CD100M Hand-Held CO2 and Temperature Monitor Features Patented dual beam, Absorption Infrared™ gas sensor ensures long term stability and durability. Large, easy to read display. Temperature displayed in °F or °C. CO2 displayed in ppm. Easily adjusted for altitude changes. Fast, simple calibration using external port and display. Calibrate with ambient air or bottled gas. Calibrate, set elevation, change °F or °C using on-board controls. Flip out stand for desktop monitoring. Analog output for data logging. Plug In AC power adaptor. Operates for up to 80 hours on 4 AA alkaline batteries. (not included). Applications Product Overview Identify areas with low or substandard ventilation. Equipped with Engelhard’s patented dual beam Absorption Infrared™ technology, the Innovair™ CD100M is an easyto-use CO2/temperature monitor designed for use in residential or commercial applications. With the ability to display CO2 readings in less than 30 seconds, the monitor is an ideal tool for: identifying energy saving opportunities in over-ventilated spaces, determining if air quality complaints are due to insufficient ventilation, or locating the presence of combustion fumes generated from vehicles and appliances. The Innovair™ CD100M is also equipped with an output for recording data. Identify hidden energy savings in over-ventilated spaces. Determine if ventilation is a factor in air quality complaints. Locate the presence of combustion fumes from vehicles and appliances. Use as a reference to calibrate wall mounted CO2 sensors. Featuring Specifications Output - Analog Method Dual Beam Absorption Infrared™ CO2 0-4 VDC, 1mV/ppm (4,000 ppm max) Sample Method Diffusion or flow through (50 - 100 ml/min) Temperature 0-4 VDC linear, 32–104°F (0-40°C) Output Impedance 100 Ohms Limited Warranty 18 months parts and labor Wiring Connection Via RJ-45 to DB9 serial port cable CO2 Channel Measurement Range 0-4,000 ppm voltage output 0-10,000 ppm display Display LCD with independent CO2/ temperature readings (panel buttons set elevation, °F/°C, calibration functions) Sensitivity ± 1 ppm Temperature Channel Accuracy ±50 ppm or ±5% of reading, whichever is greater Temperature Range Voltage output 32 to 104°F (0 to 40°C) Display 32 to 122°F (0 to 50°C) Repeatability ±20 ppm Display Resolution 0.1°F (0.1°C) Temperature Dependence ±0.1% of reading per °C or ±2 ppm per °C, whichever is greater, referenced to 25°C Display Options °F, °C, or Off. Set with panel button. Limited Warranty 18 months from date of manufacture Note Pressure Dependence: 0.13% of reading per mm Hg (Corrected via user input for elevation) Annual Drift ± 20 ppm typical Specifications subject to change without notice. Covered by United States Patents: 5,060,508 and 5,163,332 Accuracy ±2°F (±1°C) Response Time 20-30 minutes (case must equilibrate with environment) Response Time <60 seconds for 0–90% of step change Calibration Interval 12 months, offset adjustment using temperature standard at 50 to 86°F (10 to 30°C). Full factory calibration available Warm-Up Time <60 seconds at 22°C Power Supply Operating Conditions 32-122°F (0-50°C) Batter y Type Four AA batteries, not included 0–95% RH, non-condensing Batter y Operation 80 hours (alkaline) Storage Temperatures –40 to 140°F (–40 to 60°C) System Sensor seeks to present reliable information concerning the composition, properties and use of its products, however; (1) All advice concerning selection and use of any product is provided at no charge and with no warranty. (2) No warranty is made hereby. Products described herein are warranted to conform to System Sensor’s specifications only at the time of sale. All sales are subject to System Sensor’s standard terms and conditions, which are reproduced on the reverse side of each invoice. All warranties of merchantability and fitness of purpose are disclaimed and remedy for any breach of warranty is limited to replacement of the defective product. (3) System Sensor assumes no responsibility for any patent liability arising from the use of any product in a process, manner or formula not designed by System Sensor. External 6 VDC from external AC/DC adapter, included Calibration Interval 12 months, offset adjustment using single gas at 0-1000 ppm CO2. Full factory calibration available Power Requirements 100 mA Peak, 20 mA average from 6V Certification FCC Class 15 Part B Featuring Absorption Infrared™ is a trademark of Engelhard Sensor Technologies. Telaire® is a registered trademark of Engelhard Sensor Technologies. System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800-SENSOR2 Fx: 630/377-6495 Documents On Demand: 1-800-736-7672 x3 Web: www.systemsensor.com System Sensor in Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor in China Ph: 011.86.29.524.6253 Fx: 011.86.29.524.6259 System Sensor in the Far East Ph: 011.852.21919003 Fx: 011.852.27366580 System Sensor in Europe Ph: 011.44.1403.276500 Fx: 011.44.1403.276501 System Sensor in Singapore Ph: 011.65.273.2230 Fx: 011.65.273.2610 System Sensor in Australia Ph: 011.613.54.281.142 Fx: 011.613.54.281.172 © 1999 System Sensor. The company reserves the right to change product specifications without notice. A05-1039-00•11/99(5K)•#585