Data Sheets - Skyworks Solutions, Inc.

DATA SHEET
SKY65364-11: 900 MHz Transmit/Receive Front-End Module
Applications
Description
• Automated meter reading
Skyworks SKY65364-11 is a high performance, transmit/receive
(T/R) Front-End Module (FEM). The device provides a complete
T/R chain with T/R switches.
• Advanced metering infrastructure
• ISM systems
The device transmit chain features +30.5 dBm output power and
a 40 percent Power Added Efficiency (PAE).
Features
• Transmit output power > +30.5 dBm
• High efficiency PA
• Analog power control
• Receive path NF <2.1 dB
• PA bypass mode
• LNA low current mode with external resistor
• LNA bypass mode
• Integrated control logic
• Internal RF match and bias circuits
• All RF ports internally DC blocked
• Shutdown mode
• Small footprint, MCM (28-pin, 6 x 6 mm) package (MSL3,
260 °C per JEDEC J-STD-020)
The device receive chain features a Low Noise Amplifier (LNA)
with a 1.7 dB Noise Figure (NF) and 16.0 dB gain. The cascaded
NF and gain, taking into account the 0.5 dB insertion loss
transmit/receive antenna switch, are 2.2 dB and 15.5 dB,
respectively, which makes the SKY65364-11 ideal for medium
power microwave links such as 900 MHz Industrial, Scientific,
and Medical (ISM) band applications.
The module also has a shut-down mode, PA bypass mode, and
LNA bypass mode to minimize power consumption.
The device is mounted in a 28-pin, 6 x 6 mm Multi-Chip Module
(MCM) Surface-Mounted Technology (SMT) package, which
allows for a highly manufacturable low-cost solution.
The device package and pinout for the 28-pin MCM are shown in
Figure 1. A block diagram of the SKY65364-11 is shown in
Figure 2. Signal pin assignments and functional pin descriptions
are provided in Table 1.
Figure 1. SKY65364-11 Pinout – 28-Pin MCM
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
1
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Figure 2. SKY65364-11 Block Diagram
Table 1. SKY65364-11 Signal Descriptions
Pin #
Name
Description
Pin #
Name
Description
1
GND
Ground
15
GND
Ground
2
TR
Digital control input: transmit/receive mode
16
VDD1
3.3 V power supply
3
EN
Digital control input: shutdown mode
17
VCC_RX
3.3 V power supply
4
BYP
Digital control input: receive bypass mode
18
RXO
Receive output
5
VPC
Transmit output power adjustment
19
GND
Ground
6
GND
Ground
20
TX
Transmit path input port. Internally matched
to 50 Ω.
7
ANT
Antenna switch common port. Internally
matched to 50 Ω.
21
GND
Ground
8
GND
Ground
22
GND
Ground
9
GND
Ground
23
VDD2
3.6 V power supply
10
RX1
Receive arm of antenna switch. Internally
matched to 50 Ω.
24
VCC_TX1
3.6 V power supply
11
GND
Ground
25
VCC_TX2
3.6 V power supply
12
GND
Ground
26
VCC_TX3
3.6 V power supply
13
RX2
LNA and bypass switch output port.
Internally matched to 50 Ω.
27
GND
Ground
14
RBIAS
LNA bias setting resistor
28
GND
Ground
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Technical Description
Receive Path
The SKY65364-11 consists of a complete T/R chain with T/R
switches contained in the module. A Single-Pole Triple-Throw
(SP3T) switch selects between the receive, transmit, and transmit
bypass paths. The module has a shut-down mode to minimize
power consumption.
The receive path contains an LNA with bypass switch. The LNA
impedance matching networks are internal to the module and
have been optimized for a low NF while maintaining good return
losses into a 50 Ω source and load impedance. The receive arm
of the SP3T switch and the LNA input are connected to module
pins to allow an external filter to be inserted into the receive path.
Three digital input pins (EN, TR, and BYP) are used to select
between transmit, transmit bypass, receive, receive bypass, or
shutdown mode.
LNA biasing can be independently lowered with an external bias
resistor between the RBIAS pin and ground.
