SE5007BT - Skyworks Solutions, Inc.

DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Applications
Product Description


The SE5007BT is a 5GHz front end module offering
high linear power for wireless LAN applications. It
incorporates a power detector for control of the output
power.
5 GHz WLAN (IEEE802.11a/g/n)
Access Points, PCMCIA, PC cards, Handhelds
Features








5GHz Front End Module with PA, LNA and T/R
Switch
Integrated power amplifier enable pin (VEN)
Buffered, temperature compensated power
detector
High and Low-Linearity mode
3% EVM, @17dBm, 64 QAM, 54 Mbps
30 dB Typical Gain
Lead Free and RoHS compliant, halogen free
package
16 pin 3 mm x 3 mm x 0.6 mm QFN, MSL1
The SE5007BT offers a high level of integration for a
simplified design, providing quicker time to market
and higher application board production yield. The
device integrates inter-stage match, a temperature
compensated, load insensitive power detector with
20dB of dynamic range, a 3.8GHz notch filter, a T/R
switch and an Rx LNA.
For wireless LAN applications, the device meets the
requirements
of
IEEE802.11a
and
delivers
approximately 17dBm of linear output power. It also
features a low linearity mode control to reduce current
consumption at low power modes.
The SE5007BT integrates the reference voltage
generator, allowing for a true 1.8V CMOS compatible
digital EN (enable) function to turn the power amplifier
on and off.
Ordering Information
Part Number
Package
Remark
SE5007BT
SE5007BT-R
SE5007BTEK1
16 Pin QFN
16 Pin QFN
Evaluation Kit
Samples
Tape and Reel
Standard
Functional Block Diagram
VCC1,2
EN
TXIN
VPD
H/L Lin
C0
C1
Bias, Enable, Detector Circuits
Match
Match &
Filter
ANT
RX
TXIN and ANT are DC Blocked. However external blocking cap is recommended for RX output.
Figure 1: Functional Block Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
1
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Pin Out Diagram
Figure 2: SE5007BT Pin-Out Diagram
Pin Out Description
Pin
No.
Name
Pin
No.
Name
1
EN
PA Enable
9
VDD
LNA Supply Voltage (3.3V+/-10%
only)
2
GND
Ground
10
GND
Ground
3
RX
5GHz LNA Output Signal
11
ANT
5GHz Antenna output
4
GND
Ground
12
GND
Ground
5
TXIN
5GHz TX RF Input Signal
13
DET
Power Detector Output
6
GND
Ground
14
H/L Lin
High-Low linearity Control
7
C0
Switch Control Logic 1
15
VCC1
Power Stage Supply Voltage
8
C1
Switch Control Logic 2
16
VCC2
Bias, Driver Stage Supply Voltage
Description
Description
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
2
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Absolute Maximum Ratings
These are stress ratings only. Exposure to stresses beyond these maximum ratings for a long period of time may
cause permanent damage to, or affect the reliability of the device. Avoid operating the device outside the
recommended operating conditions defined below. This device is ESD sensitive. Handling and assembly of this
device should be at ESD protected workstations.
Symbol
VCC1
VDD, VCC2
EN
Definition
Min.
Max.
Unit
Supply Voltage on pin 15 (VCC1)
-0.3
4.8
V
Supply Voltage on pins 9, 16 (VDD, VCC2)
-0.3
3.6
V
DC input on Enable
-0.3
3.6
V
-
12
dBm
-40
150
°C
Antenna Pin
-
1000
All Other Pins
-
350
Min.
Max.
Unit
Supply Voltage on pin 15 (VCC1)
3.0
4.5
V
Supply Voltage on pins 9, 16 (VDD, VCC2)
3.0
3.6
V
Ambient Temperature
-40
85
°C
TXIN
RF Input Power, RFout into 50Ω match
TSTG
Storage Temperature Range
ESD HBM
JEDEC JESD22-A114
all pins
V
Recommended Operating Conditions
Symbol
VCC1
VDD, VCC2
TA
Parameter
Control Logic Characteristics
Conditions: VCC1 = VCC2 = VDD = VPAON = VEN = 3.3 V, TA = 25 °C, as measured on Skyworks Solutions’ SE5007TEV1 evaluation board, unless otherwise noted.
Symbol
Parameter
Supply Current,
Transmit Mode
ICC-802.11a
Supply Current,
Receive Mode
IOFF
Supply Current
VENH
Logic High Voltage
Conditions
Min.
Typ.
Max.
