SKY13290-313LF 0.5-2.5 GHz, 10 W pHEMT SPDT Switch

DATA SHEET
SKY13290-313LF: 20 MHz-2.5 GHz, 10 W pHEMT SPDT
Switch
Applications
• Transmit/receive switching for telematic systems at elevated
power levels
Features
• Broadband frequency range: 20 MHz to 2.5 GHz
• Very low insertion loss, 0.4 dB typical @ 0.9 GHz
• High isolation: 26 dB typical @ 0.9 GHz
• High input power compression: 0.1 dB @ > +40 dBm
• Low current consumption: <100 μA @ 3 V
• Ultra-miniature, QFN (6-pin, 2 x 3 mm) package
(MSL1, 260 °C per JEDEC J-STD-020)
Figure 1. SKY13290-313LF Block Diagram
Description
The SKY13290-313LF is a high power, pHEMT Single Pole Double
Throw (SPDT) switch. The switch is designed for use in systems
operating from 20 MHz to 2.5 GHz for which low loss, high
isolation, low control voltage, and ultra-miniature package size
are required.
The device is controlled with positive, negative, or a combination
of both voltages. The RF signal paths within the device are fully
bilateral.
The SKY13290-313LF is manufactured in a compact, low-cost
2 x 3 mm, 6-pin Quad Flat No-Lead (QFN) package. A functional
block diagram is shown in Figure 1. The pin configuration and
package are shown in Figure 2. Signal pin assignments and
functional pin descriptions are provided in Table 1.
Figure 2. SKY13290-313LF Pinout –6-Pin QFN
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200488G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 11, 2013
1
DATA SHEET • SKY13290-313LF SPDT SWITCH
Table 1. SKY13290-313LF Signal Descriptions
Pin #
Name
Description
Pin #
Name
Description
1
J2
RF input/output. According to the logic
voltage levels applied to the V1 and V2 pins,
this port is either connected to J1 using a
low insertion loss path or isolated from J1
(Note 1).
4
V2
DC control voltage input #2. The logic
voltage applied to this pin, along with the
voltage level applied to the V1 pin,
determines the states of the RF paths
between J1/J2 and J1/J3.
2
GND
Ground. Equipotential port, internal circuit
common, which must connected to the PCB
ground or common using the lowest
possible impedance.
5
J1
RF input/output. According to the logic
voltage levels applied to the V1 and V2 pins,
this port is either connected to J2 or to J3
using a low insertion loss path and isolated
from the other RF port (Note 1).
3
J3
RF input/output. According to the logic
voltage levels applied to the V1 and V2 pins,
this port is either connected to J1 using a
low insertion loss path or isolated from J1
(Note 1).
6
V1
DC control voltage input #1. The logic
voltage applied to this pin, along with the
voltage level applied to the V2 pin,
determines the states of the RF paths
between J1/J2 and J1/J3.
Note 1: A 47 pF blocking capacitor is required for >500 MHz operation. Use larger value capacitors for lower frequency operation.
Table 2. SKY13290-313LF Absolute Maximum Ratings
Parameter
Symbol
Control voltage
VCTL
RF input power (VCTL > 0.9 GHz)
PIN
Operating temperature
TOP
Storage temperature
TSTG
Electrostatic Discharge, Human Body Model (HBM), Class 1A
Note:
Minimum
0
Maximum
Units
+10
V
+43.5
dBm
–40
+85
°C
–65
+150
°C
250
V
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Technical Description
Electrical and Mechanical Specifications
The SKY13290-313LF is controlled using two voltage inputs, V1
and V2 (pins 6 and 4, respectively). Depending on the voltage level
applied to these pins, the common RF port (J1) is connected to
one of two RF ports (J2 or J3) using a low insertion loss path,
while the path between J1 and the other RF port is in its isolation
state.
The absolute maximum ratings of the SKY13290-313LF are
provided in Table 2. Electrical specifications are provided in
Table 3 and the operating characteristics are specified in Table 4.
When the control voltages are toggled, the states between J1 and
J2, as well as J1 and J3, are also toggled.
