Description
 Automated meter reading
The SKY66100-11 is a high-performance, transmit/receive (Tx/Rx)
front-end module (FEM). The device includes a power
amplifier (PA) capable of more than +27 dBm of transmit output
power at more than 45 percent PAE for the module (55 percent
for the standalone PA). For current-sensitive applications, the PA
can be bypassed to save battery current.
 Advanced metering infrastructure
 ISM systems
Features
All functionality can be controlled by a three-wire interface. The
FEM can be placed in a deep “sleep” mode, drawing less than
1 μA of current.
 Transmit output power: >+27 dBm
 High efficiency PA
The receive chain consists of a low-loss single-pole, triple-throw
(SP3T) switch, which provides an insertion loss of approximately
0.4 dB. Three separate VCC pins enable maximum RF isolation.
 Receive loss: <0.4 dB
 Transmit bypass mode with 0.9 dB insertion loss
 Sleep mode current: < 1 μA
The SKY66100-11 is packaged in a 16-pin, 4 x 4 mm Multi-Chip
Module (MCM), which allows for a highly manufacturable low-cost
solution.
 Integrated control logic
 Small footprint MCM (16-pin, 4 x 4 mm) package
(MSL3, 260 C per JEDEC J-STD-020)
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
Output
Matching
Network
PA_OUT
TX
CSD
CTX
BYP
A functional block diagram of the SKY66100-11 is shown in
Figure 1. The 16-pin MCM package and pinout are shown in
Figure 2. Signal pin assignments and functional pin descriptions
are provided in Table 1.
TX_IN
Logic
Control
PA
SPST
Regulator
Filter
ANT
RX
SP3T
Y0537
Figure 1. SKY66100-11 FEM Block Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
1
VCC1
VCC0
VCC2
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
16
15
14
13
PA_OUT
TX 2
12
GND
CTX 3
11
GND
RX 4
10
TX_IN
9
GND
CSD_L 1
6
7
8
GND
CBYP_L
ANT
N/C 5
S2784
Figure 2. SKY66100-11 Pinout – 16-Pin MCM
(Top View)
Table 1. SKY66100-11 Signal Descriptions
Pin
Name
Description
Pin
Name
Description
1
CSD_L
Control, shutdown/sleep, active low
9
GND
Ground
2
TX
Transmit RF input
10
TX_IN
Transmit input. Externally filtered signal.
3
CTX
Control, transmit modes
11
GND
Ground
4
RX
Receive RF output
12
GND
Ground
5
N/C
No connection
13
PA_OUT
PA output
6
GND
Ground
14
VCC2
Supply for second stage of PA
7
CBYP_L
Control, transmit bypass mode
15
VCC0
Supply for logic, regulator, bias
8
ANT
Antenna I/O
16
VCC1
Supply for first stage of PA
Technical Description
Electrical and Mechanical Specifications
The SKY66100-11 consists of a complete Tx/Rx chain with Tx/Rx
switches contained in the module. An SP3T switch selects
between receive, transmit, and transmit bypass paths. The
module has a shutdown mode to minimize power consumption.
The absolute maximum ratings of the SKY66100-11 are provided
in Table 2. The recommended operating conditions are specified
in Table 3, and electrical specifications are provided in Tables 4
through 7.
Three digital input control pins (CSD_L, CTX, and CBYP_L) are
used to select between shutdown, Tx/Rx, or transmit bypass
mode, respectively.
The state of the SKY66100-11 is determined by the logic provided
in Table 8.
The bypass mode can also be configured to power-down the PA
and remove it from the RF path using an internal single-pole,
single-throw (SPST) switch.
Typical performance characteristics are shown in Figures 3
through 11.
