UPS UPS-1500-S-1U UPS-1500-E-2U M ilitary G rade U ninterruptible P ower S upply 1500VA/ 1250W Output Power 80-265Vrms 47-65Hz or 47-800Hz AC Input Voltage Options 115Vrms or 230Vrms 50Hz, 60Hz or 400Hz AC Output Voltage Options 28 Vnom DC Input Voltage Option 500W or 1250W DC Output Voltage Option >10 Min. - 1U >24 Min. - 2U Battery Run Time Options Sealed Construction, Ultra low Weight, Compact Size Designed & Manufactured in USA SynQor’s Military-Grade Uninterruptible Power Supply units are designed for the extreme environmental and demanding electrical conditions of Military/Aerospace applications. SynQor’s UPS incorporates field proven high efficiency designs and rugged packaging technologies. This UPS will accept a wide range of input voltage and frequency values while delivering a well-conditioned AC output to the load. The use of lithium polymer batteries permits the lowest profile and lowest weight solution in its power class. It is designed and manufactured in SynQor’s USA facilities to comply with a wide range of military standards. Options include two DC outputs and the ability to also draw power from a military standard 28VDC input. Combine Up to 3 units for Higher Power, Voltage and/or 3-phase AC output Features • Sealed, weather-proof, shock-proof construction • Hot swappable internal battery pack (lithium polymer) • >10 minute run-time at full power • 1250W (1500VA) output power • Full power operation: -20°C to +55°C • Universal AC input: 80-265VAC; 47-65Hz • Power factor correction at AC input • Dual input (AC and optional DC) • True on-line double conversion • Cold start with no AC or DC input connections • Pure sinusoidal AC output voltage (115VAC, 60Hz) • Handles 0.0—1.0 power factor loads and non-linear loads • Up to 3 units can be combined for higher power, voltage or a 3-phase AC output • User I/O and Configuration signal ports • 1U high rack mount unit (17” x 21.6”) • Low weight: 32 lbs. (including battery) In-Line Manufacturing Process • AS9100 and ISO 9001 certified facility • Full component traceability Product # UPS-1500X Phone 1-888-567-9596 Options • DC input (28Vnom) for dual source • 2U Extended battery pack gives >24 minutes of run-time • Wide-range AC input frequency: 47Hz to 800Hz • 115Vrms or 230Vrms AC output • 50Hz, 60Hz, or 400Hz output • DC1: Auxiliary isolated DC output (up to 500W) • DC2: High power DC output (up to 1250W) parallelable for higher power • Shipboard version with floating neutral wire Specification Compliance UPS-1500 units are designed to meet: • MIL-STD-1399-300B - Interface Std for Shipboard Systems • MIL-STD-810G - Environmental Engineering Considerations • MIL-STD-461F - Electromagnetic Interference • MIL-STD-704F - Aircraft Electrical Power Characteristics • MIL-STD-1275D - Vehicle Electrical Power Characteristics Contents Technical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessory Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . www.synqor.com Doc.# 005-0006173 Rev. O 09/02/2015 2 4 7 8 Page 1 UPS UPS-1500-S-1U UPS-1500-E-2U Technical Specification INPUT CHARACTERISTICS ENVIRONMENTAL CHARACTERISTICS MIL-STD-810G Operating AC Input MTBF 100kHrs MIL-217F Ground Benign, Ta=25°C Voltage 80-265Vrms* Temperature Methods 501.5, 502.5 Frequency 47-65Hz Operating Temperature -20°C — +55°C (47-800Hz Optional) Storage Temperature -20°C — +65°C >0.98 at 47-65Hz Altitude Method 500.5 >0.97 at 400Hz Operating >0.93 at 800Hz Non-operating Maximum Input Current Continuous 20A (full load, 85Vrms) Electromagnetic Capability AC Input Circuit Breaker Rating 25A Input Power Factor 0 - 15,000 ft 0 - 40,000 ft MIL-STD-461F CE101 30 Hz - 10 kHz (* Power Derating to 80% below 90Vrms) CE102 10 kHz - 10 MHz Operating