NFM-10 series - Total Power International

Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
NFM-10
10W Output Switching Power Supply
series
¡½ Features :
¡EUniversal AC input / Full range
¡ Protections: Short circuit / Overload / Over voltage / Over temperature
E
¡ Ultra-miniature size, light weight
E
¡ Cooling by free air convection
E
¡ Isolation class¢º
E
¡ Medical safety approved (MOPP level)
E
¡ No load power consumption<0.5W
E
¡ 100% full load burn-in test
E
¡ Fixed switching frequency at 67KHz
E
¡ High reliability
E
¡ 3 years warranty
E
SPECIFICATION
MODEL
NFM-10-3.3
NFM-10-5
NFM-10-12
NFM-10-15
NFM-10-24
DC VOLTAGE
3.3V
5V
12V
15V
24V
RATED CURRENT
2.5A
2A
0.85A
0.67A
0.42A
CURRENT RANGE
0 ~ 2.5A
0 ~ 2A
0 ~ 0.85A
0 ~ 0.67A
0 ~ 0.42A
RATED POWER
8.25W
10W
10.2W
10.05W
10.08W
150mVp-p
150mVp-p
150mVp-p
240mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
OUTPUT
INPUT
4.5 ~ 5.5V
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 26.4V
VOLTAGE TOLERANCE Note.3 ¡Ó2.0%
3 ~ 3.63V
¡Ó2.0%
¡Ó1.0%
¡Ó1.0%
¡Ó1.0%
LINE REGULATION
¡Ó1.0%
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
LOAD REGULATION
¡Ó1.0%
¡Ó1.0%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
SETUP, RISE TIME
1800ms, 20ms/230VAC
HOLD UP TIME (Typ.)
100ms/230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 440Hz
79%
79%
VOLTAGE ADJ. RANGE
EFFICIENCY (Typ.)
66%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.25A/115VAC
LEAKAGE CURRENT
PROTECTION OVER VOLTAGE
OVER TEMPERATURE Note.5
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
(Note 4)
OTHERS
78%
74%
0.15A/230VAC
COLD START 25A/115VAC
£g
45A/230VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.95V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
Tj 140¢J typically (U1) detect on main control IC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70¢J (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85¢J, 10 ~ 95% RH
¡Ó0.03%/¢J (0 ~ 50¢J)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
ANSI/AAMI ES60601-1,TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:100M Ohms / 500VDC / 25¢J/ 70% RH
Compliance to EN55011(CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
DIMENSION
PACKING
NOTE
24ms/115VAC at full load
120 ~ 370VDC
Note.6 Touch current < 80 A/264VAC
OVERLOAD
EMC
1800ms, 20ms/115VAC at full load
723.2Khrs min. MIL-HDBK-217F (25¢J)
65*45*22mm (L*W*H)
0.045Kg; 120pcs/6.4Kg/0.97CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification
provided by the IC manufacturer.
6. Touch current was measured from primary input to DC output.
File Name:NFM-10-SPEC 2012-09-03
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
NFM-10
10W Output Switching Power Supply
Mechanical Specification
series
Unit:inch(mm)
DC OUTPUT
-V
0.789"(20.04mm)
+V
0.491"
(12.47mm)
1.77"(45mm)
AC INPUT
0.689"(17.5mm)
AC/N
T2A/250V
0.22"
(5.5mm)
2.13"(54mm)
2.56"(65mm)
0.87"(22mm)
0.196"(5mm)
AC/L
0.07"(1.8mm)
0.177"(4.5mm)
0.041"(1.05mm)
0.138"(3.5mm)
Block Diagram
fosc : 67KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PWM
CONTROL
Derating Curve
+V
-V
DETECTION
CIRCUIT
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE (¢J)
60
70
(HORIZONTAL)
60
50
40
85
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:NFM-10-SPEC 2012-09-03