
¶ PCB material : CEM3
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max
PIN No.
1
2
Contents
RC(+)
RC(-)
Barrier strip type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
LFP-3
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LFP150F PRELIMINARY
LF
1
P
2
150
F
3
4
Recommended EMI/EMC Filter
NAC-04-472
LFP
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
to connect with several devices.
-O
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *1
C : with Coating
G : Low leakage current
J1: VH(J.S.T.)connector type
R : with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
Please refer to Instruction
manual 5.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFP150F-24-Y
151.2 (302.4)
Convection 24V 6.3A (12.6A)
*2
*2
LFP150F-36-Y
151.2 (302.4)
36V 4.2A (8.4A)
LFP150F-48-Y
153.6 (302.4)
48V 3.2A (6.3A)
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V*2
CURRENT[A]
ACIN 200V*2
LINE REGULATION[mV] *7
LOAD REGULATION[mV] *7
0 to +50C*3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +50C*3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*4
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
*6
INPUT-OUTPUT.RC
INPUT-FG
*6
OUTPUT.RC-FG
*6
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE *5
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (AT ONIY AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LFP150F-24-Y
LFP150F-36-Y
LFP150F-48-Y
AC85 - 264 1f (Refer to Instruction Manual 1.1) *5
2.0typ(Io=100%)
1.0typ(Io=100%)
50 / 60 (47 - 63)
85.0typ (Io=100%)
85.0typ (Io=100%)
85.0typ (Io=100%)
87.5typ (Io=100%)
87.5typ (Io=100%)
88.0typ (Io=100%)
0.99typ (Io=100%)
0.95typ (Io=100%)
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
36
48
6.3 (Peak 10.0)
4.2 (Peak 6.7)
3.2 (Peak 5.0)
6.3 (Peak 12.6)
4.2 (Peak 8.4)
3.2 (Peak 6.3)
96max
144max
192max
150max
240max
240max
120max
150max
150max
160max
200max
200max
150max
250max
250max
180max
300max
480max
240max
360max
480max
290max
450max
600max
96max
144max
192max
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.60 to 27.50
32.40 to 39.60
39.60 to 52.80
24.00 to 24.96
36.00 to 37.44
48.00 to 49.92
Works over 101% of rating and recovers automatically
27.60 to 33.60
41.40 to 50.40
55.20 to 67.20
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Class A) *8
75X37.0X160mm [2.95X1.46X6.30 inches] (WXHXD) / 390g max (without chassis and cover)
Convection (Refer to Instruction Manual 3.1 and 3.2) *5
*1 Specification is changeed at option, refer to Instruction Manual.
*2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail.
( ) means peak current. There is a possibility that an internal device is damaged when the
specification is exceeded.
*3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from
output terminal.
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with
the input voltage held constant at the rated input/output.
LFP-4
*5
*6
*7
*8
*
*
*
Derating is required.
Applicable when remote control (optional) is added.
Please contact us about dynamic load and input response.
Please contact us about another class.
To meet the specifications. Do not operate over-loaded condition.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
LFP150F
Block diagram
FUSE
250V5A
NOISE
FILTER
AC IN 85 - 264V
INRUSH
CURRENT
LIMIT
RECTIFIER
LFP
FG
Photocoupler
OPTION
CURRENT
SENSING
BOOSTER
INDUCTER
RC
EXTERNAL
SOURCE
Photocoupler
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
E
CONTROL
Photocoupler
INVERTER
OVER VOLTAGE
PROTECTION
INVERTER
RECTIFIER
AND
FILTER
TRANSFORMER
CONTROL
DC OUT
External view
¶ External size of option is different from standard model.