DC Input (Optional) CS101 30 Hz - 150 kHz Voltage 22-33V CS106 10 kHz - 40 GHz Continuous Maximum Input Current 62A (full load, 22V) CS114 10 kHz - 200 MHz Transient Maximum Input Current 75A CS116 10 kHz - 100 MHz OUTPUT CHARACTERISTICS RE101 30 Hz - 100 kHz Total Output Power Continuous 1250W (1500VA) RE102 10 kHz - 18 GHz Maximum DC1 Output Power 510W RS101 30 Hz - 100 kHz Maximum DC2 Output Power 1250W RS103 2 MHz - 40 GHz (Note: Available AC power is reduced by power delivered to the DC output) Environmental Tests AC Output Shock/Drop Method 516.6, Procedures 1,4,6 AC Output Waveform Pure Sinusoidal Vibration Method 514.6, CAT 5, 7, 8, 9, 24 Voltage 115Vrms ± 3% Fungus 230Vrms ± 3% Salt Fog 60Hz ± 0.5% Sand and Dust 50Hz ± 0.5% Rain Method 506.5 400Hz ± 0.5% EMI MIL-STD-461F 26A (115Vrms) Humidity Frequency Peak Load Current Method 508.6 Method 509.5 13A (230Vrms) Mechanical Vibrations of Load Power Factor 0-1.0 (leading or lagging) Shipboard Equipment Total Harmonic Distortion 2% (1000W resistive load) MECHANICAL CHARACTERISTICS Chassis Size (H x W x D) Voltage Regulation (Over Load & Temperature) ± 3% Common Voltage/Power combinations (DC1) Method 528 1.73"(1U) x 17.00" x 21.60" 12V at 42A =504W Case Material 15V at 34A =510W Total Weight 24V at 21A =504W 28V at 18A =504W 40V at 12.5A =500W 50V at 10A =500W Optional 2U Extended Internal Battery Pack 3.33"(2U) x 17.00" x 21.60" Chassis Size (H x W x D) Aluminum Case Material 50 lbs. (with chassis & battery) Total Weight Connectors AC Input Connector MS3470L14-4P DC Input Connector MS3470L18-8P AC Output Connector MS3470L14-4S DC1 Output Connector MS3470L14-4SW DC2 Output Connector MS3470L18-8S User I/O Ports HD DB15 Female Configuration I/O Port HD DB15 Male Cooling Exhaust Fans Sound Pressure Level (SPL) 54 dB(A) Air Flow 0.67(m3/min) 23.7 CFM Two fans in system, above specs are for each fan separately. DC2 Output (optional) Voltage Setpoint ± 3% No Sharing Voltage Regulation (Over Load & Temperature) -2% Common Voltage/Power combinations (DC2) 24V at 50A =1200W 28V at 44.6A =1250W Droop Share (Output droops vs. load to allow passive sharing among modules.) 24V Option Voltage Regulation (Over Load & Temperature) -15% 26V at 0A 22V at 50A =1100W 28V Option Voltage Regulation (Over Load & Temperature) -13% 30V at 0A 26V at 48.1A =1250W Product # UPS-1500X Method 507.5 Standard 1U Battery Pack DC1 Output (optional) (Other Options Available) Method 510.5, Procedures 1,2 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006173 Rev. O Aluminum 32 lbs. (with chassis & battery) 09/02/2015 Page 2 UPS UPS-1500-S-1U UPS-1500-E-2U Technical Specification 5 1 10 15 6 11 High Density DB15 Female (15 Pin Connector) Signal PIN Function TX 2 RS232 DCE Device Transmit RX 3 RS232 DCE Device Receive GND 4, 5 Ground reference for all digital inputs and outputs LOW_BATT 6 Open collector output where “low” indicates battery charge level <10% ACIN_GOOD 7 Open collector output where “low” indicates AC Input voltage is within range +5V 8 Vout with minimal current drive usable as a pull-up voltage for open collector output signals. Load must be <35mA ON_BATT 9 Open collector output where “low” indicates that the UPS is running on battery power. REMOTE_START 12 Drive this line “high” with ≥5mA to enable UPS outputs SHUTDOWN 13 Drive this line “high” with ≥5mA to disable UPS outputs OUT_OK 14 Open collector output where “low” indicates AC Output voltage is within range OVER_TEMP 15 Open collector output where “low” indicates that the UPS is at or above its maximum temperature Safety & Qualifications IEC 62133 Safety requirements for portable secondary sealed cells. ST/SG/AC.10/11/Rev.5 UN Recommendations on the Transport of