DATA SHEET SKY65535-11: 5 GHz WLAN Front-End Module Applications 4B • WiFi-enabled handsets, tablets, and mobile/portable systems • System-in-Package (SIP) modules for embedded systems • WLAN-enabled wireless video systems Features 0B • Integrated high performance 5 GHz PA with harmonic filter, LNA with bypass, and SPDT • Fully-matched input and output • Integrated, positive slope power detector • Transmit gain: 30 dB • Receive gain: 12 dB • Output power: +17.5 dBm @ 3% EVM, 64 QAM 54 Mbps • Direct connection to battery with 3.6 V nominal supply voltage • Small, QFN (16-pin, 2.5 x 2.5 mm) package (MSL1, 260 °C per JEDEC J-STD-020) Figure 1. SKY65535-11 Block Diagram Description 1B The SKY65535-11 is a highly-integrated, 5 GHz Front-End Module (FEM) incorporating a 5 GHz Single-Pole, Double-Throw (SPDT) transmit/receive (T/R) switch, a 5 GHz Low-Noise Amplifier (LNA) with bypass, and a 5 GHz Power Amplifier (PA) intended for mobile/portable 802.11n applications and systems. The device operates from a single supply voltage of 3.6 V at +17.5 dBm of linear output power at the ANT port (pin 13) with a 64 QAM, 54 Mbps signal. An enable/disable function is included that allows power savings during off mode. An integrated power detector with 20 dB of dynamic range is included to provide closed-loop power control within the system. The device is provided in a compact, 16-pin 2.5 x 2.5 mm Quad Flat No-Lead (QFN) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Figure 2. SKY65535-11 Pinout – 16-Pin QFN (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201577G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 18, 2013 1 DATA SHEET • SKY65535-11 FRONT-END MODULE Technical Description Package and Handling Information 5B 6B The SKY65535-11 is comprised of a high performance 5 GHz PA, 5 GHz LNA, and broadband SPDT switch. The device is fullymatched, and requires few external components for optimal performance, which makes it ideal for small portable/mobile applications. The FEM provides up to +30 dB of gain over the frequency band. The LNA supports an enable/disable mode for power savings when not in receive mode and a bypass function for increased receive dynamic range. The PA can be shut off using the PA_EN signal (pin 6). Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. Electrical and Mechanical Specifications 2B Signal pin assignments and functional pin descriptions are described in Table 1. The absolute maximum ratings of the SKY65535-11 are provided in Table 2. The recommended operating conditions are specified in Table 3 and electrical specifications are provided in Tables 4, 5, and 6. The SKY65535-11 is rated to Moisture Sensitivity Level 1 (MSL1) at 260 °C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. The state of the SKY65535-11 is determined by the logic provided in Table 7. Table 1. SKY65535-11 Signal Descriptions Pin # Note: Name Description Pin # Name Description 1 GND Ground 9 N/C No connect 2 RX RF receive output 10 VCC1 Supply voltage 3 GND Ground 11 VCC2 Supply voltage 4 N/U Not used 12 GND Ground 5 VDET Detector output voltage 13 ANT Antenna 6 PA_EN PA enable 14 GND Ground 7 GND Ground 15 CRX Switch control voltage 8 TX RF transmit input 16 LNA_EN LNA enable N/C = No connect. Keep pin floating. N/U = Not used. Pin can be connected or left floating. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 March 18, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201577G DATA SHEET • SKY65535-11 FRONT-END MODULE Table 2. SKY65535-11 Absolute Maximum Ratings (Note 1) Parameter Symbol Minimum Maximum Units Supply voltage VCC –0.3 +5.5 V DC input on control pin (PA_EN, LNA_EN, CRX) VIN –0.3 +3.6 V Input power (ANT terminated in 50 Ω match) PIN +5 dBm Case operating temperature TA –40 +85 °C Storage temperature TST –40 +140 °C Electrostatic Discharge, Human Body Model (HBM), Class 1C ESD 1000 V Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. SKY65535-11 