POUT = 17 dBm, 54 Mbps, 64 QAM,
H/L Lin = 3.3V (High Linearity Mode)
-
195
-
POUT = 13 dBm, 54 Mbps, 64 QAM,
H/L Lin = 0V (Low Linearity Mode)
-
140
-
POUT = 5 dBm, 54 Mbps, 64 QAM,
H/L Lin = 0V (Low Linearity Mode)
-
105
-
mA
POUT = 19 dBm, 54 Mbps, 64 QAM,
H/L Lin = 3.3V, VCC1 = 4.0V
220
VEN = C0 = 0V; C1 = 3.3V
15
VEN = C0 = C1 = 0V
VEN = 0 V, No RF, C0=C1=0 V
Measured on VCC, VDD pins
-
Unit
0.02
-
20
50
μA
1.6
-
Vcc
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
3
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Symbol
Parameter
Conditions
Min.
Typ.
Max.
Unit
VENL
Logic Low Voltage
-
-0.3
-
0.3
V
IENH
Input Current Logic
High Voltage
-
-
330
400
μA
IENL
Input Current Logic
Low Voltage
-
-
<1
-
μA
Switch Logic Characteristics
Conditions: VCC = VDD VEN = 3.3 V, TA = 25 °C, as measured on Skyworks Solutions’ SE5007BT-EK1 evaluation
board, all unused ports terminated with 50 ohms, unless otherwise noted.
Symbol
Parameter
Conditions
High State = VCTL_ON VCTL_OFF
Low State = VCTL_OFF VCTL_OFF
Low Loss Switch
Control Voltage
High Loss Switch
Control Voltage
Control Input
Capacitance
Control Line Current
ON
OFF
CCTL
ICTL
VCTL = VCTL_ON
Min.
Typ.
Max.
Unit
2.8
-
3.6
V
0
-
0.3
V
-
-
100
pF
-
2
10
uA
Switch Control Logic Table
C0
C1
EN
Hi/L Lin
ANT
ON
OFF
ON
OFF
TX Low Linearity
ON
OFF
ON
ON
TX High Linearity
OFF
OFF
OFF
D/C
Rx Bypass
OFF
ON
OFF
D/C
Rx LNA ON
ON
ON
Un-supported state
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
4
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
AC Electrical Characteristics
Transmit Characteristics
Conditions: VCC1 = VCC2 = VDD = VEN = C0 = H/L Lin = 3.3V, C1 = 0V, TA = 25 °C, as measured on Skyworks
Solutions’ SE5007T-EV1 evaluation board, unless otherwise noted
Symbol
fL-U
Parameter
Conditions
Min.
Typ.
Max.
Unit
-
4.90
-
5.85
GHz
EVM = 3%
-
17
-
EVM = 2%
-
15
-
EVM = 3%
-
19
-
MCS0, HT20, mask compliant
-
21
-
MCS0, HT40, mask compliant
-
20
-
Frequency Range
Output Power,
High Linearity Mode
H/L Lin = 3.3V
OFDM
POUT
802.11a,
64 QAM
VCC1 = 4.0V,
3% EVM
dBm
Output Power,
Low Linearity Mode
H/L Lin = 0V
OFDM
802.11a, 64 QAM, EVM = 3%
-
13
-
MCS0, HT20, mask compliant
-
17
-
MCS0, HT40, mask compliant
-
16
-
P1dB
Output 1dB
compression point
No modulation
-
24
-
dBm
S11
Input Return Loss
PIN = -25 dBm
-
14
-
dB
Small Signal Gain,
PIN = -25dBm
High Linearity Mode
28
31
-
dB
S21
Low Linearity Mode
26
30
-
Gain variation over single
40MHz channel
-
-
0.5
Gain Variation over band
-1.5
-
1.5
-
-
15
-
-50
-42
-
-50
-42
-
0.5
-
ΔS21
S21_3.8
Small Signal Gain
Variation
Out of Band Gain
Gain at 3.8GHz
Harmonic
POUT = 17 dBm, OFDM
2f
3f
tr , tf
Rise and Fall Time
-
dB
dBm/MHz
Stability
POUT = 17 dBm, 54 Mbps, 64
QAM, VSWR = 6:1, all phases
Ruggedness
Tolerance to output
load mismatching
Constant PIN equal to POUT = 17
dBm at 50ohms, 54 Mbps, 64
QAM, VSWR = 6:1, all phases
No damage
Robust
Robustness to input
power
PIN = 12dBm, CW, VSWR = 6:1,
all phases
No damage
STAB
dB
us
All non-harmonically related outputs less
than -50 dBc/100 kHz
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
5
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Receive Characteristics
Conditions: VCC = C1 = VDD= 3.3V, VEN = C0 = 0V, TA = 25 °C, as measured on Skyworks Solutions’ SE5007BTEK1 evaluation board, all unused ports terminated with 50 ohms, unless otherwise noted.