Transmit Path
Operation Mode Control
The transmit path contains a Power Amplifier (PA) optimized for
saturated performance. The PA output is internally matched for
optimum output power and efficiency into a 50 Ω load
impedance. The PA output is passed through an harmonic filter
before being fed through the SP3T switch. The PA input provides
a good return loss into a 50 Ω source impedance.
The five SKY65364-11 operating modes are controlled by the
three digital pins TR, EN, and BYP (pins 2, 3, and 4, respectively).
The control logic truth Table is provided in Table 2.
Transmit output power is controlled by the VPC pin, which is
normally set to 2.25 V DC voltage. The nominal DC input
impedance into the VPC pin is 50 kΩ.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY65364-11 are provided
in Table 3. Recommended operating conditions are specified in
Table 4. Electrical specifications are provided in Tables 5, 6, and
7.
Typical performance characteristics of the SKY65364-11 are
illustrated in Figures 3 through 17.
Table 2. SKY65364-11 Operating Modes Truth Table (Note 1)
Control Voltage
Operating Mode
Internal States
TR
(Pin 2)
EN
(Pin 3)
BYP
(Pin 4)
PA
LNA
LNA Bypass
Switch
T/R Switch
PA Bypass
Switch
Transmit
1
1
0
On
Off
Open
PA
PA
Transmit bypass
1
1
1
Off
Off
Open
PA bypass
PA bypass
Receive
0
1
0
Off
On
Open
RX1
Open
Receive Bypass
0
1
1
Off
Off
Through
RX1
Open
Shutdown (Note 2)
X
0
X
Off
Off
Open
Open
Open
Note 1: See Recommended Operating Conditions Table for logic 0 and 1 characteristics. “X” = don’t care state, defined as a valid state of logic 1 or 0.
Note 2: In the high state, EN, TR, and BYP have an input current of 33 μA due to an internal 100 kΩ pulldown resistance. For the lowest leakage current, the high state is not recommended for
TR and BYP when the device is in shutdown mode (EN = 0).
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
3
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Table 3. SKY65364-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
–0.3
+5.0
V
20
mA
–0.3
+6.0
V
1.6
A
LNA supply voltage
VCC_RX
LNA supply current
ICC_RX
PA supply voltage
VCC_TX1/2/3
PA supply current
ICC_TX
Digital supply voltage
VDD1
–0.5
+5.5
V
Digital supply voltage
VDD2
–0.5
+5.5
V
Digital control voltage (EN, TR, BYP)
VCTL
–0.5
VDD1 + 0.3
V
Transmit output power control voltage
VPC
–0.3
+5.0
V
Receive RF input power (RX2)
PIN_RX2
+5
dBm
Receive RF input power (ANT)
PIN_ANT
+33
dBm
Transmit RF input power
PIN_TX
+15
dBm
Transmit RF input power, bypass mode
PIN_TX_BYP
+20
dBm
Operating case temperature (Note 2)
TC
–40
+85
°C
Storage temperature
TSTG
–55
+150
°C
Junction temperature
TJ
+150
°C
T/R port load VSWR in transmit mode
VSWR
10:1
–
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value.
