DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Applications Product Description The SE5007BT is a 5GHz front end module offering high linear power for wireless LAN applications. It incorporates a power detector for control of the output power. 5 GHz WLAN (IEEE802.11a/g/n) Access Points, PCMCIA, PC cards, Handhelds Features 5GHz Front End Module with PA, LNA and T/R Switch Integrated power amplifier enable pin (VEN) Buffered, temperature compensated power detector High and Low-Linearity mode 3% EVM, @17dBm, 64 QAM, 54 Mbps 30 dB Typical Gain Lead Free and RoHS compliant, halogen free package 16 pin 3 mm x 3 mm x 0.6 mm QFN, MSL1 The SE5007BT offers a high level of integration for a simplified design, providing quicker time to market and higher application board production yield. The device integrates inter-stage match, a temperature compensated, load insensitive power detector with 20dB of dynamic range, a 3.8GHz notch filter, a T/R switch and an Rx LNA. For wireless LAN applications, the device meets the requirements of IEEE802.11a and delivers approximately 17dBm of linear output power. It also features a low linearity mode control to reduce current consumption at low power modes. The SE5007BT integrates the reference voltage generator, allowing for a true 1.8V CMOS compatible digital EN (enable) function to turn the power amplifier on and off. Ordering Information Part Number Package Remark SE5007BT SE5007BT-R SE5007BTEK1 16 Pin QFN 16 Pin QFN Evaluation Kit Samples Tape and Reel Standard Functional Block Diagram VCC1,2 EN TXIN VPD H/L Lin C0 C1 Bias, Enable, Detector Circuits Match Match & Filter ANT RX TXIN and ANT are DC Blocked. However external blocking cap is recommended for RX output. Figure 1: Functional Block Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 1 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Pin Out Diagram Figure 2: SE5007BT Pin-Out Diagram Pin Out Description Pin No. Name Pin No. Name 1 EN PA Enable 9 VDD LNA Supply Voltage (3.3V+/-10% only) 2 GND Ground 10 GND Ground 3 RX 5GHz LNA Output Signal 11 ANT 5GHz Antenna output 4 GND Ground 12 GND Ground 5 TXIN 5GHz TX RF Input Signal 13 DET Power Detector Output 6 GND Ground 14 H/L Lin High-Low linearity Control 7 C0 Switch Control Logic 1 15 VCC1 Power Stage Supply Voltage 8 C1 Switch Control Logic 2 16 VCC2 Bias, Driver Stage Supply Voltage Description Description Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 2 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Absolute Maximum Ratings These are stress ratings only. Exposure to stresses beyond these maximum ratings for a long period of time may cause permanent damage to, or affect the reliability of the device. Avoid operating the device outside the recommended operating conditions defined below. This device is ESD sensitive. Handling and assembly of this device should be at ESD protected workstations. Symbol VCC1 VDD, VCC2 EN Definition Min. Max. Unit Supply Voltage on pin 15 (VCC1) -0.3 4.8 V Supply Voltage on pins 9, 16 (VDD, VCC2) -0.3 3.6 V DC input on Enable -0.3 3.6 V - 12 dBm -40 150 °C Antenna Pin - 1000 All Other Pins - 350 Min. Max. Unit Supply Voltage on pin 15 (VCC1) 3.0 4.5 V Supply Voltage on pins 9, 16 (VDD, VCC2) 3.0 3.6 V Ambient Temperature -40 85 °C TXIN RF Input Power, RFout into 50Ω match TSTG Storage Temperature Range ESD HBM JEDEC JESD22-A114 all pins V Recommended Operating Conditions Symbol VCC1 VDD, VCC2 TA Parameter Control Logic Characteristics Conditions: VCC1 = VCC2 = VDD = VPAON = VEN = 3.3 V, TA = 25 °C, as measured on Skyworks Solutions’ SE5007TEV1 evaluation board, unless otherwise