The transmit path contains a PA optimized for saturated
performance. The PA can be passed through an external
impedance matching network and harmonic filter before being fed
through the SP3T switch. External inductors for each of the two
PA stages provide maximum application flexibility.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Table 2. SKY66100-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
+3.8
V
Supply voltage (Pins: VCC0, VCC1, VCC2)
VCC
–0.3
Digital input voltage (Pins: CSD_L, CTX, CBYP_L)
VCTL
–0.5
Receive mode (Pin: ANT)
PIN_ANT
VCC
V
+15
dBm
Transmit mode (Pin: TX)
PIN_TX
–4
dBm
Transmit RF input power, transmit bypass mode (Pin:TX)
PIN_TXB
+20
dBm
Transmit output power
POUT
+28
dBm
Voltage Standing Wave Ratio
VSWR
10:1
–
Thermal resistance
ΘJC
14.7
C/W
Operating temperature
TC
–40
+85
C
Storage temperature
TSTG
–55
+150
C
Junction temperature
TJ
+150
C
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY66100-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Operating frequency range
f
169
Supply voltage (Pins: VCC0, VCC1, VCC2)
VCC
2.0
Receive RF input power (Pin: RX)
PIN_RX
Transmit RF input power, transmit mode (Pin:TX)
PIN_TX
–6
Transmit RF input power, transmit bypass mode (Pin: TX)
PIN_TX
+15
Transmit mode duty cycle
3.3
Maximum
Units
170
MHz
3.6
V
–15
dBm
dBm
+20
dBm
50
%
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
3
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Table 4. SKY66100-11 DC Electrical Specifications (Note 1)
(VCC = +3.3 V, TC = +25 C, with Output Matching Network as Noted, Unless Otherwise Noted)
Parameter
Symbol
Receive quiescent current
(Pins: VCC0, VCC1, VCC2)
IQ_RX
Transmit quiescent current
(Pins : VCC0, VCC1, VCC2)
IQ_TX
Transmit bypass quiescent current
(Pins: VCC0, VCC1, VCC2)
IQ_TXBYP
Transmit operating current
(Pins: VCC0, VCC1, VCC2)
IOP_TX
Shutdown current (Pins: VCC0, VCC1, VCC2)
(Note 5, Note 6, and Note 7)
Test Condition
Min
Typical
Max
Units
Rx mode (Note 2)
680
μA
Tx mode
15
mA
Tx bypass mode (Note 2)
680
μA
VCC = 3.3 V, POUT = +24 dBm
(Note 3 and Note 5)
210
mA
VCC = 3.6 V,
325
mA
TX mode:
POUT = +27 dBm (Note 4)
ISD
Shutdown/sleep mode
0.02
1.0
μA
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Does not include control pin currents. See Table 7 for more information.
Note 3: Requires EK1 output match network designed for +24 dBm. See Figure 3. Contact Skyworks Application Support for more information.
Note 4: Requires EK2 output match network designed for +27 dBm. See Figure 4. Contact Skyworks Application Support for more information.
Note 5. Not production tested.
Note 6: Shutdown mode functionally verified in production to be less than 1 mA.
Note 7: All controls must be <0.1 V to achieve the specified sleep current.
Table 5. SKY66100-11 Receive Mode Electrical Specifications (Note 1)
(VCC = +3.3 V, TC = +25 C, f = 169 to 170 MHz, Characteristic Source and Load Impedance = 50 Ω, CW Input, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Receive Mode: ANT to RX Output Path (Note 2)
Insertion loss (Note 3)
IL
1 dB input compression point (Note 4)
IP1dB
+15
dBm
3 order input intercept point (Note 4)
IIP3
+29
dBm
Input return loss (Note 4)
|S11|
8
dB
Power-on time, RX (Note 4 and Note 5)
TON_RX
rd
0.4
Final mode = RX (see Table 8)
1
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Mode configured according to logic shown in Table 8.
Note 3: Insertion loss increases to 0.9 dB when using an external antenna filter. See Figure 3.
Note 4: Not production tested.
