i4 Series Combination Carbon Monoxide(CO)/Photoelectric Smoke Detector COSMO-2W (2-wire) and COSMO-4W (4-wire) 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6583 www.systemsensor.com SpecificationsCOSMO-2W COSMO-4W Electrical Specifications Physical Spcecificaitons System Voltage: 12/24 volts DC 12/24 volts DC Operating Temperature Range: 0 - 50° C (32 - 122° F) Min: 8.5 volts 8.5 volts Operating Humidity Range: 20-95% RH Max: 35 volts 35 volts Storage Temperature Range: -10 - 70° C (14 - 158° F) Max Startup Current: 200uA200uADiameter: 5.5 inches Max Standby Current: 50uA50uAHeight: 2.5 inches Max Alarm Current: 50mA 40mA Weight: 9.2 oz; 261 g Max Reverse Polarity Current: 20mA 20mA Wire Gauge Acceptance: Min: 22 AWG Max: 14 AWG Audible Signal (Supplemental*): 85dBA 85dBA 2-Wire Compatibility Zone Identifier: A Max Start-up Capacitance: .10uF .10uF *NFPA requires a UL listed sounder on the NAC circuit alarm and CO alarm events. The red LED signals smoke events; it blinks during smoke maintenance events and lights constantly during smoke alarm events. The blue LED signals CO events; it blinks blue during CO trouble or CO end-of-life; it blinks rapidly during RealTest®; and lights constant during CO alarm. Notice: T his manual shall be left with the owner/user of this equipment. BEFORE INSTALLATION Please read this manual thoroughly along with manual I56-3871 for the i4 series interface module and the Application Guides for System Sensor Smoke (A05-1003) and CO Detectors (A05-1099), which provide detailed information on detector spacing, placement, zoning, wiring, and special applications. Copies of these manuals are available at systemsensor.com. TABLE 1: OPERATION MODES IMPORTANT: This detector must be tested and maintained regularly following NFPA 72/NFPA 720 requirements. At a minimum, cleaning and testing should be performed annually. GENERAL DESCRIPTION The i4 series is a plug-in, system-connected, combination carbon monoxide/ smoke detector. It is available in either a 2-wire or 4-wire configuration. The i4 series detectors must be used with the corresponding i4 series Interface Module to connect to the panel. The i4 interface module is also compatible with i3 series smoke detector model 2WTA-B or 4WTA-B. FEATURES Smoke Features Green LED Red LED Normal (standby) Blink 5 Sec. OFF OFF Blue LED Sounder OFF Alarm Smoke OFF ON OFF Temp 3 Alarm CO OFF OFF ON Temp 4 Alarm Smoke & CO OFF ON ON Temp 3 RealTest® Mode OFF OFF Blink 1 Sec. OFF (After CO is Sprayed) OFF OFF ON Temp 4 Trouble feature: When the sensor (supervision) is in a trouble condition (such as a detector that is dirty), the detector will send a trouble signal to the module then to the FACP. Depending on the issue, the detector must then be serviced or replaced. • Photoelectric smoke sensor • Drift compensation and noise rejection algorithms • Red smoke LED indicator • Smoke test switch CO Features CO sensor end-of-life timer feature: When the CO sensor has passed end-oflife, a trouble signal will be sent to the module then to the FACP. This indicates that the CO sensor inside the detector must be replaced. If unresolved for 30 days, the detector will chirp intermittently. The typical life of the CO sensor is six years from the date of manufacture; it is recommended to periodically check the “Replace by” sticker located on the replaceable CO cell. • Field replaceable, electrochemical CO sensor • RealTest® functional test capable • Blue CO LED indicator • Sensor end-of-life notification Audible Annunciation INSTALLATION GUIDELINES Ceiling: Detector should be at least 12 inches from any wall. Wall: Detector should be no closer than 6 inches from ceiling. • Local integral sounder • Polarity reversal Installation and Maintenance • Do not install outdoors or in any environment that does not comply with the detector’s environmental specifications • Install in accordance with NFPA 72 and 720 standards. NFPA 72 and 720 define standards for both commercial and residential installation of smoke and CO detectors. State and local laws involving CO detection should also be considered. • If the installation can be interpreted as residential, consult the section of NFPA 720 that outlines residential applications. Chapter 9.4.1.1, for example, states that carbon monoxide alarms or detectors shall be installed as follows: • Outside each separate dwelling unit sleeping area in the immediate vicinity of the bedroom • On every level of a dwelling unit, including basements • Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/ or applicable codes for specific information regarding the spacing and placement of smoke detectors. • Do not install detectors in the following areas: • In or near areas where particles of combustion are normally present such as • Stop-Drop-N-Lock plug-in base • SEMS wiring