Dangerous Goods UL 1642 Lithium Batteries EN 62040-1:2009 General and safety requirements for UPS (Does not apply to 400Hz operation) EN 62040-2:2006 UPS Electromagnetic compatibility (Category C4) LITHIUM-POLYMER BATTERY CHARACTERISTICS Standard 1U Battery Pack Run Time 1250W : 10 min Optional 2U Extended Battery Pack Run Time 1250W : 24 min 1000W : 13 min 625W : 21 min 1000W : 31 min Recharge Time (to 90% charge) 625W : 50 min Standard Total Output Power < 1000W Optional 2U Extended Battery Pack Total Output Power < 1000W Temperature Range for Recharge: 0°C to 45°C Internal heaters maintain battery temperature above 0°C when input power is present. Battery charging only enabled below +45°C. Product # UPS-1500X Phone 1-888-567-9596 www.synqor.com 2 hrs 4 hrs Doc.# 005-0006173 Rev. O 09/02/2015 Page 3 UPS UPS-1500-S-1U UPS-1500-E-2U Mechanical Features Status LED UPS-1500-1U UNIT Status Indicator Panel 1.73" 1U Air intakes On/Off 17.00" UPS-1500-1U UNIT with DC Input/DC1 Output Options DC1 Output Option AC Output Exhaust Fan Ethernet Port I/O User Config Ground Option Port Port Stud (1/4-20) DC Input Option Exhaust Fan AC Input AC Circuit Breaker UPS-1500-1U UNIT with DC1 Output/DC2 Output Options DC1 Output Option Product # UPS-1500X AC Output Exhaust Fan Ethernet Port Option Phone 1-888-567-9596 I/O Port User Config Port www.synqor.com Ground DC2 Stud Output (1/4-20) Option Exhaust Fan Doc.# 005-0006173 Rev. O AC Input 09/02/2015 AC Circuit Breaker Page 4 UPS UPS-1500-S-1U UPS-1500-E-2U Mechanical Features UPS-1500-E-2U Status LED Front Panel Status Indicator Panel 3.33" 2U Air Intake On/Off 17.00" Rear Panel UPS Units with DC Input / DC1 Output Options DC1 Output Option AC Output Exhaust Fan Ethernet Port Option User I/O CONFIG Port Ground DC Stud Input (1/4-20) Option Exhaust Fan AC Input AC Circuit Breaker AC Input AC Circuit Breaker Rear Panel UPS Units with DC1 Output / DC2 Output Options DC1 Output Option Product # UPS-1500X AC Output Exhaust Fan Ethernet Port Option Phone 1-888-567-9596 User I/O CONFIG Port www.synqor.com Ground DC2 Stud Output (1/4-20) Option Exhaust Fan Doc.# 005-0006173 Rev. O 09/02/2015 Page 5 UPS UPS-1500-S-1U UPS-1500-E-2U Block Diagram AC INPUT AC to DC w/ PFC and ISOLATION ISOLATED INVERTER AC OUTPUT DC INPUT ELECTRONIC SWITCH / Non-Isolated DC-DC CONVERTER ISOLATED DC-DC CONVERTER DC1 OUTPUT (OPTIONAL) (OPTIONAL) (Not available with DC2 Option) ISOLATED DC-DC CONVERTER DC2 OUTPUT (OPTIONAL) BATTERY BULK ENERGY STORAGE CAPACITOR with CHARGER and ELECTRONIC SWITCH Product # UPS-1500X Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006173 Rev. O 09/02/2015 Page 6 UPS UPS-1500-S-1U UPS-1500-E-2U Mechanical Diagrams 19.450 21.60 18.700 9.750 .750 .75 1.50 UNIT MOUNTING HOLES 8-32 .250 x26 17.00 .55 .625 .313 1.73 Product # UPS-1500X Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006173 Rev. O 09/02/2015 Page 7 UPS UPS-1500-S-1U UPS-1500-E-2U Extended Mechanical 19.450 18.700 21.60 9.750 .750 .75 1.50 UNIT MOUNTING HOLES 8-32 .250 x52 2.375 3.33 MADE IN USA UPS Product # UPS-1500X Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006173 Rev. O .55 2.062 1.749 .625 .313 09/02/2015 Page 8 UPS UPS-1500-S-1U UPS-1500-E-2U Accessory Options Replacement Battery Packs 1500S Series 1500E Series 1U; 10 lbs. (200 Watt Hours) BAT-0200-S-1U-000 2U; 21 lbs. (500 Watt Hours) BAT-0500-E-2U-000 Rail Kits SYN-9002 Slide Rail Kit2 Fixed Bracket Kit3 SYN-9031 SYN-9033 Power Cables (10' long) AC Input (NEMA 5-20 Plug) SYN-9101 AC Input (NEMA 5-15 Plug) SYN-9104 AC Input (Hardwire) SYN-9102 AC Output (115Vrms) (NEMA 5-20 Receptacle) SYN-9131 AC Output (Hardwire) SYN-9130 DC Input (Ring Connectors) SYN-9151 DC Input (Hardwire) SYN-9152 DC Input (NATO Connector) SYN-9154 DC1 Output (Fork Connectors) SYN-9171 DC1 Output (Hardwire) SYN-9172 DC2 Output (Hardwire) SYN-9174 DC2 Output (Fork Connectors) SYN-9175 AC Output Power Strips (Circular Connector) 6 NEMA Receptacles with Breaker (1U Rackmount & 3' Cable) SYN-9232 6 NEMA Receptacles (1U Rackmount & 3' Cable) SYN-9231 Rackmount Transit Cases Transit Case, 3U, Gray, with Casters3 SYN-9410 Transit Case, 3U, Gray, No Casters3 SYN-9412 Notes: 1: Other Options also available, check the website or contact [email protected] for further information. 