Note 5: Elapsed time is from sleep mode to the final mode indicated in Table 8. A final mode is considered achieved when its corresponding POUT is at least 90% of its final value.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E
dB
μs
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Table 6. SKY66100-11 Transmit Mode Electrical Specifications (Note 1) (Note 2)
(VCC = +3.3 V, TC = +25 C, f = 169 to 170 MHz, Characteristic Source and Load Impedance = 50 Ω, with Output Matching Network as in
Figure 3, CW Input, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Transmit Mode: TX to PA_OUT  TX_IN to ANT Path (Note 3)
Output power
POUT
VCC = 3.6 V (Note 4)
VCC = 3.3 V (Note 5 and Note 6)
+27
+24
dBm
dBm
PA power added efficiency (Note 7)
PAE_PA
At PA_OUT pin (Note 4)
At PA_OUT pin (Note 5 and Note 6)
45
55.8
%
%
2nd harmonic (Note 6 and Note 8)
2fo
–36
dBm
3rd to 10th harmonics (Note 6 and Note 8)
3fo
4fo
5fo
6fo
7fo
8fo
9fo
10fo
–54
–54
–54
–54
–54
–54
–54
–54
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
Input return loss (Note 6 and Note 9)
|S11|
PIN = –30 dBm
8
dB
Output return loss (Note 3 and Note 6)
|S22|
PIN = –30 dBm
6
dB
Non-harmonic spurious power
(Note 6, Note 8, and Note 10)
VSWR = 5:1, all phases
Power-on time (Note 6 and Note 11)
TON_TX
Receive isolation (Note 13)
|SRXTX|
–40
Final mode = transmit (see Table 8)
dBm
2.8
μs
12
dB
0.9
dB
Transmit Bypass Mode: TX to ANT Path
Insertion loss (Note 12)
IL
1 dB input compression point (Note 6)
IP1dB
nd
VCC = 3.0 to 3.6 V
21
dBm
2 harmonic (Note 6 and Note 8)
2fo
PIN_TX = +20 dBm
–36
dBm
3rd to 5th harmonics (Note 6 and Note 8)
3fo-5fo
PIN_TX = +20 dBm
–54
dBm
Input return loss (Note 6 and Note 9)
|S11|
6
dB
Output return loss (Note 3 and Note 6)
|S22|
8
dB
Transition time (Note 6 and Note 11)
tON
Receive isolation
|SRXTX|
Final mode = transmit bypass (see
Table 8)
1
μs
PIN_TX = +20 dBm
25
dB
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Mode configured according to logic shown in Table 8.
Note 3: External output matching network and filter located between PA_OUT and TX_IN (pins 13 and 10, respectively).
Note 4: Requires EK2 output match network designed for +27 dBm. See Figure 4. Contact Skyworks Application Support for more information.
Note 5: Requires EK1 output match network designed for +24 dBm. See Figure 3. Contact Skyworks Application Support for more information.
Note 6: Not production tested.
Note 7: Calculated from Evaluation Board test results with loss of output matching network.
Note 8: Final performance dependent on external filter. The 2nd to 10th harmonics are fully characterized but are not production tested.
Note 9: External input matching network.
Note 10: Measurement performed with spectrum analyzer (RBW = 100 kHz for frequencies < 1 GHz and RBW = 1 MHz for frequencies between 1 GHz and 10 GHz).
Note 11: Elapsed time is from sleep mode to the final mode indicated in Table 8. A final mode is considered achieved when its corresponding POUT is at least 90% of its final value.
Note 12: The insertion loss increases to 2 dB in TX bypass mode with the external input match. The RX bypass is not affected.
Note 13: Includes gain of PA.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
5
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Table 7. SKY66100-11 Electrical Specifications: Control Logic Characteristics (Note 1)
(TC = +25 C, Unless Otherwise Noted)
Parameter
Symbol
Control voltage (Note 2):
High
Low
VIH
VIL
Input current (Note 3):
High
Low
IIH
IIL
Test Condition
Min
Typical
1.6
0
Max
Units
VCC
0.7
V
V
TC = 25 °C
μA
μA
36
0
Note 1: Performance is guaranteed only under the conditions listed in this table. Control logic input signals are: CSD_L, CTX, and CBYP_L.
