Data Sheets - Skyworks Solutions, Inc.

DATA SHEET
SKY66108-11: 2.4 GHz ZigBee®/Smart Energy Front-End
Module
Applications
 Smart meters
CPS
CTX
CSD
CRX
 In-home appliances
 Smart thermostats
Logic Control
Features
PA
 Integrated:
– PA with up to +16 dBm output power
– LNA with programmable bypass
– Transmit and receive switching function
VB_IN
TRXP
TRXN
ANT
Balun
LNA
 +2.7 dB FEM Rx NF
Y1854
 Differential Rx/Tx interface with integrated balun
Figure 1. SKY66108-11 Block Diagram
 Fast switch on/off time <800 ns
 2.0 V to 3.6 V supply operation
 Sleep mode current 0.05 μA typical
 QFN (20-pin, 3.0 mm x 3.0 mm x 0.55 mm) package
(MSL1 @ 260 °C per JEDEC J-STD-020)
GND
VCC2
GND
N/C
N/C
20
19
18
17
16
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
2
14
N/C
TRXP
3
13
ANT
TRXN
4
12
CSD
N/C
5
11
CTX
GND
CPS
N/C
CRX 10
VB_IN
9
N/C
8
15
7
1
6
The SKY66108-11 is a high-performance, fully integrated RF
Front-End Module (FEM) that is designed for ZigBee®/Smart
Energy applications.
The SKY66108-11 is designed for ease of use and maximum
flexibility, with integrated fully matched input balun, integrated
inter-stage matching and harmonic filter, and digital controls that
are compatible with 1.6 V to 3.6 V Complementary Metal Oxide
Semiconductor (CMOS) levels.
The RF blocks operate over a wide supply voltage range from
2.0 V to 3.6V, which allows the SKY66108-11 to be used in
battery-powered applications over a wide spectrum of the battery
discharge curve.
VCC1
VCC
Description
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
Y0770
Figure 2. SKY66108-11 Pinout—20-Pin QFN
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202969B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 16, 2015
1
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Table 1. SKY66108-11 Signal Descriptions
Pin
Name
1
VCC1
2
Description
Pin
Name
Description
Positive supply
12
CSD
Sleep mode control
VB_IN
Bias voltage input supply to the transceiver (see Figure 3)
13
ANT
Connect to 50 Ω antenna
3
TRXP
Input/output signal to the transceiver, 100 Ω differential
14
N/C
Not connected
4
TRXN
Input/output signal to the transceiver, 100 Ω differential
15
N/C
Not connected
5
N/C
Not connected
16
N/C
Not connected
6
VCC
Positive supply
17
N/C
Not connected
7
N/C
Not connected
18
GND
Connect to PCB ground
8
CPS
Bypass mode control, connect to RFIC or SoC GPIO
19
VCC2
Positive supply
9
GND
Connect to PCB the ground
20
GND
Connect to PCB ground
10
CRX
Receive function control
Paddle
GND
11
CTX
Transmit function control
Exposed die paddle; electrical and thermal ground; connect to
PCB ground
FEM
Optional Output Filter
2n7
SoIC
1 pF
1 pF
VB_IN
VDD_PA
1 kΩ each series resistor,
placed close to the SKY66108-11 pins.
CPS
CSD
CTX
Internal Lattice Balun
1.8 V
Differential source
or load impedance symbol
Input
Input
Decoupling capacitor
on chip
1.8 V
1.8 V VBIAS_IN
The balun at the FEM PA input (or LNA output) can also be used to inject a bias
operating point for the transceiver output stage (the shunt inductor provides a DC
path on the other side). The inductor also tunes out any parasitic capacitance.
If the SOIC transceiver does not require a DC bias, leave the VB_IN open.
Y1902
Figure 3. Injecting a Bias Operating Point for the Transceiver Output Stage
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
April 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202969B
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Electrical and Mechanical Specifications
The electrical specifications are provided in Tables 4 through 7.
The state of the SKY66108-11 is determined by the logic provided
in Table 8.
The absolute maximum ratings of the SKY66108-11 are provided
in Table 2. The recommended operating conditions are specified
in Table 3.