2: Slide Rail Kit (SYN-9002) is not recommended for transit and ruggedized use. 3: Fixed Bracket Kit (SYN-9031) with Transit Case (SYN-9410 or SYN-9412) is required for transit and ruggedized use (qualified to pass MIL-STD-810G Loose Cargo andTransit Drop requirements). User Communications (I/O) Cables HD DB15M to DB9F (RS232, 10') SYN-9301 HD DB15M to DB15M (RS232 and Digital I/O, 10') SYN-9305 Mil-Circular to RJ45 (Ethernet, 10') SYN-9321 Configuration Cables Optional Rackmount Transit Case HD DB15F to DB15F (2 Units Parallel, 3') SYN-9311 HD DB15F to DB15F (3 Units Parallel, 6') SYN-9315 HD DB15F to DB15F (2 Units Series, 3') SYN-9313 HD DB15F to DB15F (3 Units 3 Phase, 6') SYN-9317 6 NEMA Receptacles with Breaker Product # UPS-1500X Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006173 Rev. O 09/02/2015 Page 9 UPS UPS-1500-S-1U UPS-1500-E-2U Ordering Information PART NUMBERING SYSTEM Model Number Power Options Battery AC Input AC Output AC Output Run-Time Floating Height Weight DC Input Frequency Voltage Frequency @ Full Power DC Output Neutral (28V nom) (47-65Hz or (115Vrms or (50Hz, 60Hz (80% Power) AC Output 47-800Hz) 230Vrms) or 400Hz) UPS-1500-S-1U 1250W (1 Standard Battery Pack) 1500VA >10 min. (>13 min.) 1U 32 lbs. • 500W DC1 1250W DC2 • • • • UPS-1500-E-2U 1250W (1 Extended Battery Pack) 1500VA >24 min. (>31 min.) 2U 50 lbs. • 500W DC1 1250W DC2 • • • • Family Output Power UPS 1500 Battery Pack Height Size E 2U AC Input AC Output Frequency Voltage L AC Output AC Neutral Output Wire Set Point 1 G 6 S: Standard 5: 50Hz 1500VA 1U: 1.73" L:47 - 65Hz 1: 115Vrms G: Grounded UPS 1500: E: Extended 6: 60Hz 1250W 2U: 3.33" W:47-800Hz 2: 230Vrms F: Floating * N: No Battery 4: 400Hz Not all combinations make valid part numbers, please contact SynQor for availability. See the Product DC Input / DC2 Output DC1 Additional Options Output D 28 S: Not Installed D: DC Input M: DC2 Out 24VDC with Droop Share 00: None P: DC2 Out 12: 12V 24VDC 24: 24V No Sharing 28: 28V R: DC2 Out 40: 40V 28VDC with 50: 50V Droop Share V: DC2 Out 28VDC No Sharing Summary web page for more E00 000: None 0CE: CE Marking E00: Ethernet / SNMP ECE: Ethernet / SNMP & CE Marking options. * Note: Order “F: Floating” option when configuring the AC output for multi-unit combinations. Examples: UPS-1500-E-2U-L1G6D28-000, UPS-1500-S-1U-L2G5S00-E00 UPS-1500-S-1U-L2G5S00-0CE (230V output with CE marking) Contact SynQor for further information and to order: Phone: Toll Free: Fax: E-mail: Web: Address: Product # UPS-1500X 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 PATENTS SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter products. Any that apply to the product(s) listed in this document are identified by markings on the product(s) or on internal components of the product(s) in accordance with U.S. patent laws. SynQor’s patents include the following: 5,999,417 6,222,742 6,545,890 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702 7,765,687 7,787,261 8,023,290 8,149,597 8,493,751 8,644,027 WARRANTY SynQor offers a 1 year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. www.synqor.com Doc.# 005-0006173 Rev. O 09/02/2015 Page 10