SKY66101_11_202884D.pdf

DATA SHEET
SKY66101-11: 902 to 928 MHz High-Power RF
Front-End Module
CPS
CTX
CSD
ANT_SEL
Applications
 Range extender
 Smart meters
 In-home appliances
 Smart thermostats
Logic
Control
PA_IN
PA
ANT1
Features
 Integrated PA with +30 dBm output power
 Integrated LNA with programmable bypass
RXP
 Low noise figure: 2.5 dB, typical
RXN
LNA
ANT2
LNA _IN
 Differential 100 Ω receive RF interface
 Fast turn-on/turn-off time: <1 μs
 Supply voltage: 2.0 V to 4.8 V
 Small MCM (36-pin, 6 x 6 x 0.9 mm) package
(MSL3, 260 C per JEDEC J-STD-020)
Description
GND
VSUP1
GND
VCC1
GND
VCC0
GND
VCC2
GND
36
35
34
33
32
31
30
29
28
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
CSD
1
27
GND
23
GND
N/C
6
22
GND
PA_IN
7
21
GND
CPS
8
20
ANT_1
CTX
9
19
GND
ANT2
GND
RX_FLT
GND
LNA_IN
GND
GND
18
5
17
GND
GND
16
24
15
4
14
GND
RX_P
13
GND
25
12
26
3
11
2
10
GND
RX_N
GND
202884D-001
Figure 1. SKY66101-11 Functional Block Diagram
 Sleep mode current: < 1 μA
ANT_SEL
Rx_FLT
 Single-ended 50 Ω transmit RF interface
202884D-002
The SKY66101-11 is a high-performance, highly integrated RF
front-end module (FEM) designed for high-power Industrial,
Scientific, Medical (ISM) band applications operating in the
902 to 928 MHz frequency range.
The SKY66101-11 is designed for ease of use and maximum
flexibility with fully matched, 50 Ω power amplifier (PA) input and
output, and digital controls compatible with 1.6 to 3.6 V CMOS
levels.
The RF blocks operate over a wide supply voltage range from
2.0 to 4.8 V that allows the SKY66101-11 to be used in battery
powered applications over a wide spectrum of the battery
discharge curve.
The SKY66101-11 is packaged in a 36-pin, 6 x 6 x 0.9 mm MultiChip Module (MCM), which allows for a highly manufacturable
low-cost solution.
A functional block diagram of the SKY66101-11 is shown in
Figure 1. The 36-pin MCM package and pinout are shown in
Figure 2. Signal pin assignments and functional pin descriptions
are provided in Table 1.
Figure 2. SKY66101-11 Pinout
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202884D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 3, 2016
1
DATA SHEET • SKY66101-11: HIGH-POWER RF FEM
Table 1. SKY66101-11 Signal Descriptions
Pin
Description
Pin
CSD
Standby control (see Table 9)
19
GND
Ground
2
GND
Ground
20
ANT1
Antenna 1 (integrated harmonic filtering)
3
RX_N
Receive RF output, negative polarity (100 Ω
differential)
21
GND
Ground
4
RX-P
Receive RF output, positive polarity (100 Ω
differential)
22
GND
Ground
5
GND
Ground
23
GND
Ground
6
N/C
No connection
24
GND
Ground
7
PA_IN
PA input
25
GND
Ground
8
CPS
LNA gain control (see Table 9)
26
GND
Ground
9
CTX
Transmit/receive control (see Table 9)
27
GND
Ground
10
ANT_SEL
Antenna select control (see Table 9)
28
GND
Ground
11
GND
Ground
29
VCC2
PA voltage supply
12
GND
Ground
30
GND
Ground
13
GND
Ground
31
VCC0
Decoupling capacitor
14
LNA_IN
LNA input
32
GND
Ground
1
Name
Name
Description
15
GND
Ground
33
VCC1
PA voltage supply
16
RX_FLT
Receive signal from antennas
34
GND
Ground
17
GND
Ground
35
VSUP1
PA voltage supply
18
ANT2
Antenna 2 (no integrated harmonic filtering)
36
GND
Ground
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
March 3, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202884D
DATA SHEET • SKY66101-11: HIGH POWER RF FEM
Technical Description
The SKY66101-11 consists of a complete T/R chain with T/R
switches contained in the module. An SP3T switch selects
between receive, transmit, and transmit bypass paths. The
module has a shutdown mode to minimize power consumption.
The transmit path contains a PA optimized for saturated
performance. The PA can be passed through an external
impedance matching network and harmonic filter before being fed
through the SP3T switch. External inductors for each of the two
PA stages provide maximum application flexibility.