Table 2. SKY66108-11 Absolute Maximum Ratings
Parameter
Symbol
Supply voltage
VCC1, VCC2, VCC3
Control pin voltages
Minimum
Maximum
Units
–0.3
3.6
V
–0.3
3.6
V
125
C
Operating temperature
TA
–40
Storage temperature
TSTG
–40
125
C
Tx output power at the ANT port into 50 Ω load
POUT_TX_MAX
+16
dBm
Tx input power at the TR port
PIN_TX_MAX
+6
dBm
Rx input power at the ANT port
PIN_RX_MAX
+5
dBm
Thermal resistance
θJC
69
C/W
Electrostatic discharge:
ESD
1000
V
Human Body Model (HBM), Class 1C
Note:
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. Recommended Operating Conditions
Minimum
Typical
Maximum
Units
Ambient temperature
Parameter
TA
Symbol
–40
+25
+125
C
Supply voltage for transceiver core
VB_IN
1.6
3.6
V
Supply voltage on Vcc pins
VCC1, VCC2, VCC3
2.0
3.6
V
3.0
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202969B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 16, 2015
3
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Table 4. SKY66108-11 Electrical Specifications: DC (Note 1)
(VCC = VCC1 = VCC2 = 3 V, TA = +25 C, Measured on the Evaluation Board [De-embedded to the Device], Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Total supply current
ICC_ TX14
Tx mode POUT = +14 dBm
33
mA
Total supply current
ICC_ TX12
Tx mode POUT = +12 dBm
25
mA
Total supply current
ICC_ TX10
Tx mode POUT = +10 dBm
20
mA
Quiescent current
ICQ_ TX
No RF
6
mA
Total supply current
ICC_ RXHG
Rx Low Noise Amplifier (LNA) High Gain mode
5.5
mA
Total supply current
2.7
ICC_ RXLG
Rx LNA Low Gain mode
Total supply current
ICC_ RxBypass
Rx Bypass mode
Sleep supply current
ICC_ OFF
No RF
0.05
mA
10
μA
1.0
μA
Max
Units
V
Note 1: Performance is guaranteed only under the conditions listed in this table.
Table 5. SKY66108-11 Electrical Specifications: Logic Characteristics (Note 1)
(VCC = VCC1 = VCC2 = 3.0 V, TA = +25 C, Measured on the Evaluation Board [De-embedded to the Device],
Unless Otherwise Noted)
Parameter
Symbol
Logic input high voltage
Test Condition
Min
Typical
VBIHB
1.6
3.6
Logic input low voltage
VBILB
0
0.3
V
Logic input high current
IBIHB
1
μA
Logic input low current
IBILB
1
μA
Note 1: Performance is guaranteed only under the conditions listed in this table.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
April 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202969B
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Table 6. SKY66108-11 Electrical Specifications: AC Characteristics (Note 1)
(VCC = VCC1 = VCC2 = 3.0 V, TA = +25 C, Measured on the Evaluation Board [De-embedded to the Device],
All Unused Ports Terminated with 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Minimum
Typical
Maximum
Units
2483
MHz
Transmit (Tx)
Frequency range
fIN
2400
Output power at ANT port
POUT_Hi
2400 MHz to 2483 MHz, OEVM = 1% typical:
VCC = VCC1 = VCC2 = 3.6 V
VCC = VCC1 = VCC2 = 3.3 V
VCC = VCC1 = VCC2 = 3.0 V
VCC = VCC1 = VCC2 = 2.0 V
VCC = VCC1 = VCC2 = 1.8 V
Small signal gain high power mode
S21_Hi
2400 MHz to 2483 MHz
Small signal gain variation
ΔS21
2400 MHz to 2483 MHz
Gain variation across all 802.15.4 channels
1
dBp-p
Second and third harmonics
HD2, HD3
2400 MHz to 2483 MHz
IEEE 802.15.4 source
POUT = +14 dBm
Measured with the antenna match and filter
components per the SKY66108-11-EK1
evaluation board
–42
dBm/
MHz
Bluetooth® V 1.0 and BLE spectral mask
ACPR
ACPR @ ± 2 channels
ACPR @ ± 3 channels
tON
Turn on and off times
tOFF
+16.0
+15.0
+14.0
+11.0
+9.5
14
dB
STAB
CW, PIN = +0 dBm
0.1 GHz to 20.0 GHz
Load VSWR = 6:1
Ruggedness
RU
CW, PIN = +6 dBm, Load VSWR = 10:1
dB
dB
> –40
> –40
From 50% of the CTX edge to 90% of the final
RF output power.
From 50% of the CTX edge to 10% of the final
RF output power.