terminals • COSMO-2W designed for 2-wire i4 Zone type • COSMO-4W designed for 4-wire i4 Zone type • SENS-RDR sensitivity reader compatible with extended range • Removable cover for cleaning • Replaceable screen Other Features • Green supervisory LED • Listed to UL standards 268 and 2075 VISIBLE ANNUNCIATON The i4 series detector has three visible LED’s; Green, Red and Blue. The green LED is a supervisory LED; it blinks during power on, reset, and during normal operation. It is extinguished during smoke maintenance, CO trouble, smoke SS-500-003 Operation Mode 1 I56-3747-001R I56-3747-001R INSTALLATION AND MAINTENANCE INSTRUCTIONS kitchens, in garages, near furnaces, hot water heaters, or gas space heaters. In very cold or very hot areas. In wet or excessively humid areas, or next to bathrooms with showers. In dusty, dirty, or insect-infested areas. Near fresh air inlets or returns or excessively drafty areas. Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke away from the detector. Note: This unit is UL listed as containing a supplemental sounder and should not be used as a primary sounder for evacuation. FIGURE 1: ALARM LOCATION DIAGRAM FOR RESIDENTIAL APPLICATION the end of the feed wire, inserting it into the proper base terminal, and tightening the screw to secure the wire in place. Do not put wires more than 2 gauge apart under the same clamping plate. • • • • WARNING Remove power from alarm control unit or initiating device circuits before installing detectors. 1.Remove detector from packaging and separate the base from the detector head. 2. Wire the detector base screw terminals. 3.Screw the base of the detector onto an electrical box, or to the surface of the wall or ceiling using the hardware included in the packaging. 4.Attach the detector head to the base by applying light pressure and rotating clockwise. The detector will lock in place when properly aligned. 5.After all detectors have been installed, apply power to the alarm control unit. Refer to Table 3 for time to LED stabilization. Once stabilized, the green LED will blink once every 5 seconds. 6. Test each detector as described in the Testing section. 7. Notify the proper authority that the system is in operation. BEDROOM BEDROOM TO BR BEDROOM KITCHEN LIVING ROOM GARAGE CLOSED DOOR CAUTION S0295-01 NFPA 72 recommends the installation of detectors only after completing construction or any other dust producing activity BASEMENT – CARBON MONOXIDE/SMOKE ALARM TABLE 2: LED INDICATION DURING POWER UP SEQUENCE LOCATION FOR MULTI-LEVEL RESIDENCE MOUNTING The i4 detector can be ceiling mounted or wall mounted: No Power 1.To a single gang box, 2 in. by 4 in. box, 3½ in. or 4 in. octagonal or 3½ in. or 4 in. round ceiling 2. Direct mount to ceiling or to wall using drywall fasteners FIGURE 2: MOUNTING OF DETECTOR Power on Reset Green LED Red LED Blue LED OFF OFF Blink 5 Sec. Blink 5 Sec. OFF Blink 5 Sec. TABLE 3: POWER UP TIME TO FIRST ALARM / LED STABILIZATION S0326-00 Power Up Time 45 Seconds Power up time after 10 second reset 15 Seconds LED Indication time Typical: 45 seconds Maximum: 55 seconds Status LED indication stabilization time Typical: 55 seconds Maximum: 268 seconds TESTING The detector must be tested after installation. The detector has two discrete test switches, one for smoke testing and one for CO testing. The detector may also be functionally tested using canned smoke and canned CO. WIRING INSTALLATION GUIDELINES All wiring must be installed in compliance with the NFPA 70 standards, National Electrical Code, applicable state and local codes. The screw terminals in the mounting base will accept 14-22 gauge wire. Wire connections are made by stripping approximately 3/8" to ½" of insulation from NOTE: Before testing, notify the proper authorities to avoid any nuisance alarms. Ensure the proper wiring and power is applied to the detector. After power up, allow approximately 5 minutes for the detector to stabilize before testing. FIGURE 3: COSMO-2W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED (EXCEPT TRIGGERS) AND MUST BE POWER LIMITED SMOKE AUXPOWER (resettable) Panel EOL Resistors SMOKE ZONE 3.9k RESISTOR (supplied with module) CO ZONE MAINT. ZONE BELL Panel EOL Resistor LOOP STYLE D WIRING COSMOD2W COSMO-2W OR SMOKE TRIGGER OUT S0329-00 CO TRIGGER OUT SS-500-003 2 I56-3747-001R FIGURE 4: COSMO-4W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED (EXCEPT TRIGGERS) AND MUST BE POWER LIMITED SMOKE POWER (resettable) Panel EOL Resistors SMOKE ZONE EOL RELAY #EOLR-1 3.9k RESISTOR (supplied with module) CO ZONE COSMO-4W COSMOD4W BELL OR SMOKE TRIGGER OUT S0330-00 CO TRIGGER OUT FIGURE 5: TEST BUTTON LOCATION AND OPERATION 3.If the detector is within the listed sensitivity limits, the sounder will alarm temporal 3 and the red alarm LED will light up. Smoke Sensitivity Reading To measure the detector’s smoke sensitivity, the Infrared Sensitivity Reader model #SENS-RDR should be used. TEST BUTTON SMOKE 1.Point the SENS-RDR directly to the center of the detector at a distance of 1 to 10 feet. A broomstick can be attached to the SENS-RDR for extended reach. 