Standard type
2-f4.5
FG
3
Input(N)
FG
Input(N)
Input(L)
CN3
Output(-)
Input(L)
CN1
1
7
1
CN2
Output(+)
1
5
CN3
Output(-)
3
1
7
1
CN1
CN2
Output(+)
6
6
Mounting Hole
188
[7.4]
176±0.5
[6.93]
f4.5
6
[0.24]
4.5
[0.18]
20
15
[0.79] [0.59]
47
[1.85]
4
[0.16]
18
[0.71]
33.5
[1.32]
5
[0.2]
Connector for RemoteON/OFF (optional)
Voltage adjust
150±0.5
[5.91]
160
[6.3]
2 1
2 1
3.5
[0.14]
6.5
[0.26]
5
[0.2]
CN4
2-M4
Mounting Hole
3.5max
[0.14]
4-M4
Mounting Hol
42
[1.65]
1
5
6
[0.24]
176±0.5
[6.93]
85
[3 35]
3-f3.5
Mounting Hole
4.5
[0.18]
Point B
Point A
15
[0.59]
25
[0.98]
Name plate
55±0.5
[2.17]
35±0.5
[1.38]
75
[2.95]
65±0.5
[2.6]
FG
Chassis and cover type
PCB t=1.6
¶1
¶1 Surface mount device
¶ 4 Mounting holes are existing.
¶ The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
¶ Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
¶ Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
I/O Connector
Mating connector
CN1 1-1123724-3
1-1123722-5
CN2 1-1123723-6
1-1123722-6
CN3 1-1123723-7
1-1123722-7
Terminal
Chain
1123721-1
1318912-1
Loose
Chain
1123721-1
1318912-1
Loose
Chain
1123721-1
1318912-1
Loose
(Mfr:Tyco Electronics)
¶ I/O Connector is Mfr. Tyco Electronics
¶ Option:-J1:VH(J.S.T) connector type.
Connector type
<PIN CONNECTION>
CN1
Pin No.
1
2
3
4
5
CN2
CN3
CN4 Option (Mfr:J.S.T)
Input
AC(L)
Pin No.
Output
Pin No.
Output
AC(N)
1 to 6
+V
1 to 7
-V
PIN No.
1
2
Contents
RC(+)
RC(-)
Barrier strip type
FG
¶ Keep drawing current per pin below 5A for CN2,CN3.
¶ Tolerance : ±1 [±0.04]
¶ Weight : 390g max (without chassis and cover)
¶ PCB material : CEM3
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
LFP-5
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LFP240F PRELIMINARY
LF
1
P
2
240
3
F
4
Recommended Noize Filter
NAC-06-472
LFP
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
*2
DC OUTPUT
LFP240F-24-Y
300 (480)
Convection 24V 10A (20A)
Forced air 24V 12.5A (20A)
*2
LFP240F-30-Y
300 (480)
30V 8A (16A)
30V 10A (16A)
LFP240F-36-Y
302.4 (482.4)
36V 6.7A (13.4A)
36V 8.4A (13.4A)
-O
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *1
C : with Coating
G : Low leakage current
J1: VH(J.S.T.)connector type
R : with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
T : Vertical terminal block
Please refer to Instruction
manual 5.