Note 2: Nominal thermal resistance, junction to case, is 18 °C/W.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 4. SKY65364-11 Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Transmit frequency range
f
890
960
MHz
Receive frequency range
f
900
960
MHz
LNA supply voltage
VCC_RX
3.00
3.30
3.45
V
Digital supply voltage
VDD1
3.00
VCC_RX
3.45
V
VDD2
3.40
VCC_TX1/2/3
3.80
V
PA supply voltage
VCC_TX1/2/3
3.40
3.60
3.80
V
Digital input voltage, logic 1 (EN, TR, BYP)
VIH
1.6
VDD1
V
Digital input voltage, logic 0 (EN, TR, BYP)
VIL
0
0.7
V
Transmit output power control voltage
VPC
0
2.25
2.50
V
Receive RF input power (RX2)
PIN_RX2
–15
dBm
Transmit RF input power (TX)
PIN_TX
+10
+13
dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Table 5. SKY65364-11 DC Electrical Specifications (Note 1)
(VCC_RX = VDD1 = 3.0 V to 3.45 V, VCC_TX1/2/3 = VDD2 = 3.4 V to 3.8 V, TC = –40 °C to +85 °C, RBIAS = 0 Ω, No RF Input Power, Unless
Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
20
mA
Quiescent current, receive mode (Note 2)
IQ_RX
Quiescent current, receive low current mode
(Note 2) (Note 3)
IQ_RX_LC
Quiescent current, receive bypass mode
(Note 2)
IQ_BYP
34
76
μA
VDD1 quiescent current, transmit mode
IQ_VDD1
25
30
mA
VCC_TX1/2/3 quiescent current, transmit
mode
IQ_TX
TC = 25 °C,
VCC_TX1/2/3 = 3.6 V,
VCC_RX = 3.3 V
55
VCC_TX1/2/3 operating current, transmit
mode
IOP_TX
PIN = +10 dBm
730
VDD1 quiescent current, transmit bypass
mode (Note 3)
IDD1
VCC_TX1/2/3 quiescent current, transmit
bypass mode (Note 3)
RBIAS = 3.8 kΩ
5
mA
mA
880
mA
10
μA
IQ_TXB
0.030
μA
VCC_RX quiescent current, shutdown mode
(Note 3)
IQ_SD_RX
0.025
μA
VCC_TX1/2/3 quiescent current, shudown
mode (Note 3)
IQ_SD_TX
0.030
μA
Digital input current, logic 1 (Note 3)
IIH
33
μA
Digital input current, logic 0 (Note 3)
IIL
0
μA
Note 1: Performance is guaranteed only under the conditions listed in this Table. Modes are established as indicated in Table 2.
Note 2: Total current drawn from VCC_RX and VDD1 supplies.
Note 3: Not production tested.
Table 6. SKY65364-11 Electrical Specifications: Receive and Receive Bypass Mode (1 of 2) (Note 1)
(VCC_RX = VDD1 = 3.0 V to 3.45 V, VCC_TX1/2/3 = VDD2 = 3.4 V to 3.8 V, TC = –40 °C to +85 °C, f = 900 to 960 MHz, 50 Ω Source and
Load Impedance, CW Input, RBIAS = 0 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
13.5
16.5
Max
Units
Receive Mode: RX2 to Receive Output Path
Small signal gain
G
Noise Figure
NF
Noise Figure variation over temperature
NFTEMP
1 dB Input Compression Point
IP1dB
1 dB gain compression
3rd Order Input Intercept Point
IIP3
PIN = –30 dBm/tone,
200 kHz spacing
Input return loss
|S11|
8
dB
Output return loss
|S22|
8
dB
Reverse isolation
|S12|
Non-harmonic spurious (Note 2) (Note 3)
PSPUR
Transition time (Note 2)
t
TC = 25 °C,
VCC_RX = 3.3 V
1.7
dB
2.1
dB
±0.15
dB
–16.5
–11.5
dBm
–5.0
–1.7
dBm
16
22
VSWR 10:1, all phases
dB
–50
0.5
dBm
μs
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
5
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Table 6. SKY65364-11 Electrical Specifications: Receive and Receive Bypass Mode (2 of 2) (Note 1)
(VCC_RX = VDD1 = 3.0 V to 3.45 V, VCC_TX1/2/3 = VDD2 = 3.4 V to 3.8 V, TC = –40 °C to +85 °C, f = 900 to 960 MHz, 50 Ω Source and
Load Impedance, CW Input, RBIAS = 0 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Receive Low Current Mode (Note 2)