2.The sensitivity will be displayed on the SENS-RDR. The SENS-RDR will also display “replace” if a detector is found faulty. Smoke Entry Test 1.With the detector in standby mode, spray UL listed compatible, canned smoke into the detector. 2.When the detector senses the presence of the smoke, the sounder will alarm temporal 3 and the red alarm LED will illuminate. Note: On some panels, resetting a smoke alarm may require additional steps at the keypad to clear the trouble conditions on CO and smoke maintenance zones due to power loss to the module. Loop Verification (Model #COSMO-2W only) Loop verification is provided by the EZ Walk loop test feature. This feature is for use with compatible control panels and System Sensor 2-wire detectors (i4 Series model COSMO-2W and i3 Series model 2WTA-B) installed with the COSMOD2W interface module only. The EZ Walk loop test verifies the initiating loop wiring and provides visual status indication at each detector: GAS ENTRY PORTS S0327-00 TEST BUTTON CARBON MONOXIDE TABLE 4: LED INDICATION & SOUNDER DURING TEST AND MAINTENANCE Smoke Maintenance CO Trouble/ End-of-Life Green LED Red LED Blue LED OFF Blink 5 Sec. OFF OFF Blink 5 Sec. Intermittent chirp after 30 days OFF OFF Sounder Simultaneous Smoke Maintenance & CO Trouble/EOL OFF Blink 5 Sec. Blink 5 Sec. OFF Double Blink 5 Sec. OFF OFF OFF Double Blink 5 Sec. OFF OFF OFF Double Blink 5 sec. OFF EZ Walk Test® – Normal 1.Ensure proper wiring and power is applied. Wait approximately 6 minutes after power-up before performing the EZ Walk test. 2.Place COSMOD2W interface module into EZ Walk test mode by depressing the recessed test button on the COSMOD2W Interface Module. 3. Observe the LED’s at each detector. NOTE: The EZ Walk loop test should not be used in lieu of functional testing (alarm, trouble and other functional tests) of the system. CO Test Switch 1.A recessed CO test switch is located on the detector housing and identified by text that says “TEST” next to it and “CARBON MONOXIDE” above it. (See Figure 5) 2.With the detector in standby mode, use a small screwdriver to press and release the CO test switch. Pressing the switch one time will enter into RealTest® Mode (see instructions below), pressing two times will enter test mode. 3.If the test is successful, the blue LED will light up. The detector and module will automatically reset within 60 seconds. If the detector fails either of the above test methods the CO cell or the detector should be replaced. EZ Walk® – Smoke Maintenance OFF EZ Walk® – CO Trouble/End-of-Life OFF EZ Walk® – Smoke Maintenance & CO Trouble/End-of-Life OFF Double Blink 5 sec. Double Blink 5 sec. OFF *NOTE: EZ Walk applies to COSMO-2W 2-wire model only. Smoke Test Switch 1.A recessed smoke test switch is located on the detector housing and identified by text that says "TEST" next to it and “SMOKE” above it. It is the switch closest to the red LED. (See Figure 5) 2.With the detector in standby mode, use a small screwdriver to press and release the smoke test switch. SS-500-003 3 I56-3747-001R FUNCTIONAL GAS TEST Solo C6 brand canned CO may be used to verify the detector’s ability to sense CO by utilizing the RealTest® feature as follows: 3.Remove the white cover of the screen/sensing chamber located in the center of the detector head by turning counterclockwise. 4. Remove the black screen/sensing chamber by pulling up on it. 5.Use canned air to remove any dust or particles that are present on both the chamber cover/screen and chamber itself. 6.Replace the top half of the screen/sending chamber by aligning the two arrows on the chamber cover with the notches in the detector head. Press down until the screen/sensing chamber is fully seated. 7.Replace the white cover by placing it over the screen/sensing chamber and turning it clockwise until it snaps into place 8.Reattach the detector head to the base by applying light pressure and rotating clockwise. The detector will lock in place when properly aligned. 9. Test the detector to insure it is fully functional. (See Testing section) 10. Notify the proper authorities when the system is back in service. 1.Press and release the test switch once as described in Testing above. The blue LED will start blinking rapidly indicating it is RealTest® mode. If the detector will not go into RealTest® mode, the CO sensor may be in fault or at end-of-life. 2.While the blue LED is blinking, spray a small amount of canned CO directly into the CO gas entry ports from ¼” away. (See Figure 5) 3.The detector will go into alarm if the gas entry was successful and the cell is functioning properly. 