Note 2: Not production tested.
Note 3: Each control pin has a 100 kΩ pull-down resistor.
Table 8. SKY66100-11 Mode Control Logic (Note 1)
Mode
Sleep
RF Signal Path
Pin  Pin
CSD_L
(Pin 1)
CTX
(Pin 3)
CBYP_L
(Pin 7)
(Note 2)
0
X
X
Transmit bypass
TX  ANT
1
1
0
Receive
ANT  RX
1
0
X
Transmit
TX to PA_OUT  TX_IN to ANT
1
1
1
Note 1: “1” = 1.6 to Vcc, “0” = 0 to 0.7 V, “X” = don’t care.
Note 2: All I/O are disconnected from internal components.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Typical Performance Characteristics
500
26
450
24
400
22
350
20
300
18
250
16
200
14
10
-22
38
150
Pout [dBm]
ICC [mA]
12
40
-18
-16
-14
-12
-10
-8
34
169 MHz
169.5 MHz
170 MHz
32
100
50
-20
36
30
0
-6
Input Power (dBm)
Y2004
550
28
Gain (dB)
30
ICC (mA)
POUT (dBm)
(VCC = 3.6 V, f = 169 MHz CW Signal, Unless Otherwise Noted)
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
Output Power (dBm)
Y2003
Figure 4. Gain vs. POUT
Figure 3. POUT and ICC vs PIN
33
400
300
Gain (dB)
ICC (mA)
32
200
31
Y2005
30
169
169.5
0
0
170
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
Output Power (dBm)
Frequency (MHz)
Figure 6. ICC vs POUT
Figure 5. Small Signal Gain vs Frequency
40
55
2V
2.7 V
3V
3.3 V
3.6 V
39
50
38
37
40
36
2V
2.7 V
3V
3.3 V
3.6 V
30
25
17
18
19
20
21
22
23
24
25
26
Output Power (dBm)
Figure 7. PAE vs POUT and VCC
27
28
29
34
33
32
20
16
35
30
31
Y2008
35
Gain (dB)
45
Y2007
PAE (%)
Y2006
169 MHz
169.5 MHz
170 MHz
100
30
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
Output Power (dBm)
Figure 8. Gain vs POUT and VCC
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
7
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
-40
-60
-70
169 MHz
169.5 MHz
170 MHz
-80
16
17
18
19
20
21
22
23
24
25
26
27
169 MHz
169.5 MHz
170 MHz
-50
-60
-70
-80
Y2010
3rd Harmonic (dBm)
-50
Y2009
2nd Harmonic (dBm)
-40
-90
16
28
17
18
19
20
21
22
23
24
25
Output Power (dBm)
Output Power (dBm)
Figure 10. 3rd Harmonic vs POUT
Figure 9. 2nd Harmonic vs POUT
0
-10
169 MHz
169.5 MHz
170 MHz
-20
Level (dBm)
-30
-40
-50
-60
-70
Y2011
-80
-90
-100
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
Harmonics
Figure 11. Harmonics at POUT = +27 dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E
26
27
28
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Evaluation Board Description
Package and Handling Information
The SKY66100-11 Evaluation Board is used to test the
performance of the SKY66100-11 FEM. Evaluation Board
schematic diagrams are provided in Figure 12 (EK-1 board, +24
dBm) and in Figure 13 (EK-2 board, +27 dBm). An assembly
drawing for the Evaluation Board is shown in Figure 14.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
Package Dimensions
The typical part marking for the SKY66100-11 is shown in
Figure 15. The PCB layout footprint for the SKY66100-11 is
provided in Figure 16. Figure 17 shows the package dimensions
for the 16-pin MCM, and Figure 18 provides the tape and reel
dimensions.