Three digital input control pins (CSD, CPS, and CTX) are used to
select between shutdown, T/R, or transmit bypass mode,
respectively. A fourth digital control pin (ANT_SEL) is used to
select between antenna ports 1 and 2.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY66101-11 are provided
in Table 2. The recommended operating conditions are specified
in Table 3 and electrical specifications are provided in Tables 4
through 8.
The bypass mode can also be configured to power-down the PA
and remove it from the RF path using an internal single-pole,
single-throw (SPST) switch.
The state of the SKY66101-11 is determined by the logic provided
in Table 9.
Table 2. SKY66101-11 Absolute Maximum Ratings1
Parameter
Symbol
Supply voltage (no RF)
Minimum
Maximum
Units
–0.3
+5.5
V
–0.3
+3.6
V
C
VCC
Control pin (CSD, CPS, CTX, and ANT_SEL) voltages
Operating temperature
TA
–40
+85
Storage temperature
TSTG
–40
+125
C
Transmit RF input power
PIN_TX_MAX
+10
dBm
Receive RF input power @ ANT1 or ANT2 ports
PIN_RX_MAX
+15
dBm
Voltage Standing Wave Ratio @ ANT1 or ANT2 ports
VSWR
10:1
–
Electrostatic discharge:
ESD
250
1000
50
V
V
V
Charged Device Model (CDM), Class 2
Human Body Model (HBM), Class 1C
Machine Model (MM), Class A
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set
at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY66101-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply voltage
VCC
2.0
3.6
4.8
V
Operating temperature
TA
–40
+25
+85
C
50
%
Transmit duty cycle
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202884D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 3, 2016
3
DATA SHEET • SKY66101-11: HIGH-POWER RF FEM
Table 4. SKY66101-11 DC Electrical Specifications1
(VCC = +3.6 V, TA = +25 C, as Measured on the SKY66101-11 Evaluation Board [De-Embedded to Device], Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
POUT = +30 dBm
POUT = +27 dBm
POUT = +24 dBm
Typical
Max
Units
670
475
340
mA
mA
mA
6
mA
Total supply current, transmit mode2
ICC_TX30
ICC_TX27
ICC_TX24
Total supply current, receive mode
ICC_RX
Total supply current, receive bypass mode
ICC_RXB
Quiescent current
ICQ_TX
No RF
50
Sleep supply current
ICC_OFF
No RF
0.05
250
μA
mA
1.00
μA
1 Performance is guaranteed only under the conditions listed in this table.
2 ICC_TX27 and ICC_TX24 are not production tested.
Table 5. SKY66101-11 Receive Mode Electrical Specifications1
(VCC = +3.6 V, TA = +25 C, as Measured on the Evaluation Board [De-Embedded to Device], All Unused Ports Terminated with 50 Ω,
Unless Otherwise Noted. Input Ports: ANT1 or ANT2, Output Port: RX_N/RX_P, 0 Ω Connected between the RX_FLT and LNA_IN Pins in lieu
of External Filters)