Recommended Operating Conditions Parameter Symbol Minimum Typical Maximum Units Supply voltage relative to GND = 0 V VCC 3.20 3.60 4.40 V Operating temperature TA –40 +25 +85 °C Table 4. SKY65535-11 Electrical Specifications: DC Characteristics (Note 1) (VCC = 3.6 V, PA_EN = 3.3 V, TA = 25 °C, All Unused Ports Terminated with 50 Ω, Unless Otherwise Noted) Parameter Supply current Symbol Test Condition ICC-A POUT = +17.5 dBm, 54 Mbps ICC-OFF PA_EN = 0 V, No RF applied, PA_EN = CRX = LNA_EN = 0 V Quiescent current ICQ No RF LNA supply current ICC_LNA LNA_EN = 3.3 V, CRX = 3.3 V LNA bypass supply current ICC_LNA_BYP LNA_EN = 0 V, CRX = 3.3 V Min Typical Max Units 190 mA 5 μA 120 9 mA 11 200 mA μA Note 1: Performance is guaranteed only under the conditions listed in this Table. T Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201577G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 18, 2013 3 DATA SHEET • SKY65535-11 FRONT-END MODULE Table 5. SKY65535-11 Electrical Specifications: General (Note 1) (VCC = 3.6 V, PA_EN = 3.3 V, LNA_EN = CRX = 0 V, TA = 25 °C, All Unused Ports Terminated with 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units 5950 MHz 3.2 % 3.0 % Transmit Characteristics Frequency range f Error Vector Magnitude EVM 5150 POUT = +17.5 dBm, 54 Mbps OFDM signal 3.0 POUT = +16.0 dBm, MCS7, HT40 Small signal gain S21 Harmonics (2nd and 3rd) 2fo, 3fo POUT = +19.5 dBm, 6 Mbps, 802.11a –45 dBm/MHz Delay and rise/fall time tDR, tDF 50% of VPA_EN edge and 90/10% of final output power level 400 ns Input return loss S11 @ TX port Stability Stab CW, PIN = +10 dBm, 0.1 GHz to 20 GHz, load VSWR = 6:1 All non-harmonically related outputs < –43 dBm/MHz CW, PIN = 0 dBm, 0.1 GHz to 20 GHz, load V SWR = 10:1 No permanent damage or performance degradation Ruggedness 30 dB –12 dB Receive Characteristics Frequency range f Small signal gain S21 Noise Figure NF 3rd Order Input Intercept Point IIP3 P P Input return loss S11 Output return loss S22 Enable time tEN Switch isolation ISOLSW 5150 5950 MHz LNA enabled +12 dB Bypass mode –7 dB 2.5 dB LNA enabled +3 dBm Bypass mode +20 dBm LNA enabled –10 dB Bypass mode –10 dB –8 10% to 90% of receive RF power, from time that LNA_EN is at 50% dB 400 20 ns dB Power Detector Characteristics Frequency range f Power detector range, CW PDR Output impedance PDZLOAD Output voltage PDVNO_RF PDVP10 PDVP23 Detector bandwidth PDBW Measured @ ANT pin 5150 5950 MHz 0 +23 dBm 2.2 kΩ POUT = no RF, measured in to 1 MΩ 0.1 V POUT = +10 dBm, CW, measured in to 1 MΩ 0.2 V POUT = +23 dBm, CW, measured in to 1 MΩ 0.8 V 1 MHz Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 March 18, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201577G DATA SHEET • SKY65535-11 FRONT-END MODULE Table 6. SKY65535-11 Electrical Specifications: Control Logic Characteristics (Note 1) (VCC = 3.6 V, PA_EN = 3.3 V, LNA_EN = CRX = 0 V, TA = 25 °C, All Unused Ports Terminated with 50 Ω, Unless Otherwise Noted) Parameter Symbol Control voltage: High Low VIH VIL Input current, high IIH Input current, low IIL Test Condition Min Typical 1.6 0 All pins except PEN PEN pin Max Units 3.6 0.4 V V 10 200 μA μA 1 μA Table 7. SKY65535-11 Control Logic Mode CRX (Pin 15) LNA_EN (Pin 16) (Note 1) PA_EN (Pin 6) (Note 2) WLAN receive 1 1 0 WLAN receive bypass mode 1 0 0 WLAN transmit 0 0 1 WLAN off 0 0 0 Note 1: LNA is on while LNA_EN is high. LNA is off and in bypass mode when LNA_EN is low. Note 2: PA_EN controls PA enable and transmit/receive switch logic. Evaluation Board Description Circuit Design Considerations The SKY65535-11 Evaluation Board is used to test the performance of the SKY65535-11 FEM. A suggested application schematic diagram is shown in Figure 3. A photograph of the Evaluation Board is shown in Figure 4. The following design considerations are general in nature and must be followed regadless of final use or configuration: 7B Evaluation Board Test Procedures 1. Connect the system ground to connector J4, pin 2, of the Evaluation Board. 