The SKY66100-11 is rated to Moisture Sensitivity Level 3 (MSL3)
at 260 C. It can be used for lead or lead-free soldering. For
additional information, refer to the Skyworks Application Note,
PCB Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
9
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
C22
4.7 μF
J8
VCC
BYP
FB1
C28
1 μF
CTX
C29
1 μF
CSD
2
1
4
3
6
5
8
7
10
9
12
11
14
13
VCC
C27
1 nF
C30
4.7 nF
C21
DNI
L13
10 nH
L9
10 nH
2
CTX
C26
22 pF
1
4
CSD
TX
CTX
RX
L29
3.3 nH
L14
27 nH
GND
GND
TX_IN
GND
12
C16
2.2 nF
11
C23
47 pF
10
9
N/C
GND
BYP
ANT
C25
DNI
3
15 14 13
VCC2
PA_OUT
CSD
L8
27 nH
J6
SMA
16
VCC1
VCC0
Pad
17
C24
56 pF
L21
6.8 nH
5
6
7
8
BYP
C100
2.2 nF
J7
SMA
C101
22 pF
L10
47 nH
L30
4.7 nH
C19
18 pF
Notes:
L11
0Ω
L31
DNI
Some component labels may be different from the corresponding component
symbol shown here.
Component values, however, are accurate as of the date of this data sheet.
J5
SMA
C20
DNI
Y2001
Figure 12. SKY66100-11 EK-1 Evaluation Board Schematic (+24 dBm)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
C22
4.7 μF
J8
VCC
BYP
FB1
C28
1 μF
CTX
C29
1 μF
CSD
2
1
4
3
6
5
8
7
10
9
12
11
14
13
VCC
C27
1 nF
C30
4.7 nF
C21
DNI
L13
12 nH
L21
6.8 nH
L9
12 nH
2
CTX
C26
22 pF
1
4
CSD
TX
CTX
RX
L29
3.9 nH
L14
27 nH
GND
GND
TX_IN
GND
12
C16
2.2 nF
11
C23
33 pF
10
9
N/C
GND
BYP
ANT
C25
DNI
3
15 14 13
VCC2
PA_OUT
Pad
CSD
L8
27 nH
J6
SMA
16
VCC1
VCC0
17
C24
56 pF
5
6
7
8
BYP
C100
2.2 nF
J7
SMA
C101
22 pF
L10
47 nH
L30
4.7 nH
C19
18 pF
Notes:
L11
0Ω
L31
DNI
Some component labels may be different from the corresponding component
symbol shown here.
Component values, however, are accurate as of the date of this data sheet.
J5
SMA
C20
DNI
Y2002
Figure 13. SKY66100-11 EK-2 Evaluation Board Schematic (+27 dBm)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
11
Y1996
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Figure 14. SKY66100-11 Evaluation Board Assembly Drawing
(Applies to both EK-1 and EK-2 Evaluation Boards)
PCB Recommendations
Recommendations for 4-layer PCB:
 Metal Layer 1 = RF traces + control lines.
 Metal Layer 2 = Solid ground plane. No traces routing. Use vias to ground under the FEM as recommended in Figure 5.
 Metal Layer 3 and 4 = Control lines + VCC traces (no VCC plane).
 Pour copper on each layer connected to the ground plane. Use VCC traces in a star distribution pattern.
Recommendations for 2-layer PCB:
 Metal Layer 1 = RF traces + control lines + VCC.
 Metal Layer 2 = Solid ground plane between the transceiver and the FEM up to the antenna, no traces routing in that area. Use vias to
ground under the FEM as recommended in Figure 5.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Pin 1
Indicator
Skyworks Part Number
66100-11
STR#
Lot Code
Y2000
Lot Code
Figure 15. Typical Part Marking
Stencil aperture size for center
ground pads should be 80% to
100% (by area) of the solder
mask opening of the package.
