PA30606A01 Rev. 00 2-2007 K600-A FPC-600 and PD-600 CONVERSION KIT INSTALLATION INSTRUCTIONS © Panduit Corp. 2007 Converts the FPC-600 (Foot Petal Control) and PD-600 (Positioning Device) for use with the CT-600-A. Kit Contents: • • • Actuator (TP25343C01) Tool Clamps (1 pair) (TP25345C01) 10mm Hex wrench (CA20674A01) FPC-600 1. Disconnect the 3mm air line connected to the Foot Petal Actuating Cylinder (1). 2. Push the 3 mm air line into the air fitting on the Actuator (2). OLD FPC-600 NEW FPC-600-A Technical Support: 888-506-5400, ext. 3255 Website: www.panduit.com E-mail: [email protected] Fax: (630) 759-7532 Page: 1 of 2 K600-A INSTALLATION INSTRUCTIONS PD-600 1. 2. 3. 4. Loosen the two M12 x 80 mm HSHC screws (3) to remove CT-600. Remove the two M12 x 80 mm HSHC screws (3). Retain for latter use. Discard the 2 tool clamps (4). Install new 65 mm (2.6 in) ID pipe clamps (5) and CT-600-A with M12 x 80 mm HSHC screws (3) removed earlier. 5. Position CT-600-A at preferred position and tighten screws. OLD PD-600 NEW PD-600-A Page: 2 of 2