Symbol
FOUT
Parameter
Condition
Min.
Typ.
-
4.9
-
5.85
-
-5
-
Frequency Range
Max.
RXRL
RxIP1DB
Rx_2.4int
Ton/off
GHz
Insertion Loss
Bypass Mode: C0 = C1 = 0V
RX Gain
High Gain Mode
11
12
-
Noise Figure
High Gain Mode
-
2.5
-
Input Return Loss
At the Antenna port
-
12
-
Output Return
Loss
At RX RF output
-
8
-
Measured at ANT Port; High Gain
Mode
-
-5
-
LNA Bypass Mode
-
10
-
Max 2.4Ghz
interferer
Amplitude
1 dB degradation of IP1DB
-
-10
-7
dBm
T/R on/off
switching speed
C0, C1 (50%) to RF output (10% or
90%)
-
300
-
nSec
dB
RX
NF
Unit
Input P1DB
dB
dB
dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
6
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Power Detector Characteristics
Conditions: VCC = VEN =C0= VDD = 3.3V, C1 = 0V, f = 5.4 GHz, TA = 25 °C, as measured on Skyworks Solutions’
SE5007BT-EV1 evaluation board, unless otherwise noted
Symbol
PDR
Parameter
POUT detect range
Conditions
Min.
Typ.
Max.
Unit
-
0
-
P1dB
dBm
VDET22
Detector voltage
POUT = 22 dBm
0.7
-
0.9
V
VDET16
Detector voltage
POUT = 16 dBm
0.50
-
0.60
V
VDET2
Detector voltage
POUT = 2 dBm
0.25
-
0.35
V
PDZOUT
Output Impedance
-
5
-
KΩ
-
Power Detector Performance over Frequency
Figure 3: SE5007BT Power Detector Characteristic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
7
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Package Diagram
This package is Pb free and RoHS compliant. The product is rated MSL1.
16
15
14
13
13
14
15
16
1
12
12
1
2
11
11
2
3
10
10
3
4
9
9
4
5
6
7
8
8
7
6
5
TOP SIDE
BOTTOM SIDE
Figure 4: SE5007BT Package Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
8
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Recommended Land and Solder Patterns
Figure 5: SE5007BT Recommended Land and Solder Pattern
Package Handling Information
Because of its sensitivity to moisture absorption, instructions on the shipping container label must be followed
regarding exposure to moisture after the container seal is broken, otherwise, problems related to moisture absorption
may occur when the part is subjected to high temperature during solder assembly. The SE5007BT is capable of
withstanding a Pb free solder reflow. Care must be taken when attaching this product, whether it is done manually or
in a production solder reflow environment. If the part is manually attached, precaution should be taken to insure that
the device is not subjected to temperatures above its rated peak temperature for an extended period of time. For
details on both attachment techniques, precautions, and handling procedures recommended, please refer to:
 “Quad Flat No-Lead Module Solder Reflow & Rework Information”, Document Number QAD-00045
 “Handling, Packing, Shipping and Use of Moisture Sensitive QFN”, Document Number QAD-00044
Caution! Class 1A ESD sensitive device
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
9
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Branding Information
SiGe
5007B
Lot Code
Figure 6: SE5007BT Branding
Tape and Reel Information
Parameter
Devices Per Reel
Reel Diameter
Tape Width
Value
3000
13 inches
12 millimeters
Figure 7: SE5007BT-R Tape and Reel Information
Document Change History
Revision
Date
Notes
1.0
Nov 03, 2010
Created
1.1
Nov 22, 2010
Updated Supply voltage specs
1.2
Dec 20, 2010
Corrected RX Conditions in Control Logic table
1.3
Jan 03, 2011
Updated recommended storage temperature
1.4
Feb 8, 2011
Added 4V operation, Mask Performance,
Added reference to blocked RF ports on the block diagram
1.5
Apr 25, 2011
Update VENH (min) from 2.8V to 1.6V
Corrected product description – removed reference to Balun
1.6
Apr 11, 2012
Updated with Skyworks logo and disclaimer statement
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
10
DATA SHEET
SE5007BT: 5 GHz Front-End Module with Power Detector
Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein,
are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or
omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time,
without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other
difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials,
products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in
Skyworks Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE,
INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL
SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR
OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT,
INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE
MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to
personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to
fully indemnify Skyworks for any damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or
operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks.
Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated
published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries.
Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions,
posted at www.skyworksinc.com, are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012
11