Stability
dBm
800
ns
All non-harmonically related outputs
<–35.0 dBm/MHz
No permanent damage
Receive (Rx)
Frequency range
fIN
Rx gain high-gain mode
Rx_gain_HG
2400 MHz to 2483 MHz
10.3
Rx gain low-gain mode
Rx_gain_LG
2400 MHz to 2483 MHz
5
Rx noise figure (NF) high-gain mode
NF_HG
2400 MHz to 2483 MHz
2.7
dB
Rx NF low-gain mode
NF_LG
2400 MHz to 2483 MHz
+3.8
dB
Input 1 dB compression point high-gain mode
IP1dB_HG
2400 MHz to 2483 MHz
–13
–8
dBm
Input 1 dB compression point low-gain mode
IP1dB_LG
2400 MHz to 2483 MHz
–3
+2
dBm
tON
From 50% of the CTX edge to 90% of the final
RF output power.
From 50% of the CTX edge to 10% of the final
RF output power.
Turn on and off times
tOFF
Gain in bypass mode
G_bp
Input 1 dB compression point in bypass mode
IP1dB
2400
2483
MHz
12.3
14.3
dB
7
9
dB
800
–3.5
+10
ns
dB
dBm
Note 1: Performance is guaranteed only under the conditions listed in this table.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202969B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 16, 2015
5
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Table 7. SE2438T Electrical Specifications: AC Characteristics, Antenna Switch (Note 1)
(VCC1 = VCC2 = VCC2 = 3 V, TA = +25 C, Measured on the Evaluation Board [De-embedded to the Device],
All Unused Ports Terminated with 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Min
Typical
Max
Units
Input return loss at ANT port, Rx mode
S11
–10
–5
dB
Output return loss at ANT port, Tx mode
S22
–10
–5
dB
Note 1: Performance is guaranteed only under the conditions listed in this table.
Table 8. SKY66108-11 Logic Controls (Notes 1 and 2)
(VCC = VCC1 = VCC2 = 3.0 V, TA = +25 C, Unless Otherwise Noted)
Mode
Description
CSD
CPS
CRX
CTX
Current Consumption
0
All off
0
0
0
0
Table 4
1
Standby
0
0
0
1
1.907 μA
2
Standby
0
0
1
0
1.907 μA
3
Standby
0
0
1
1
3.8 μA
4
Standby
0
1
0
0
1.907 μA
5
Standby
0
1
0
1
3.8 μA
6
Standby
0
1
1
0
3.8 μA
7
Standby
0
1
1
1
5.69 μA
8
Standby
1
0
0
0
1.907 μA
9
Tx bypass mode
1
0
0
1
Same as Rx Bypass mode (Table 4)
10
Rx bypass mode
1
0
1
0
Table 4
11
Regulator enabled
1
0
1
1
210 μA
12
Rx LNA (LG)
1
1
0
0
Table 4
13
TX high power mode
1
1
0
1
Table 4
14
Rx LNA(HG)
1
1
1
0
Table 4
15
Standby
1
1
1
1
7.6 μA
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Modes 1 through 8, 11, and 15 are for internal use only.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
April 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202969B
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Evaluation Board Description
Package Dimensions
The SKY66108-11 Evaluation Board is used to test the
performance of the SKY66108-11 FEM. The board is optimized for
evaluation, experimentation, and investigation with an 802.15.4
signal source. The design and layout can be quickly and easily
transferred into a production design.
The PCB layout footprint for the SKY66108-11 is provided in
Figure 7. Typical part markings for the SKY66108-11 are shown
in Figure 8. Package dimensions are shown in Figure 9, and tape
and reel dimensions are provided in Figure 10.
An Evaluation Board schematic diagram is provided in Figure 4.
A reference design schematic is provided in Figure 5. Table 9
describes the pins on the power and control I/O header (J3).
Table 10 provides the Bill of Materials (BOM) list for Evaluation
Board components. A photograph of the Evaluation Board is
shown in Figure 6.
Package and Handling Information
Evaluation Board Setup Procedure
The SKY66108-11 package is Pb free, RoHS compliant, halogen
free, and rated to Moisture Sensitivity Level 1 (MSL1). For
additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
1. Connect (J1, J2) to 50 Ω instruments. Terminate all unused
ports (if applicable) with 50 Ω.