Small signal gain
G
RBIAS = 3.8 kΩ
15
dB
Noise Figure
NF
TC = 25 °C,
VCC_RX = 3.3 V,
RBIAS = 3.8 kΩ
1.7
dB
1 dB Input Compression Point
IP1dB
1 dB gain compression,
RBIAS = 3.8 kΩ
–23
dBm
3rd Order Input Intercept Point
IIP3
PIN = –30 dBm/tone,
200 kHz spacing,
RBIAS = 3.8 kΩ
–13.5
dBm
Input return loss
|S11|
RBIAS = 3.8 kΩ
8
dB
Output return loss
|S22|
RBIAS = 3.8 kΩ
8
dB
Non-harmonic spurious (Note 3)
PSPUR
VSWR 10:1, all phases,
RBIAS = 3.8 kΩ
Transition time
t
RBIAS = 3.8 kΩ
–50
dBm
μs
0.5
Receive Bypass Mode: RX2 to Receive Output Path
Insertion loss
IL
1 dB Input Compression Point
IP1dB
1 dB gain compression
3
3rd Order Input Intercept Point
IIP3
PIN = –30 dBm/tone,
200 kHz spacing
Input return loss
|S11|
8
Output return loss
|S22|
10
Transition time (Note 2)
t
+14.0
5
dB
+16.5
dBm
+30
dBm
dB
dB
μs
0.5
Receive and Receive Bypass Mode: ANT to RX1 Path
Insertion loss
IL
0.9
1.4
1 dB Input Compression Point (Note 2)
IP1dBANT
1 dB gain compression
+34
dBm
3rd Order Input Intercept Point (Note 2)
IIP3ANT
PIN = –10 dBm/tone,
200 kHz spacing
+50
dBm
Input return loss
|S11|
10
13
dB
Output return loss
|S22|
10
13
dB
Transition time (Note 2)
t
0.5
μs
Note 1: Performance is guaranteed only under the conditions listed in this Table. Modes are established as indicated in Table 2.
Note 2: Not production tested.
Note 3: Measurement performed with spectrum analyzer RBW = 100 kHz for frequencies < 1 GHz and RBW = 1 MHz for frequencies between 1 GHz and 10 GHz.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
dB
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Table 7. SKY65364-11 Electrical Specifications: Transmit Mode (Note 1)
(VCC_RX = VDD1 = 3.0 V to 3.45 V, VCC_TX1/2/3 = VDD2 = 3.4 V to 3.8 V, PIN = +10 dBm, VPC = 2.25 V, TC = –40 °C to +85 °C, f = 890 to
960 MHz, 50 Ω Source and Load Impedance, CW Input, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
+30.0
+30.5
Max
Units
TX to ANT Path
Output power (Note 2)
POUT
TC = 25 °C,
VCC_TX1/2/3 = 3.6 V
dBm
Output power variation over supply voltage
TC = 25 °C
±0.4
dB
Output power variation over temperature
VCC_TX1/2/3 = 3.6 V
±0.3
dB
50
dB
21.9
dB
Output power control
PCTL
VPC = 0 V to 2.25 V
(Note 3)
Small signal transmit PA gain
GTX
PRF input @ –30 dBm
40
Power-Added Efficiency (Note 5)
PAE
2nd harmonic
2fo
36
–50
dBc
3rd to 10th harmonic (Note 4)
3fo to 10fo
–50
dBc
Input return loss
|S11|
Output return loss
|S22|
Non-harmonic spurious (Note 5) (Note 6)
PSPUR
Power on time (Note 5)
t
0.5
Insertion loss
IL
2.7
1 dB Input Compression Point (Note 5)
IP1dB
+30
14
38
%
21
dB
6.5
dB
VSWR 10:1, all phases
–50
dBm
μs
TX to ANT Path, Transmit Bypass Mode
rd
3.3
dB
dBm
3 Order Input Intercept Point (Note 5)
IIP3
2nd harmonic
2fo
PIN = +12 dBm
–76
–40
dBc
3 harmonic
3fo
PIN = +12 dBm
–70
–40
dBc
Transmit bypass path rejection
R2FO
@ 2fo (1780 MHz to
1920 MHz)
@ 3fo (2670 MHz to
2880 MHz)
rd
R3FO
Input return loss
+40
dBm
27
39
dB
34
49
dB
|S11|
8
Output return loss
|S22|
10
Transition time (Note 5)
t
dB
dB
0.5
μs
ANT to RX1 Path
Isolation
|S21|
18.0
20.3
dB
|S21|
18
29
dB
ANT to RX1 Path, Transmit Bypass Mode
Isolation
Note 1: Performance is guaranteed only under the conditions listed in this Table. Modes are established as indicated in Table 2.