noted. Symbol Parameter Supply Current, Transmit Mode ICC-802.11a Supply Current, Receive Mode IOFF Supply Current VENH Logic High Voltage Conditions Min. Typ. Max. POUT = 17 dBm, 54 Mbps, 64 QAM, H/L Lin = 3.3V (High Linearity Mode) - 195 - POUT = 13 dBm, 54 Mbps, 64 QAM, H/L Lin = 0V (Low Linearity Mode) - 140 - POUT = 5 dBm, 54 Mbps, 64 QAM, H/L Lin = 0V (Low Linearity Mode) - 105 - mA POUT = 19 dBm, 54 Mbps, 64 QAM, H/L Lin = 3.3V, VCC1 = 4.0V 220 VEN = C0 = 0V; C1 = 3.3V 15 VEN = C0 = C1 = 0V VEN = 0 V, No RF, C0=C1=0 V Measured on VCC, VDD pins - Unit 0.02 - 20 50 μA 1.6 - Vcc V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 3 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Symbol Parameter Conditions Min. Typ. Max. Unit VENL Logic Low Voltage - -0.3 - 0.3 V IENH Input Current Logic High Voltage - - 330 400 μA IENL Input Current Logic Low Voltage - - <1 - μA Switch Logic Characteristics Conditions: VCC = VDD VEN = 3.3 V, TA = 25 °C, as measured on Skyworks Solutions’ SE5007BT-EK1 evaluation board, all unused ports terminated with 50 ohms, unless otherwise noted. Symbol Parameter Conditions High State = VCTL_ON VCTL_OFF Low State = VCTL_OFF VCTL_OFF Low Loss Switch Control Voltage High Loss Switch Control Voltage Control Input Capacitance Control Line Current ON OFF CCTL ICTL VCTL = VCTL_ON Min. Typ. Max. Unit 2.8 - 3.6 V 0 - 0.3 V - - 100 pF - 2 10 uA Switch Control Logic Table C0 C1 EN Hi/L Lin ANT ON OFF ON OFF TX Low Linearity ON OFF ON ON TX High Linearity OFF OFF OFF D/C Rx Bypass OFF ON OFF D/C Rx LNA ON ON ON Un-supported state Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 4 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector AC Electrical Characteristics Transmit Characteristics Conditions: VCC1 = VCC2 = VDD = VEN = C0 = H/L Lin = 3.3V, C1 = 0V, TA = 25 °C, as measured on Skyworks Solutions’ SE5007T-EV1 evaluation board, unless otherwise noted Symbol fL-U Parameter Conditions Min. Typ. Max. Unit - 4.90 - 5.85 GHz EVM = 3% - 17 - EVM = 2% - 15 - EVM = 3% - 19 - MCS0, HT20, mask compliant - 21 - MCS0, HT40, mask compliant - 20 - Frequency Range Output Power, High Linearity Mode H/L Lin = 3.3V OFDM POUT 802.11a, 64 QAM VCC1 = 4.0V, 3% EVM dBm Output Power, Low Linearity Mode H/L Lin = 0V OFDM 802.11a, 64 QAM, EVM = 3% - 13 - MCS0, HT20, mask compliant - 17 - MCS0, HT40, mask compliant - 16 - P1dB Output 1dB compression point No modulation - 24 - dBm S11 Input Return Loss PIN = -25 dBm - 14 - dB Small Signal Gain, PIN = -25dBm High Linearity Mode 28 31 - dB S21 Low Linearity Mode 26 30 - Gain variation over single 40MHz channel - - 0.5 Gain Variation over band -1.5 - 1.5 - - 15 - -50 -42 - -50 -42 - 0.5 - ΔS21 S21_3.8 Small Signal Gain Variation Out of Band Gain Gain at 3.8GHz Harmonic POUT = 17 dBm, OFDM 2f 3f tr , tf Rise and Fall Time - dB dBm/MHz Stability POUT = 17 dBm, 54 Mbps, 64 QAM, VSWR = 6:1, all phases Ruggedness Tolerance to output load mismatching Constant PIN equal to POUT = 17 dBm at 50ohms, 54 Mbps, 64 QAM, VSWR = 6:1, all phases No damage Robust Robustness to input power PIN = 12dBm, CW, VSWR = 6:1, all phases No damage STAB dB us All non-harmonically related outputs less than -50 dBc/100 kHz Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 5 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Receive Characteristics Conditions: VCC = C1 = VDD= 3.3V, VEN = C0 = 0V, TA = 25 °C, as measured on Skyworks Solutions’ SE5007BTEK1 evaluation board, all unused ports terminated with 50 ohms, unless otherwise noted. Symbol FOUT Parameter Condition Min. Typ. - 4.9 - 5.85 - -5 - Frequency Range Max. RXRL RxIP1DB Rx_2.4int Ton/off GHz