2. Connect the supply ground to pin 19 or 20 of J3.
3. Connect 3.0 V to VCC, VCC1, and VCC2 of J3.
4. Connect 1.8 V to Pin 8 of J3.
5. Monitor the 2.5 GHz amplifier transmit performance by
applying an RF signal to J2 and monitoring the output power
on J1 (ANT).
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
6. Monitor the 2.5 GHz amplifier receive performance by applying
an RF signal to connector J1 (ANT) and monitoring the output
signal on connector J2.
CAUTION: Care should be taken not to overdrive the amplifier by
applying too much RF on the input to the device. A
suitable starting input power would be –20 dBm.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202969B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 16, 2015
7
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
VCC
VCC
VCC
J3
C6
10 pF
L1
3.6 nH
C2
100 nF
×
N/C
14
ANT
13
SKY66108-11
U1
N/C
CTX
6
VCC
C4
100 nF
C8
10 pF
7
8
9
12
11
J1
SMA
L2
2.7 nH
CSD
C12
1 pF
C11
1 pF
R3
100K
CRX
CSD
GND
TRXN
VCC
C7
10 pF
N/C
GND
VCC2
VB_IN
CPS
×
5
15
TRXP
CTX
CSD
×
N/C
N/C
4
BAL_PT
5
4
BAL_PT
3
C1
2.2 μF
16
VCC1
3
6
N/C
GND
RF_GND
UN_BAL
2
1
2
17
×
J4
SMA
VB
18
VB
CPS
CRX
×
1
HHM1520
U2
19
Pad
C5
10 pF
×
20
GND
N/C
21
VCC
2
4
6
8
10
12
14
16
18
20
1
3
5
7
9
11
13
15
17
19
C3
100 nF
CTX
10
CRX
×
R1
100K
R4
100K
CPS
R2
100K
PCB Recommendations:
Metal Layer 1 = RF traces + control lines. Core thickness between top RF layer and ground plane is critical.
Metal Layer 2 = Solid ground plane. No traces routing.
Metal Layer 3 and 4 = Control lines + VCC traces (no VCC plane).
Pour copper on each layer connected to the ground plane. Use VCC traces in a star distribution pattern.
Y1903
Figure 4. SKY66108-11 Evaluation Board Schematic
Table 9. SKY66108-11 Power and Analog I/O Header: J3, 10x2
Pin Number
Evaluation Board Label
Description
Recommended setting
14, 19, 20
GND
Ground
General purpose grounds
1, 3, 5, 6, 7, 9, 11, 13, 15, 17
VCC
Supply voltage
General purpose VCC provided as the main power supply
4
VCC1
Supply voltage
General purpose VCC provided as the main power supply
2
VCC2
Supply voltage
General purpose VCC provided as the main power supply
Output bias to transceiver
8
VB
Bias
16
CTX
Control
10
CPS
Control
18
CSD
Control
12
CRX
Control
See Table 8
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
April 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202969B
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
VCC
C1
2.2 μF
C3
100 nF
C6
10 pF
L1
3.6 nH
C2
100 nF
×
5
VB_IN
GND
14
TRXP
ANT
13
TRXN
CSD
N/C
CTX
VCC
TRXN
6
VCC
C4
100 nF
C8
10 pF
7
×
8
9
12
CSD
11
CTX
L2
2.7 nH
C11
1 pF
ANT
C12
1 pF
CRX
×
4
15
GND
See Note 1
N/C
CPS
3
VCC1
N/C
TRXP
16
N/C
Pad
2
17
×
VB
18
GND
VCC2
19
×
1
L3
DNI
20
GND
N/C
21
C5
10 pF
×
10
CRX
CPS
Note 1:
There are two ways that the SKY66108-11 input can be interface single ended:
