Features Regulated Converters Description ● ● ● ● ● ● ● 2:1 Wide Range Voltage Input 1kVDC, 2kVDC and 3kVDC Isolation Approved for Medical Applications Continuous Short Circuit Protection Low Ripple and Noise DIP16, mini DIP16 and SMD Cases Styles Efficiency to 83 % ECONOLINE DC/DC-Converter with 3 year Warranty High power-density, 2:1 input voltage range and a wide temperature range of -40°C to +85°C are just some of the characteristics of this versatile DIP16 converter, ideal for highly sophisticated industrial and medical designs where a regulated converter is required but space is at a premium. Three different case styles and isolation options are available. 2 Watt DIP16, Mini DIP16 & SMD Single & Dual Output Selection Guide Input Rated Output Output Current Efficiency Voltage Range Voltage Full Load typ./nom Vin DIP16 (Mini & SMD) (VDC) (VDC) (mA) (%) RW2-053.3S (H2/H3) 4.5 - 9 3.3 500 68 RW2-0505S (H2/H3) 4.5 - 9 5 400 73 RW2-0512S (H2/H3) 4.5 - 9 12 166 75 RW2-0515S (H2/H3) 4.5 - 9 15 134 75 RW2-123.3S (H2/H3) 9 - 18 3.3 500 69 RW2-1205S (H2/H3) 9 - 18 5 400 75 RW2-1212S (H2/H3) 9 - 18 12 166 80 RW2-1215S (H2/H3) 9 - 18 15 134 80 RW2-243.3S (H2/H3) 18 - 36 3.3 500 70 RW2-2405S (H2/H3) 18 - 36 5 400 78 RW2-2412S (H2/H3) 18 - 36 12 166 83 RW2-2415S (H2/H3) 18 - 36 15 134 83 RW2-483.3S (H2/H3) 36 - 72 3.3 500 73 RW2-4805S (H2/H3) 36 - 72 5 400 76 RW2-4812S (H2/H3) 36 - 72 12 166 81 RW2-4815S (H2/H3) 36 - 72 15 134 81 RW2-0505D (H2/H3) 4.5 - 9 ±5 ±200 73 RW2-0509D (H2/H3) 4.5 - 9 ±9 ±111 74 RW2-0512D (H2/H3) 4.5 - 9 ±12 ±83 75 RW2-0515D (H2/H3) 4.5 - 9 ±15 ±67 75 RW2-1205D (H2/H3) 9 - 18 ±5 ±200 75 RW2-1209D (H2/H3) 9 - 18 ±9 ±111 78 RW2-1212D (H2/H3) 9 - 18 ±12 ±83 80 RW2-1215D (H2/H3) 9 - 18 ±15 ±67 80 RW2-2405D (H2/H3) 18 - 36 ±5 ±200 78 RW2-2409D (H2/H3) 18 - 36 ±9 ±111 81 RW2-2412D (H2/H3) 18 - 36 ±12 ±83 83 RW2-2415D (H2/H3) 18 - 36 ±15 ±67 83 RW2-4805D (H2/H3) 36 - 72 ±5 ±200 78 RW2-4809D (H2/H3) 36 - 72 ±9 ±111 81 RW2-4812D (H2/H3) 36 - 72 ±12 ±83 83 RW2-4815D (H2/H3) 36 - 72 ±15 ±67 83 Max Capacitive Load(1) 4700µF 1000µF 1000µF 1000µF 4700µF 1000µF 1000µF 1000µF 4700µF 1000µF 1000µF 1000µF 4700µF 1000µF 1000µF 1000µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF ±680µF Standard Isolation is 1kVDC. Add suffix “/H2” for 2kVDC Isolation, “/H3” for 3kVDC Isolation. Add no suffix for standard case style, “/SMD” for SMD package or “/B” for smaller case size e.g. RW2-0505S/H3, RW2-0505D/H2/SMD or RW2-0505S/B Notes Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1second without damage to the converter Note 2: The RW2 series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions will not damage these devices; however, they may not meet all listed specifications. www.recom-power.com REV: 0/2015 RoHS 2011/65/EU 6/6 EN-60950-1 Certified (All Suffixes) EN-60601-1 Certified* (*/H suffix) RW2 Derating-Graph (Ambient Temperature) 100 Output Power (%) Part Number 80 60 40 Safe Operating Area 20 0 95 85 Operating Temperature °C -40 0 50 150 Refer to Application Notes E-129 RW2 Series ECONOLINE DC/DC-Converter Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified) Input Voltage Range Output Accuracy Line Voltage Regulation Load Voltage Regulation Minimum Load Output Ripple and Noise (20MHz limited) Switching Frequency (at full Load) Efficiency at Full Load Isolation Voltage (20% to 100% full load) (tested for 1 second) (rated for 1 minute*) (tested for 1 second) (rated for 1 minute*) (tested for 1 second) (rated for 1 minute*) H2-Suffix H3-Suffix Isolation Capacitance Isolation Resistance Short Circuit Protection Operating Temperature Range Storage Temperature Range Case Temperature Relative Humidity Package Weight Packing Quantity MTBF (+25°C) (+85°C) } 2:1 ±2% typ. ±0.5% max. ±0.5% typ. 10% (2) 50mVp-p max. 100kHz min. / 700kHz max. 70% min. / 80% typ. 1000VDC 500VAC / 60Hz 2000VDC 1000VAC / 60Hz 3000VDC 1500VAC / 60Hz 30pF max. 1GΩ min. Continuous –40°C to +85°C (see Graph) –55°C to +125°C 100°C max. 95% RH 6.4g 20 pcs per tube 22 pcs per Tube 4366 x10³ hours 658 x10³ hours Case Style A, SMD Case Style B using MIL-HDBK 217F using MIL-HDBK 217F For Detailed Information see Application Notes chapter "MTBF" **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. RW2 Package Style and Pinning (mm) 15.24 Case Style A 2.54 2.54 1.00 dia. 7 8 2.54 16 Pin DIP Package Recommended Footprint Details 10.20 2.54 18.55 2.54 0.50 Pin area 0.1 x 0.50 1.54 2.03 7 8 1 Bottom View 17.24 10 9 16 Top View 19.27 Top View Recommended Footprint Details Pin Connections (All Case Styles) 9.70 SMD Case Style 2.54 16 Pin Mini-DIP Package 14.50 24.2 10.16 10 9 7 x 2.54 Top View 2.54 1.00 dia. Bottom View 16 7 x 2.54 10.16 7 8 1 12.55 10 9 2.54 Case Style B Bottom View 16 6.0 15.24 16.9 ±0.2 0.50 1 14.50 4.00 8.50 4.60 9.70 12.55 22.1 14.50 24.2 1 Pin # Single Dual 1 7 8 9 10 16 –Vin NC NC +Vout –Vout +Vin –Vin NC Com +Vout –Vout +Vin Certifications EN General Safety Report: SPCLVD1212007 7 x 2.54 17.78 16 Pin SMD Package Recommended Pad Details XX.X ± 0.5 mm XX.XX ± 0.35 mm EN60950-1:2006 + A12:2011 EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-130 REV: 0/2015 www.recom-power.com