Typical performance characteristics of the SKY13290-313LF are
illustrated in Figures 3 through 6.
The state of the SKY13290-313LF is determined by the logic
provided in Table 5.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
March 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200488G
DATA SHEET • SKY13290-313LF SPDT SWITCH
Table 3. SKY13290-313LF Electrical Specifications (Note 1)
(VCTL = 0-3 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Insertion loss
0.02 to 1.0 GHz
1.0 to 2.0 GHz
2.0 to 2.5 GHz
Isolation
0.02 to 1.0 GHz
1.0 to 2.0 GHz
2.0 to 2.5 GHz
Return loss (Note 2)
Switching characteristics:
Rise/fall
On/off
0.1 dB Input Compression Point
IP0.1dB
Min
23
17
15
Max
Units
0.40
0.45
0.55
0.50
0.60
0.70
dB
dB
dB
26
20
18
dB
dB
dB
0.02 to 1.0 GHz
1.0 to 2.5 GHz
20
20
dB
dB
10/90% or 90/10% RF
50% VCTL to 90/10% RF
650
800
ns
ns
+37.6
+40.5
dBm
dBm
45
°C/W
@ 48 MHz
@ 900 MHz
Thermal resistance
Control voltage:
Low (@ 20 μA max)
High (@100 μA max)
High (@ 200 μA max)
Typical
VCTL_L
VCTL_H
VCTL_H
0
2.7
10.0
V
V
V
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Return loss state. Lower frequency return loss is dependent on value of the DC blocking capacitors.
Typical Performance Characteristics
(VCTL = 0-3 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, CBL = 100 pF, Unless Otherwise Noted)
Figure 3. Insertion Loss vs Frequency
Figure 4. Isolation vs Frequency
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200488G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 11, 2013
3
DATA SHEET • SKY13290-313LF SPDT SWITCH
Figure 6. Insertion Loss vs Input Power
(@ 900 MHz)
Figure 5. Return Loss vs Frequency
(Insertion Loss State)
Table 4. Truth Table (VHIGH = 2 to 5 V)
V1
V2
VLOW
VHIGH
Note:
J1-J2
J1-J3
VHIGH
Isolation
Insertion loss
VLOW
Insertion loss
Isolation
VLOW = 0 to 0.2 V, VHIGH = 2.7 to 10 V. Any state other than described in this Table places the device in an undefined state. An undefined state does not damage the device.
Evaluation Board Description
Package and Handling Information
The SKY13290-313LF Evaluation Board is used to test the
performance of the SKY13290-313LF SPDT switch. An Evaluation
Board schematic diagram is provided in Figure 7. An assembly
drawing for the Evaluation Board is shown in Figure 8.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Package Dimensions
The PCB layout footprint for the SKY13290-313LF is shown in
Figure 9. Typical case markings are shown in Figure 10. Package
dimensions for the 6-pin QFN are shown in Figure 11, and tape
and reel dimensions are provided in Figure 12.
The SKY13290-313LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 °C. It can be used for lead or lead-free soldering.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
March 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200488G
DATA SHEET • SKY13290-313LF SPDT SWITCH
Figure 7. SKY13290-313LF Evaluation Board Schematic
Figure 8. SKY13290-313LF Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200488G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 11, 2013
5
DATA SHEET • SKY13290-313LF SPDT SWITCH
Figure 9. SKY13290-313LF PCB Layout Footprint
Figure 10. Typical Case Markings
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
March 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200488G
DATA SHEET • SKY13290-313LF SPDT SWITCH
Figure 11. SKY13290-313LF 6-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200488G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 11, 2013
7
DATA SHEET • SKY13290-313LF SPDT SWITCH
Figure 12. SKY13290-313LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
March 11, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200488G
DATA SHEET • SKY13290-313LF SPDT SWITCH
Ordering Information
Model Name
SKY13290-313LF SPDT Switch
Manufacturing Part Number
SKY13290-313LF
Evaluation Board Part Number
SKY13290-313LF-EVB
Copyright © 2002-2007, 2010, 2013 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200488G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 11, 2013
9