1. One input can be terminated with 50 Ω to ground, the other input impedance is 50 Ω.
2. One input can be shorted to ground, the other input impedance is 100 Ω.
Y1904
Figure 5. SKY66108-11 Evaluation Board Reference Design Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202969B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 16, 2015
9
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Table 10. SKY66108-11 Evaluation Board Bill of Materials
Description
Value
Manufacturer
Mfr Part Number
Package
Description
C1
2.2 μF
Murata
GRM21BR71A225KA01L
0805
Capacitor ceramic 2.2 μF 10 V
10% X7R 0805
L2
2.7 nH
Murata
LQG15HN2N7S02D
0402
High frequency multilayer
L1
3.6 nH
Murata
LQG15HN3N6S02D
0402
High frequency multilayer
J3
10 x 2
Samtec
TSW-110-07-G-D
100 mil
100 mil header
U2
HHM1520
TDK
HHM1520
2.00MMX1.25
Multilayer chip baluns 2.4 GHz
U1
SKY66108-11
Skyworks
SKY66108-11
QFN3X3-20
2.4 GHz 14 dBm FEIC
C11, C12
1 pF
Murata
GRM1555C1H1R0CZ01
0402
Multilayer ceramic
J1, J2
SMA
Johnson Components
142-0701-851
End Launch
SMA end launch straight jack receptacle—
tab contact
C2, C3, C4
100 nF
Murata
GRM155R71C104KA88D
0402
Monolithic ceramic
C5, C6, C7, C8
10 pF
Murata
GRM1555C1H100JZ01
0402
Multilayer ceramic
R1, R2, R3, R4
100 kΩ
Panasonic
ERJ2GEJ104
0402
Thick film chip resistor
Y0771
Figure 6. SKY66108-11 Evaluation Board Photograph
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
April 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202969B
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Package
Outline
3.20
20x 0.20
20
19
18
17
20
16
0.57 Typ
3.20
20x 0.20
18
17
16
20
20x 0.55
19x 0.45
3.20
19
3.30
20x 0.30
19
18
17
16
20x 0.45
1
15
1
15
1
15
2
14
2
14
2
14
3
13
3
13
3
13
4
12
4
12
4
12
5
11
5
11
5
11
6
7
8
0.400 Typ
9
10
1.80
0.10
1.60
3.30
9x Ø0.254
6
7
8
9
6
10
1.60
1.80
Board Metal and Via Pattern
(Note 4)
7
8
9
0.625 Typ
10
0.400 Typ
0.400 Typ
0.57 Typ
3.30
0.625 Typ
0.10
Solder Mask Pattern
(Note 6)
Stencil Pattern
(Note 5)
Notes:
61% solder coverage
on center pad
1.
2.
3.
4.
All dimensions are in millimeters.
Dimensions and tolerances according to ASME Y14.5M-1994.
Unless specified, dimensions are symmetrical about center lines.
Via hole recommendations: 30 to 35 µm Cu via wall plating (minimum),
via holes should be tented with solder mask on the back side and filled with solder.
5. Stencil recommendations: 0.125 mm stencil thickness, laser cut
apertures, trapezoidal walls and rounded corners offer better paste release.
6. Solder mask recommendations: contact board fabricator for recommended
solder mask offset and tolerance.
Y0774
Figure 7. PCB Layout Footprint
Pin 1 Designator
e4
Part Number
Lot Code
SKY
66108
XXXX
Figure 8. SKY66108-11 Part Markings
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202969B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 16, 2015
11
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
3.000 ±0.050
B
19
18
17
0.10 M C A B
0.152 Ref
See Note 3
20
1.700 ±0.050
0.550 ±0.050
A
0.300 x 45°
16
16
17
18
19
20
1
15
15
2
14
14
3
13
4
12
12
4
5
11
11
5
1
0.400
3.000 ±0.050
13
1.700 ±0.050
2
R0.075
Typ
3
20 X 0.200 ±0.050
0.07 M C A B
0.05 M C
0.10 M C A B
2X
6
7
8
9
10
2X
Top View
0.10 C
10
0.10 C
0 – 0.050
C
0.250 Min
8
7
6
0.200 Ref
20 X 0.350 ±0.050
Seating Plane
See Note 4
Bottom View
Notes:
1.
2.
3.
4.
9
All dimensions are in millimeters.
Dimensions and tolerances according to ASME Y14.5--1994.
Terminal 1 identification mark located within this area.
Unilateral coplanarity zone applies to the exposed heat sink ground pad as well as the terminals.
Figure 9. SKY66108-11 Package Dimensions
Figure 10. SKY66108-11 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
April 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202969B
Y0773
DATA SHEET • SKY66108-11: 2.4 GHz SMART ENERGY/ZIGBEE FRONT-END MODULE
Ordering Information
Model Name
SKY66108-11: 2.4 GHz Smart Energy/ZigBee Front-End Module
Manufacturing Part Number
SKY66108-11
Evaluation Board Part Number
SKY66108-11-EK1
Copyright © 2012-2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202969B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • April 16, 2015
13