2. Apply 3.6 V to connector J4, pins 1 and 3. 3. Apply 3.3 V to connector J5, pin 1. 4. Select a path to test according to the modes shown in Table 7. 5. Connect a multimeter or oscilloscope to connector J5, pin 12, to monitor the power detector voltage. 6. Apply an RF signal to connector J1 (ANT) to monitor the RX to ANT performance. Measure the response from the output of connector J2 (RX). 9B 7. Apply an RF signal to connector J3 (TX) to monitor the ANT to TX performance. Monitor the output power on connector J1 (ANT). Care should be taken not to overdrive the amplifier by applying too much RF on the input to the device (–20 dBm provides a suitable starting input power for the device). 1. Paths to ground should be made as short as possible. 2. The RX and ANT ports are AC-coupled and do not require DC blocking capacitors. The TX port (pin 8) has an on-chip inductor to ground followed by a DC blocking capacitor between the inductor and the die. Therefore, there is no DC present on this port. 3. If the TX port is connected to an external component with DC present on it, a 10 pF (component C8) general purpose blocking capacitor is recommended. 4. Capacitors C6 (1 μF) and C7 (100 pF) should be on the primary side of the Evaluation Board at a minimum manufacturable distance from the FEM. 5. The ground pad of the SKY65535-11 has special electrical and thermal grounding requirements. This pad is the main thermal conduit for heat dissipation. Since the circuit board acts as the heat sink, it must shunt as much heat as possible from the device. Therefore, design the connection to the ground pad to dissipate the maximum wattage produced by the circuit board. Multiple vias to the grounding layer are required. 6. Trace losses are as shown in Table 8. NOTE: A poor connection between the slug and ground increases junction temperature (TJ), which reduces the lifetime of the device. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201577G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 18, 2013 5 DATA SHEET • SKY65535-11 FRONT-END MODULE Package Dimensions 3B The PCB layout footprint for the SKY65535-11 is shown in Figure 5. Typical case markings are shown in Figure 6. Package dimensions for the 16-pin QFN are shown in Figure 7, and tape and reel dimensions are provided in Figure 8. Table 8. Evaluation Board Trace Losses Trace Losses (dB) Trace TX path @ 4.9 GHz @ 5.4 GHz @ 5.9 GHz 0.28 0.25 0.37 RX path 0.15 0.19 0.20 ANT path 0.15 0.19 0.20 Figure 3. SKY65535-11 Application Schematic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 March 18, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201577G DATA SHEET • SKY65535-11 FRONT-END MODULE Figure 4. SKY65535-11 Evaluation Board Assembly Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201577G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 18, 2013 7 DATA SHEET • SKY65535-11 FRONT-END MODULE Figure 5. SKY65535-11 PCB Layout Footprint Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 March 18, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201577G DATA SHEET • SKY65535-11 FRONT-END MODULE Figure 6. Typical Case Markings (Top View) Figure 7. SKY65535-11 16-Pin QFN Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201577G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 18, 2013 9 DATA SHEET • SKY65535-11 FRONT-END MODULE Figure 8. SKY65535-11 Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 10 March 18, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201577G DATA SHEET • SKY65535-11 FRONT-END MODULE Ordering Information 8B Model Name SKY65535-11 5 GHz Front-End Module Manufacturing Part Number SKY65535-11 Evaluation Board Part Number SKY65535-11-EVB Copyright © 2011, 2012, 2013 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201577G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 18, 2013 11