LFP240F-48-Y
302.4 (480)
48V 5A (10A)
48V 6.3A (10A)
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
EFFICIENCY[%]
ACIN 100V*2
CURRENT[A]
ACIN 200V*2
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
LINE REGULATION[mV] *7
LOAD REGULATION[mV] *7
0 to +45C*3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +45C*3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +45C
TEMPERATURE REGULATION[mV]
-10 to +45C
*4
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
*6
INPUT-OUTPUT.RC
INPUT-FG
*6
OUTPUT.RC-FG
*6
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE *5
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (AT ONIY AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
LFP240F-24-Y
LFP240F-30-Y
LFP240F-36-Y
LFP240F-48-Y
AC85 - 264 1f (Refer to Instruction Manual 1.1) *5
3.3typ(Io=100%)
1.7typ(Io=100%)
50 / 60 (47 - 63)
85.0typ (Io=100%)
85.0typ (Io=100%)
85.0typ (Io=100%)
85.0typ (Io=100%)
88.0typ (Io=100%)
88.0typ (Io=100%)
88.0typ (Io=100%)
88.0typ (Io=100%)
0.99typ (Io=100%)
0.95typ (Io=100%)
15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
30
36
48
10 (Peak 17.5) Convection 8 (Peak 14) Convection
6.7 (Peak 11.8) Convection 5 (Peak 8.8) Convection
12.5 (Peak 17.5) Forced air 10 (Peak 14) Forced air
8.4 (Peak 11.8) Forced air 6.3 (Peak 8.8) Forced air
10 (Peak 20) Convection
8 (Peak 16) Convection
6.7 (Peak 13.4) Convection 5 (Peak 10) Convection
12.5 (Peak 20) Forced air
10 (Peak 16) Forced air
8.4 (Peak 13.4) Forced air 6.3 (Peak 10) Forced air
96max
144max
144max
192max
150max
240max
240max
240max
120max
150max
150max
150max
160max
200max
200max
200max
150max
250max
250max
250max
180max
300max
300max
480max
240max
360max
360max
480max
290max
450max
450max
600max
96max
144max
144max
192max
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.60 to 27.50
27.00 to 33.00
32.40 to 39.60
39.60 to 52.80
24.00 to 24.96
30.00 to 31.20
36.00 to 37.44
48.00 to 49.92
Works over 101% of rating and recovers automatically
27.60 to 33.60
34.50 to 42.00
41.40 to 50.40
55.20 to 67.20
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Class A) *8
84X46.5X180mm [3.31X1.83X7.09 inches] (WXHXD) / 550g max (without chassis and cover)
Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2) *5
*1 Specification is changeed at option, refer to Instruction Manual.
*2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail.
( ) means peak current. There is a possibility that an internal device is damaged when the
specification is exceeded.
*3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from
output terminal.
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with
the input voltage held constant at the rated input/output.
LFP-6
*5
*6
*7
*8
*
*
*
Derating is required.
Applicable when remote control (optional) is added.
Please contact us about dynamic load and input response.
Please contact us about another class.
To meet the specifications. Do not operate over-loaded condition.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
LFP240F
Block diagram
FUSE
250V10A
NOISE
FILTER
AC IN 85 - 264V
RECTIFIER
INRUSH
CURRENT
LIMIT
LFP
FG
Photocoupler
OPTION
CURRENT
SENSING
RC
CURRENT
SENSING
RECTIFIER
AND
FILTER
E
EXTERNAL
SOURCE
Photocoupler
BOOSTER
INDUCTER
CONTROL
CONTROL
Photocoupler
INVERTER
OVER VOLTAGE
PROTECTION
INVERTER
RECTIFIER
AND
FILTER
TRANSFORMER
CONTROL
DC OUT
External view
¶ External size of option is different from standard model.
Standard type
Chassis and cover type
7
1
Mounting Hole
[8.35]
[7.87]
¶1
59
[1.69]
2-M4
Mounting Hole
[2.32]
[0.24]
4.5
[7.09]
[0.14]
6
200±0.5
15
f4.5
180
43
49
212
[6.69]
[0.2]
[0.59]
4
Point B [0.16]
[1.18]
Point A
[0.18]
170±0.5
CN2
Output(+)
6
3.5
89±0.5
[3.5]
4.5
CN1
CN2
Output(+)
[0.14]
5
[0.2]
5
CN3
Output(-)
1
[3.86]
3
98
1
5
[0.18]
[1.77]
7
1
45±0.5
CN1
65±0.5
CN3
Output(-)
FG
Input(N)
Input(L)
[1.93]
[1.04]
16.5
[0.65]
1
2
1
[2.56]
74±0.5
[2.91]
[3.31]
1
CN4
4-M4
Mounting Hole
[0.24]
6
3.5max
84
3
FG
Input(N)
Input(L)
6
[7.87]
30
1
2
5
200±0.5
2-f4.5
4-f3.5
Mounting Hole
26.5
16.5
[0.65]
21
Name plate
[0.83]
Connector for Remote ON/OFF (Optional)
Voltage adjust
FG
PCB t=1.6
¶1 Surface mount device
¶ 5 Mounting holes are existing.