Note 2: Output power rated at the antenna output. PA output power is actually 1.5 dB higher or +32 dBm for a POUT of +30.5 dBm.
Note 3: Output power control is the difference between the output power at VPC = 2.25 V and VPC = 0 V.
Note 4: Only the 2nd to 5th harmonics have been production tested. The 6th to 10th harmonics are characterized only.
Note 5: Not production tested.
Note 6: Measurement performed with spectrum analyzer RBW = 100 kHz for frequencies < 1 GHz and RBW = 1 MHz for frequencies between 1 GHz and 10 GHz.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
7
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Typical Performance Characteristics
Figure 3. Receive Mode (RX2 to RX0) Small Signal Gain vs
Frequency Over Temperature
Figure 4. Receive Mode (RX2 to RX2) Noise Figure vs Frequency
Over Temperature
Figure 5. Receive Mode (RX2 to RX0) IIP3 vs Frequency
Over Temperature
Figure 6. Receive Bypass Mode (RX2 to RX0) Insertion Loss vs
Frequency Over Temperature
Figure 7. Receive Bypass Mode (RX2 to RX0) IP1dB vs Frequency
Over Temperature
Figure 8. Receive Bypass Mode (RX2 to RX0) IIP3 vs Frequency
Over Temperature
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Figure 9. Receive Bypass Mode (ANT to RX1) Insertion Loss vs
Frequency Over Temperature
Figure 10. Transmit Mode (TX to ANT) Output Power vs Frequency
Over Temperature
Figure 11. Transmit Bypass Mode (TX to ANT) Insertion Loss vs
Frequency Over Temperature
Figure 12. Transmit Bypass Mode (TX to ANT) 2nd Harmonic vs
Frequency Over Temperature
Figure 13. Transmit Bypass Mode (TX to ANT) 3rd Harmonic vs
Frequency Over Temperature
Figure 14. Transmit Bypass Path Rejection vs Frequency
Over Temperature
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
9
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Figure 15. Transmit Bypass Path Rejection vs Frequency
Over Temperature
Figure 16. Transmit Mode (ANT to RX1) Isolation vs Frequency
Over Temperature
Figure 17. Transmit Bypass Mode (ANT to RX1) Isolation vs
Frequency Over Temperature
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Evaluation Board Description
Package and Handling Information
The SKY65364-11 Evaluation Board is used to test the
performance of the SKY65364-11 T/R FEM. A typical application
schematic diagram is provided in Figure 18. An Evaluation Board
schematic diagram is provided in Figure 19. An assembly drawing
for the Evaluation Board is shown in Figure 20 and the layer is
provided in Figure 21.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
Package Dimensions
Package dimensions for the 28-pin MCM are shown in Figure 22,
and tape and reel dimensions are provided in Figure 23.
The SKY65364-11 is rated to Moisture Sensitivity Level 3 (MSL3)
at 260 °C. It can be used for lead or lead-free soldering. For
additional information, refer to Skyworks Application Note, PCB
Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Figure 18. SKY65364-11 Typical Application Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
11
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Figure 19. SKY65364-11 Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
P1
J5
J1
J4
J2
J3
S2873
Figure 20. SKY65364-11 Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
13
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Layer 1: Top – Metal
Layer 2: Ground
Layer 3: Ground
Layer 4: Solid Ground Plane
S2874
Figure 21. SKY65364-11 Evaluation Board Layer Detail
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
14
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Figure 22. SKY65364-11 28-Pin MCM Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
15
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Figure 23. SKY65364-11 28-Pin MCM Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
16
July 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201576B
DATA SHEET • SKY65364-11 T/R FRONT-END MODULE
Ordering Information
Model Name
SKY65364-11 T/R Front-End Module
Manufacturing Part Number
SKY65364-11
Evaluation Board Part Number
TW19-D900
Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201576B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 3, 2012
17