Insertion Loss Bypass Mode: C0 = C1 = 0V RX Gain High Gain Mode 11 12 - Noise Figure High Gain Mode - 2.5 - Input Return Loss At the Antenna port - 12 - Output Return Loss At RX RF output - 8 - Measured at ANT Port; High Gain Mode - -5 - LNA Bypass Mode - 10 - Max 2.4Ghz interferer Amplitude 1 dB degradation of IP1DB - -10 -7 dBm T/R on/off switching speed C0, C1 (50%) to RF output (10% or 90%) - 300 - nSec dB RX NF Unit Input P1DB dB dB dBm Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 6 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Power Detector Characteristics Conditions: VCC = VEN =C0= VDD = 3.3V, C1 = 0V, f = 5.4 GHz, TA = 25 °C, as measured on Skyworks Solutions’ SE5007BT-EV1 evaluation board, unless otherwise noted Symbol PDR Parameter POUT detect range Conditions Min. Typ. Max. Unit - 0 - P1dB dBm VDET22 Detector voltage POUT = 22 dBm 0.7 - 0.9 V VDET16 Detector voltage POUT = 16 dBm 0.50 - 0.60 V VDET2 Detector voltage POUT = 2 dBm 0.25 - 0.35 V PDZOUT Output Impedance - 5 - KΩ - Power Detector Performance over Frequency Figure 3: SE5007BT Power Detector Characteristic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 7 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Package Diagram This package is Pb free and RoHS compliant. The product is rated MSL1. 16 15 14 13 13 14 15 16 1 12 12 1 2 11 11 2 3 10 10 3 4 9 9 4 5 6 7 8 8 7 6 5 TOP SIDE BOTTOM SIDE Figure 4: SE5007BT Package Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 8 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Recommended Land and Solder Patterns Figure 5: SE5007BT Recommended Land and Solder Pattern Package Handling Information Because of its sensitivity to moisture absorption, instructions on the shipping container label must be followed regarding exposure to moisture after the container seal is broken, otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. The SE5007BT is capable of withstanding a Pb free solder reflow. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. If the part is manually attached, precaution should be taken to insure that the device is not subjected to temperatures above its rated peak temperature for an extended period of time. For details on both attachment techniques, precautions, and handling procedures recommended, please refer to: “Quad Flat No-Lead Module Solder Reflow & Rework Information”, Document Number QAD-00045 “Handling, Packing, Shipping and Use of Moisture Sensitive QFN”, Document Number QAD-00044 Caution! Class 1A ESD sensitive device Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 9 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Branding Information SiGe 5007B Lot Code Figure 6: SE5007BT Branding Tape and Reel Information Parameter Devices Per Reel Reel Diameter Tape Width Value 3000 13 inches 12 millimeters Figure 7: SE5007BT-R Tape and Reel Information Document Change History Revision Date Notes 1.0 Nov 03, 2010 Created 1.1 Nov 22, 2010 Updated Supply voltage specs 1.2 Dec 20, 2010 Corrected RX Conditions in Control Logic table 1.3 Jan 03, 2011 Updated recommended storage temperature 1.4 Feb 8, 2011 Added 4V operation, Mask Performance, Added reference to blocked RF ports on the block diagram 1.5 Apr 25, 2011 Update VENH (min) from 2.8V to 1.6V Corrected product description – removed reference to Balun 1.6 Apr 11, 2012 Updated with Skyworks logo and disclaimer statement Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 10 DATA SHEET SE5007BT: 5 GHz Front-End Module with Power Detector Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202448A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 25, 2012 11