4.3
0.5
0.4
0.05
0.05
0.15
4X 0.075
4.3
0.65 0.75
4X 0.925
Stencil and
Metallization
Component Outline
Component Outline
Solder Mask Opening
4X 0.075
SMT Pad Detail
Scale: 2X
3X This Rotation
3X Rotated 180o
5X Rotated 90o CW
5X Rotated 90o CCW
4X 0.925
Stencil Aperture
Top View
(4.3)
Pin 16
(8X 0.8 Pitch)
4.4
Pin 1
(0.9)
2
Component Outline
(4X 0.9 Pitch)
(0.9)
(4.3)
0
4.4
2
4X 0.8
Thermal Via Array.
mm on 0.6 mm pitch.
Additional vias in common
ground pad improve
thermal and electrical
performance.
4X 1.7
∅0.3
2X 1.825
Component Outline
0.25
Typ.
2X 1.825
0
4X 0.8
Solder Mask Opening
Top View
Metallization
Top View
Notes:
1. The cross-hatched area represents the merger of the center ground pad +4 individual I/O ground pads. All I/O ground
pads should have at least one via connected to internal ground planes for optimum electrical performance.
2. Thermal vias should be tented with solder mask, 30 to 35 mm Cu plating recommended.
3. All measurements are in millimeters
S2895
Figure 16. PCB Layout Footprint for the SKY66100-11 4 x 4 mm MCM
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
13
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Pin 1 Indicator
Pin 16
0
10X 1.9
B
4X 0.8
4
Pin 1
C
Pin 1 Indicator
See Detail D
10X 1.9
4X 0.8
A
0
4
4X 0.5375
16X SMT Pad
0.1 A B C
B
0.9 ± 0.1
0.15 A B C
0.1
Side View
Top View
(0.1)
Metal Pad Edges
0.2 X 0.2
0.925
0.925
0.4 ± 0.1
(0.1)
Detail A
Detail B
Pad
Scale: 2X
Pad
Scale: 2X
3X This rotation
3X Rotated 180°
3X Rotated 90° CW
3X Rotated 90° CCW
Solder Mask
Edges
(0.1)
Solder Mask Edges
0.4 ± 0.05
0.5 ± 0.05
Bottom View
0.4 ± 0.1
0.4 ± 0.01
Solder Mask
Edges
Solder Mask Openings
See Detail C
0.2 A B C
4X 0.5375
A
Metal Pad
Edges
0.925
0.925
3X Detail C
Detail D
Pad
Scale: 2X
Solder Mask
Edges
Pad
Scale: 2X
1X This rotation
1X Rotated 180°
1X Rotated 90° CW
1X Rotated 90° CCW
All measurements are in millimeters
Dimensioning and tolerancing according to ASME Y14.5M-1994
S2783
Figure 17. SKY66100-11 16-Pin MCM Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
14
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
2.00 ± 0.05
8.00 ± 0.10
0.30 ± 0.05 (T)
4.00 ± 0.10
∅1.50 ± 0.10
5.50 ± 0.05
A
4.40 (Bo)
A
B
1.70 (Ko)
12.00 + 0.30/–0.10
B
Pin 1
Indicator
B
1.75 ± 0.10
∅1.50 Min.
4.40 (Ao)
A
Notes:
1. Carrier tape material: black conductive polycarbonate or polystyrene.
2. Cover tape material: transparent conductive PSA.
3. Cover tape size: 9.3 mm width.
4. Ten sprocket hole pitch cumulative tolerance: ±0.20 mm.
5. Ao and Bo measured on plane 0.30 mm above the bottom of the pocket.
6. Typical ESD surface resistivity is ≤1 x 1010 Ohms/square per EIA, JEDEC
tape and reel specification.
7. All measurements are in millimeters
S2031
Figure 18. SKY66100-11 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201829E • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 1, 2015
15
DATA SHEET • SKY66100-11: TRANSMIT/RECEIVE FEM
Ordering Information
Model Name
SKY66100-11 TX/RX FEM (+24 dBm)
SKY66100-11 TX/RX FEM (+27 dBm)
Manufacturing Part Number
SKY66100-11
SKY66100-11
Evaluation Board Part Number
SKY66100-11-EK1
SKY66100-11-EK2
Copyright © 2012-2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
16
June 1, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201829E