Parameter
Symbol
Frequency range
f
Gain
RX_GAIN
Noise Figure2
NF
Test Condition
Min
Typical
902
Max
Units
928
MHz
16
dB
2.5
dB
900 to 930 MHz
Third order input intercept point2
IIP3
–5
–2
dBm
1 dB input compression point
IP1dB
–12
–9
dBm
Gain in receive bypass mode
G_RXB
–4.5
–3
dB
1 dB input compression point in receive
bypass mode2
IP1dB_RXB
+9
dBm
S11
900 to 930 MHz,
into 50 Ω, ANT1 and
ANT2 ports
–8
dB
tON
From 50% of CTX edge to
90% of final RF output
power
1
μs
From 50% of CTX edge to
10% of final RF output
power
1
μs
Antenna port return loss
Turn-on time2
tOFF
Turn-off time2
–12
1 Performance is guaranteed only under the conditions listed in this table.
2 Not production tested.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
March 3, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202884D
DATA SHEET • SKY66101-11: HIGH POWER RF FEM
Table 6. SKY66101-11 Transmit Mode Electrical Specifications1
(VCC = +3.6 V, TA = +25 C, POUT = +30 dBm, as Measured on the Evaluation Board [De-Embedded to Device], All Unused Ports
Terminated with 50 Ω, Unless Otherwise Noted. Input Port: PA_IN, Outport Ports: ANT1 and ANT2)
Parameter
Symbol
Test Condition
Min
Typical
Frequency range
f
Output power @ ANT1 port2
POUT
VCC = 4.0 V
VCC = 3.6 V
VCC = 3.0 V
Small signal gain
S21
@ 902 to 928 MHz
33
Output return loss
S22
50 Ω, ANT1 and ANT2 ports
–10
2nd harmonic
2fo
3 to 10 harmonic3
rd
th
3fo to 10fo
Turn-on time4
tON
Turn-off time4
tOFF
Stability4
Stab
Ruggedness4
RU
902
Max
Units
928
MHz
dBm
dBm
dBm
+31
+30
+28
dB
–7
dB
POUT = +30 dBm,CW into 50 Ω,
ANT1 and ANT2 ports
–22
dBc
POUT = +30 dBm, CW:
ANT1
ANT2
–72
–45
dBc
dBc
From 50% of CTX edge to 90% of
final RF output power
1
μs
From 50% of CTX edge to 10% of
final RF output power
1
μs
@ 0.1 to 20 GHz, CW,
POUT = +30 dBm,
load VSWR = 6:1
All non-harmonically related outputs < –43 dBm
CW, POUT = +30 dBm into 50 Ω
load, VSWR = 10:1
No permanent damage
1 Performance is guaranteed only under the conditions listed in this table.
2 Production tested at VCC = 3.6 V only.
3 Only the 2nd to 5th harmonics at ANT1 are production tested. The 6th to 10th harmonics are characterized only.
4 Not production tested.
Table 7. SKY66101-11 Diversity Antenna Electrical Specifications1
(VCC = +3.6 V, TA = +25 C, f = 900 MHz to 930 MHz, as Measured on the Evaluation Board [De-Embedded to Device], All Unused Ports
Terminated with 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Isolation between ANT1 and ANT2 ports
ISO_ANTSW
28
dB
Insertion loss from ANT1 to RX_FLT port (Note 2)
RX_ANT1
1.0
dB
Insertion loss from ANT2 to RX_FLT port (Note 2)
RX_ANT2
1.0
dB
ANT1 to ANT2 switching time, transmit mode (Note 2)
TANT1-ANT2_TX
800
ns
ANT1 to ANT2 switching time, receive mode (Note 2)
TANT1-ANT2_RX
400
ns
1 Performance is guaranteed only under the conditions listed in this table.
2 Not production tested.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202884D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 3, 2016
5
DATA SHEET • SKY66101-11: HIGH-POWER RF FEM
Table 8. SKY66101-11 Electrical Specifications: Control Logic Characteristics1
(TA = +25 C, as Measured on the SKY66101-11 Evaluation Board [De-Embedded to Device], Unless Otherwise Noted)
Parameter
Symbol
Control voltage (Note 2):
High
Low
VIH
VIL
Input current (Note 2):
High
Low
IIH
IIL
Test Condition
Min
Typical
1.6
0
Max
Units
3.6
0.3
V
V
1
1
μA
μA
1 Performance is guaranteed only under the conditions listed in this table.
2 Not production tested.
Table 9. SKY66101-11 Mode Control Logic1
CPS
(Pin 8)
CSD
(Pin 1)
CTX
(Pin 9)
ANT_SEL
(Pin 10)
Sleep (all off)
0
0
0
X
Receive bypass
0
1
0
X
Receive LNA mode
1
1
0
X
Mode
Transmit
X
1
1
X
ANT1 port enabled
X
X
X
0
ANT2 port enabled
X
X
X
1
1 “1” = 1.6 to 3.6 V, “0” = 0 to 0.3 V, “X” = don’t care.
Evaluation Board Description
Package and Handling Information
The SKY66101-11 Evaluation Board is used to test the
performance of the SKY66101-11 front-end module. An
Evaluation Board schematic diagram is provided in Figure 3. An
assembly drawing for the Evaluation Board is shown in Figure 4,
and the layer detail information is provided in Figure 5.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
Package Dimensions
Figure 6 shows the package dimensions, and Figure 7 provides
the tape and reel dimensions.