¶ The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
¶ Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
¶ Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
I/O Connector
Mating connector
CN1 1-1123724-3
1-1123722-5
CN2 1-1123723-6
1-1123722-6
CN3 1-1123723-7
1-1123722-7
Terminal
Chain
1123721-1
1318912-1
Loose
Chain
1123721-1
1318912-1
Loose
Chain
1123721-1
1318912-1
Loose
(Mfr:Tyco Electronics)
¶ I/O Connector is Mfr. Tyco Electronics
¶ Option:-J1:VH(J.S.T) connector type.
Connector type
<PIN CONNECTION>
CN1
Pin No.
1
2
3
4
5
CN2
CN3
CN4 Option (Mfr:J.S.T)
Input
AC(L)
Pin No.
Output
Pin No.
Output
AC(N)
1 to 6
+V
1 to 7
-V
PIN No.
1
2
Contents
RC(+)
RC(-)
Barrier strip type
FG
¶ Keep drawing current per pin below 5A for CN2,CN3.
¶ Tolerance : ±1 [±0.04]
¶ Weight : 550g max (without chassis and cover)
¶ PCB material : CEM3
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
LFP-7
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed type
LFP300F
LF
1
P
2
300
3
F
4
Recommended Noize Filter
NAC-06-472
LFP
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
*2
DC OUTPUT
LFP300F-24-TY
360 (600)
Convection 24V 12.5A (25A)
Forced air 24V 15A (25A)
*2
LFP300F-30-TY
360 (600)
30V 10A (20A)
30V 12A (20A)
LFP300F-36-TY
360 (604.8)
36V 8.4A (16.8A)
36V 10A (16.8A)
-O
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *1
C : with Coating
G : Low leakage current
J : EP (Tyco Electronics) connector type
J1 : VH (J.S.T.) connector type
R : with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
SNF: with Chassis & cover & fan
(Only 24V)
T1: Holizontal terminal block
Please refer to Instruction manual 5.
LFP300F-48-TY
360 (604.8)
48V 6.3A (12.5A)
48V 7.5A (12.5A)
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
EFFICIENCY[%]
ACIN 100V*2
CURRENT[A]
ACIN 200V*2
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
LINE REGULATION[mV] *7
LOAD REGULATION[mV] *7
0 to +40C*3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +40C*3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +40C
TEMPERATURE REGULATION[mV]
-10 to +40C
*4
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
*6
INPUT-OUTPUT.RC
INPUT-FG
*6
OUTPUT.RC-FG
*6
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE *5
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (AT ONIY AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
LFP300F-24-TY
LFP300F-30-TY
LFP300F-36-TY
LFP300F-48-TY
AC85 - 264 1f (Refer to Instruction Manual 1.1) *5
4.3typ(Io=100%)
2.2typ(Io=100%)
50 / 60 (47 - 63)
85.0typ (Io=100%)
85.5typ (Io=100%)
85.5typ (Io=100%)
85.5typ (Io=100%)
88.0typ (Io=100%)
88.0typ (Io=100%)
88.0typ (Io=100%)
88.0typ (Io=100%)
0.99typ (Io=100%)
0.95typ (Io=100%)
15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
30
36
48
12.5 (Peak 22) Convection 10 (Peak 18) Convection
8.4 (Peak 14.6) Convection 6.3 (Peak 11) Convection
15 (Peak 22) Forced air
12 (Peak 18) Forced air
10 (Peak 14.6) Forced air 7.5 (Peak 11) Forced air
12.5 (Peak 25) Convection 10 (Peak 20) Convection
8.4 (Peak 16.8) Convection 6.3 (Peak 12) Convection
15 (Peak 25) Forced air
12 (Peak 20) Forced air
10 (Peak 16.8) Forced air 7.5 (Peak 12) Forced air
96max
144max
144max
192max
150max
240max
240max
240max
120max
150max
150max
150max
160max
200max
200max
200max
150max
250max
250max
250max
180max
300max
300max
480max
240max
360max
360max
480max
290max
450max
450max
600max
96max
144max
144max
192max
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.60 to 27.50
27.00 to 33.00
32.40 to 39.60
39.60 to 52.80
24.00 to 24.96
30.00 to 31.20
36.00 to 37.44
48.00 to 49.92
Works over 101% of rating and recovers automatically
27.60 to 33.60
34.50 to 42.00
41.40 to 50.40
55.20 to 67.20
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Class A) *8
95X52.5X222mm [3.74X2.07X8.74 inches] (WXHXD) (without terminal block) / 810g max
Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2) *5
*1 Specification is changeed at option, refer to Instruction Manual.
