V - Teledyne Cougar

Analog Level Detectors
10 to 1000 MHz
Technical Data
UTD-1000/1001
Features
Description
Pin Configuration
• –120 mV Output for –10 dBm
Pin
The UTD-1000 has an input
impedance of 50 ohms. The
UTD-1001 has an input impedance
of greater than 300 ohms. In all
other respects the detectors are
similar. The level detector consists of an amplifier stage that
drives a Schottky-barrier detector
diode. Matched back-to-back
silicon diodes which are closely
thermally-coupled to the detector
provide a DC tracking reference.
TO-8F
• ±1.0 dB Flatness
• 50- or 300-Ohm Impedance
Applications
• Specifically Designed for
System Built-in Test
• RF/IF Monitor
• Level Control
GROUND
RF
IN
VIDEO
V+
REFERENCE
• UTD-1001 Can Be Used
Without a Coupler in Many
Cases
Schematic
Maximum Ratings
+
Parameter
V
RFIN
R
1000
pF
–ID*
Detector
+ID*
Reference
R
* Requires external bias resistors
see “Application Note”, Section 7.
Bias Current (diode)
Continuous RF Input Power
Operating Case Temperature
Storage Temperature
“R” Series Burn-In Temperature
Pulse Input Power (1.0 minute max.)
Junction Temperature Above Case Temperature
Weight: (typical) 2.1 grams
Maximum
1 mA
+17.0 dBm
–54°C to +125°C
–62°C to +150°C
+125°C
100 mW
3°C
2
Electrical Specifications
(Measured in 50 Ω system @ +15 VDC nominal)
Symbol
—
—
—
—
—
—
—
—
—
Typical
Guaranteed Specifications
TC = 25°C TC = 0 to 50°C TC = –55 to +85°C
Characteristic
Detected Voltage (Min.)
f = 500 MHz, cond.1,2
Flatness (referred to input) (Max.)
f = 10-1000 MHz, cond.1,2
Variation Over Temperature
(referred to input), f = 500 MHz, cond.1,2,3
Input VSWR, 50 Ω (UTD-1000 only) (Max.)
f = 10-500 MHz
Input Impedance (UTD-1001 only)
Equivalent resistance
Equivalent capacitance
Input 3rd Order Intercept Point
f = 10-500 MHz
Output Offset Voltage (Max.)
ID = IREF = 50 µA, no RF drive
Differential Voltage Tracking
Output Capacitance
Conditions:
–120
–90
—
mV
±0.7
±1.0
—
dB
±1.0
—
—
dB
1.5:1
1.7:1
—
—
300Ω
3.3 pf
—
—
—
—
—
—
+20
—
—
dBm
±10.0
±5.0
1000
±15.0
—
1300
—
—
—
mV
mV
pf
1. ID = 50 µA, R = 10K Ω
2. PIN = –10 dBm (RF input)
3. Typical variation over –55° to +85°C
Product Options
UTD – 2002 R
Screening Option
blank = No Screening required
R = R-Series Screening
Model Number Prefix
UTDPPD-
For more information on R-Series screening,
see Reliability Screening, Pub. 5963-3240E.
Model Number
ATD – 18021– 1 R
Screening Option
blank = No Screening required
R = R-Series Screening
Model Number Prefix
ATDModel Number
For more information on R-Series screening,
see Reliability Screening, Pub. 5963-3240E.
Connector Options
Connector Option Table
Dash No.
-1
-2
-3
-4
-5
RF
IN
RFOUT
Female
PIN
Male
Male
Female
Female
PIN
Male
Female
Male
Unit
Contact your nearest HP sales office and/or
distributor for assistance in ordering this product.
3
Typical Performance @ 25°C
Key: +25 °C
+85 °C
-55 °C
Detected Output
vs. Power Input
1000
RL =
100 KΩ
100
10 KΩ
f = 500 MHz
PIN = –10 dBm
10
1
1 KΩ
10
100
Diode Current, µA
Detected Voltage, mV
Detected Voltage, mV
Detected Output
vs. Diode Bias Current
100
1000
f = 500 MHz
ID = 50 µA
10
–20
RL =
100 KΩ
120
PD = –10 dBm
10 KΩ
100
80
ID = 50 µA
200
800
ID = 100 µA
44
45
47
1000
10 KΩ
ID = 50 µA
0
200
400
600
Frequency, MHz
800
1000
Third Order Two–Tone*
Intercept Point
40
24
38
22
IP3, dBm
IP2, dBm
+5
RL =
1 KΩ
43
Second Order Two–Tone*
Intercept Point
36
34
32
30
0
46
1 KΩ
400
600
Frequency, MHz
–10
–5
Power Input, dBm
Tangential Signal Sensitivity
140
0
–15
41
42
TSS, dBm
Detected Voltage, mV
DC Output
160
60
RL =
100 KΩ
10 KΩ
1 KΩ
1000
20
18
16
14
0
200
400
600
Frequency, MHz
800
1000
0
200
400
600
Frequency, MHz
* Distortion Curves relative to the UTD-1001 operated in shunt with a 50Ω RF line.
(See “Application Note” in Section 7.)
800
1000
Case Drawings
TO-8F
.300
TYP
.175
.017
+.002
- 001
.150
TYP
GROUND
RF OUT
3
4
.150
TYP
1
45
.031
.031
GLASS RING
.060 DIA TYP
(4X)
2
.50
.450
DIA DIA MAX
0.185
±0.015
RF IN
5
CASE
GROUND
CONTROL
V+
.075
APPROXIMATE WEIGHT 2.1 GRAMS
NOTES (UNLESS OTHERWISE SPECIFIED):
1. DIMENSIONS ARE SPECIFIED IN INCHES
2. TOLERANCES: xx ± .02
xxx ± .010
Contact Teledyne Microwave Solutions:
650-691-9800
650-962-6845 fax
Check for updates:
www.teledynemicrowave.com