The SKY66101-11 is rated to Moisture Sensitivity Level 3 (MSL3)
at 260 C. It can be used for lead or lead-free soldering. For
additional information, refer to the Skyworks Application Note,
PCB Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
March 3, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202884D
1
3
5
7
9
11
13
15
17
19
DATA SHEET • SKY66101-11: HIGH POWER RF FEM
C6
33 pF
L4
6.8 nH
L3
3.3 nH
CSD
VCC
CPS
CTX
ANT_SEL
2
4
6
8
10
12
14
16
18
20
J5
C9
4.7 μF
C7
1 nF
C5
1.5 nF
C3
68 pF
HHM1523C1
1 UN_BAL
2 RF_GND
3 BAL_PT
J4
SMA
N/C
GND
BAL_PT
6
5
4
CSD
U1
CPS
CTX
CSD
GND
RX_N
RX_P
GND
N/C
PA_IN
CPS
CTX
36
35
34
33
32
31
30
29
28
SKY66101
U2
GND
GND
GND
GND
GND
GND
GND
ANT_1
GND
27
26
25
24
23
22
21
20
19
J1
SMA
10
11
12
13
14
15
16
17
18
ANT_SEL
GND
GND
GND
LNA_IN
GND
RX_FLT
GND
ANT2
J3
SMA
1
2
3
4
5
6
7
8
9
C1
1 pF
GND
VSUP1
GND
VCC1
GND
VCC0
GND
VCC2
GND
PAD
37
C8
22 pF
ANT_SEL
PCB Recommendations:
Metal Layer 1 = RF traces + control lines. Core thickness between top RF layer and ground plane is critical.
Metal Layer 2 = Solid ground plane. No traces routing.
Metal Layer 3 and 4 = Control lines + VCC traces (no VCC plane).
Pour copper on each layer connected to the ground plane. Use VCC traces in a star distribution pattern.
Always use 4 layers.
J2
SMA
202884D--003
Figure 3. SKY66101-11 Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202884D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 3, 2016
7
DATA SHEET • SKY66101-11: HIGH-POWER RF FEM
J5
C9
L3
L4
C7
C6
C8
C3
J4
U1
C5
C1
U2
J1
J3
J2
202884D-004
Figure 4. SKY66101-11 Evaluation Board Assembly Drawing
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
March 3, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202884D
DATA SHEET • SKY66101-11: HIGH POWER RF FEM
Layer Two
202884D-005
Top Layer
Layer Three
Bottom Layer
Figure 5. SKY66101-11 Evaluation Board Layer Details
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202884D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 3, 2016
9
0.1 M A B C
Pin 36
0
Pin 1
Indicator
36X SMT Pad
Mold
B
4X 2
6
10X 1
DATA SHEET • SKY66101-11: HIGH-POWER RF FEM
Pin 1 Indicator
See Detail C
C
Pin 1
MCM Substrate
4X 2
4X 1.5
10X 1
4X 0.5
6
0
See Detail A
Solder Mask Opening
0.15 A B C
0.08
0.025 A
Top View
4X 0.5
4X 1.5
A
0.9 ±0.1
0.05 A B C
Side View
0.5 ±0.075
Bottom View
(0.1)
0.875
0.875
Pin 1 Indicator
Notes:
0.2 x 0.2
1. Dimensions and tolerances in accordance with ASME Y14.5M–1994.
2. Dimensions are in millimeters (unless otherwise specified).
3. Tolerances on:
Decimals
Angles
.XX = ±.05
±.30°
.XXX = ±.025
0.25 ±0.025
0.4 ±0.03
0.875
0.875
5X R0.05 Max
Metal Pad Edge
4X R0.05 Max
Detail A
Pad
Scale: 2X
9X this rotation
9X rotated 180°
9X rotated 90° CW
9X rotated 90° CCW
Detail B
Detail C
SMT Pad
Scale: 2X
8X
SMT Pad
Scale: 2X
Figure 6. SKY66101-11 Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
March 3, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202884D
202884D-006
DATA SHEET • SKY66101-11: HIGH POWER RF FEM
Ø1.55
8.00 (P1)
± 0.05
4.00 (Po)
2.00 ± 0.05
B
1.75 ± 0.10
5.50 ± 0.05
Pin 1
A
6.30 (Bo)
A
12.00 ± 0.30
0.3 ± 0.05
5 ° Max.
1.35 (Ko)
B
Ø1.50 Min
Detail B
6.30 (Ao)
5 ° Max.
Notes:
1.
2.
3.
5.
6.
Carrier tape material: Black conductive polycarbonate.
Cover tape material: Transparent conductive.
Po/P1 0 pitches cumulative tolerance: ± 0.20 mm.
Ao and Bo measured on plane 0.30 mm from bottom pocket.
All dimensions are in millimeters.
Detail A
202884D-007
Figure 7. SKY66101-11 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202884D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 3, 2016
11
DATA SHEET • SKY66101-11: HIGH-POWER RF FEM
Ordering Information
Model Name
SKY66101-11: High-Power RF Front-End Module
Manufacturing Part Number
SKY66101-11
Evaluation Board Part Number
SKY66101-11-EK1
Copyright © 2013-2014, 2016 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12