*2 Peak loading for 10sec. AND Duty 40% max, refer to Instruction Manual 5. In detail.
( ) means peak current. There is a possibility that an internal device is damaged when the
specification is exceeded.
*3 This is the value that measured on measuring board with capacitor of 22mF at 150mm from
output terminal.
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with
the input voltage held constant at the rated input/output.
LFP-8
*5
*6
*7
*8
*
*
*
Derating is required.
Applicable when remote control (optional) is added.
Please contact us about dynamic load and input response.
Please contact us about another class.
To meet the specifications. Do not operate over-loaded condition.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
LFP300F
Block diagram
FUSE
250V10A
NOISE
FILTER
AC IN 85 - 264V
INRUSH
CURRENT
LIMIT
RECTIFIER
LFP
FG
Photocoupler
OPTION
CURRENT
SENSING
RC
EXTERNAL
SOURCE
Photocoupler
BOOSTER
INDUCTER
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
E
CONTROL
Photocoupler
INVERTER
OVER VOLTAGE
PROTECTION
INVERTER
RECTIFIER
AND
FILTER
TRANSFORMER
CONTROL
DC OUT
External view
¶ External size of option is different from standard model.
Standard type
Name plate
Point C
for
Point B Connector
Remote ON/OFF
(Optional)
Point D
M4
1
2
CN4
TB2
[2.07]
Output(+)
[0.2]
Point A
212±0.5
Voltage adjust
4
[0.16]
46.5
3.5
109±0.5
[4.29]
[0.14]
5.5
5
[0.22]
5
M4
[0.2]
8.6
Output(-)
Input(L)
[0.34]
[0.39]
10
52.5
85±0.5
Input(N)
TB1
[3.35]
95
[3.74]
FG
18.5 10
FG
[0.73] [0.39]
8.6
[0.34]
4-f3.5
Mounting Hole
Mounting Hole
[1.83]
[8.35]
222
Connector type
[8.74]
PIN No.
1
2
[1.93]
49
CN4 Option (Mfr:J.S.T)
Contents
RC(+)
RC(-)
[0.14]
3.5max
Barrier strip type
¶1
PCB t=1.6
¶1 Surface mount device
¶ 5 Mounting holes are existing.
¶ The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
¶ Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
¶ Point A, Point B, Point C, Point D are thermometry points.
Please refer to Instruction Manual 3.
¶ Keep drawing current per pin below 20A for TB2.
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
BXH-001T-P0.6
or SXH-001T-P0.6
¶ Tolerance : ±1 [±0.04]
¶ Weight : 810g max (without chassis and cover)
¶ PCB material : CEM3
¶ Dimensions in mm, [ ]=inches
¶ Screw tightening torque : M4 1.6N-m (16.9kgf-cm) max
LFP-9