4.The CO test will automatically clear when the CO clears or in 30 seconds if no CO was introduced. NOTE: Testing the detector will activate the alarm and send a signal to the panel. Carbon monoxide gas may be present in other areas. This detector is NOT: FIGURE 6: REMOVING/REPLACING SCREEN/SENSING CHAMBER • A substitute for the proper servicing of fuel-burning appliances or the sweeping of chimneys. • To be used on an intermittent basis, or as a portable alarm for the spillage of combustion products from fuel-burning appliances or chimneys. Carbon monoxide gas is a highly poisonous gas which is released when fuels are burnt. It is invisible, has no smell and is therefore impossible to detect with the human senses. Under normal conditions in a room where fuel burning appliances are well maintained and correctly ventilated, the amount of carbon monoxide released into the room by appliances should not be dangerous. Do not paint, and do not use cleaning agents, bleach or polish the detector. Symptoms of carbon monoxide poisoning Carbon monoxide bonds to the hemoglobin in the blood and reduces the amount of oxygen being circulated in the body. The following symptoms are examples taken from NFPA 720; they represent approximate values for healthy adults. Concentration (ppm CO) Symptoms 200 Mild Headache after 2-3 hours of exposure 400 Headache and nausea after 1-2 hours of exposure 800 Headache, nausea, and dizziness after 45 minutes of exposure; collapse and unconsciousness after 2 hours of exposure Limited Life of CO Sensor This detector is manufactured with a long-life carbon monoxide sensor. Over time the sensor will lose sensitivity, and will need to be replaced. A replacement CO sensor, model #CO-REPL, is available. The life span of the CO sensor is approximately six years from the date of manufacture. Periodically check the detector’s replacement date. Remove the detector head and refer to the sticker placed on the replaceable CO cell.. The sticker will indicate the date the CO cell should be replaced. Reminder: T his detector is also equipped with a feature that will signal the panel once the CO sensor has passed the end of its’ useful life. If this occurs, it is time to replace the CO sensor. Replacement of CO Sensor 1. Remove the detector head by turning counterclockwise. 2. Locate the CO sensor on the back side of the detector head. (Refer to Figure 7) 3. Depress the 2 tabs on the CO sensor and pull it out. 4. Insert replacement CO sensor model CO-REPL. 5.Reattach the detector head to the base by applying light pressure and rotating clockwise. The detector will lock in place when properly aligned. 6. Test the detector to insure it is fully functional. (See Testing section) 7. Notify the proper authorities when the system is back in service. NOTE: Before replacing the sensor or detector, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. Disable the zone or system undergoing maintenance to prevent any unwanted alarms. Follow the proper testing protocol as outlined in the Testing section to make sure the device is functioning properly. Dispose of detector in accordance with any local regulations. Many cases of reported carbon monoxide poisoning indicate that while victims are aware that they do not feel well, they become so disoriented that they are unable to save themselves by either exiting the building or calling for assistance. Also young children and pets may be the first to be affected. CO ALARM ACTIVATION Per UL standard 2075, the i4 series detector has been tested to the sensitivity limits defined in UL standard 2034. TABLE 6: CO ALARM THRESHOLDS Parts per Million (ppm) Detector Response Time (Min.) 30+-3ppm No alarm within 30 days 70+-5ppm 60-240 150+-5ppm 10-50 400+-10ppm 4-15 What to do if the carbon monoxide detector goes into alarm: FIGURE 7: CO SENSOR REPLACEMENT Immediately move to a spot where fresh air is available, preferably outdoors. Find a phone in an area where the air is safe and call your security service provider. Tell your provider the detector alarm status, and that you require professional assistance in ridding your home of the carbon monoxide. MAINTENANCE NOTE: Before performing any maintenance on the detector, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. Disable the zone or system undergoing maintenance to prevent any unwanted alarms. Power must be removed from the detector before performing maintenance of any kind. Cleaning 1. Remove the detector head by turning counterclockwise. 2.Clean the outside casing with a cloth. Ensure that the holes on the front of the alarm are not blocked with dirt and dust. Canned air can be used to remove any dust or debris. SS-500-003 REPLACEABLE CO CELL 4 S0333-00 I56-3747-001R ©2012 System Sensor