RUM - recom

●
●
●
●
●
●
●
●
Features
Unregulated
Converters
Twin Independent Outputs
Output/Output Isolation 1kVDC
Power Sharing on Outputs
Input/Output Isolation 1kVDC
Standard and Miniature Versions
Optional Continuous Short Circuit Protected
Custom Solutions Available
Efficiency to 76%
ECONOLINE
DC/DC-Converter
with 3 year Warranty
The RU DC/DC converter offers two independent isolated outputs. Typical applications include
multiple channel circuits where inter-channel isolation is also required. The RUM offers
similar specifications in a miniature case for applications where space is at a premium. Both
converters offer 1KVDC input/output isolation and 1kVDC output/output isolation.
The /H versions offer 2kVDC isolation between input and outputs.
Description
1 Watt
SIP7
Isolated
Dual Output
Selection Guide
Part
Number
SIP 7
2kV
Input
Voltage
(VDC)
Output
Voltage
(V1VDC)
Output
Voltage
(V2VDC)
Output
Current
(mA)
Efficiency
typ.
(%)
Max
Capacitive
Load(1)
RU-3.30505
(H)
3.3
5
5
100/100
76
470µF/470µF
RU-050505
(H)
5
5
5
100/100
72
470µF/470µF
3.3
5
5
100/100
78
470µF/470µF
RUM-050505 (H)
5
5
5
100/100
Other input and output voltage combinations available on request
* add Suffix “P” for Continuous Short Circuit Protection,
e.g. RU-050505/P, RUM-050505/P, RU-3.30505/HP
72
470µF/470µF
RUM-3.30505 (H)
RoHS
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10%~100% Load)
Output Ripple and Noise (20MHz limited)
Full Load
Operating Frequency
Efficiency at Full Load
}
www.recom-power.com
REV: 0/2015
EN-60950-1 Certified
RU/RUM
Derating-Graph
(Ambient Temperature)
100
80
Output Power (%)
±10%
±5%
1.2%/1% of Vin typ.
15% max
10% typ.
RU
75mVp-p max.
RUM
100mVp-p max.
20kHz min. / 70kHz typ. / 105kHz max.
RU
70% min.
RUM
70% min.
Minimum Load = 0%
Specifications valid for 10% minimum load only.
Isolation Voltage
(tested for 1 second)
1000VDC
Input/Output and Output/Output
(rated for 1 minute**)
500VAC / 60Hz
Isolation Voltage
H-suffix
(tested for 1 second)
2000VDC
Input/Output
H-suffix
(rated for 1 minute**)
1000VAC / 60Hz
Output/Output
H-suffix
(rated for 1 minute**)
500VAC / 60Hz
Isolation Capacitance
20pF min. / 94pF max.
Isolation Resistance
10 GΩ min.
Short Circuit Protection
1 Second
P-Suffix
Continuous
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Package Weight
2.7g
Packing Quantity
RU
25 pcs per Tube
RUM
30 pcs per Tube
MTBF (+25°C) Detailed Information see
using MIL-HDBK 217F
1012 x 103 hours
Application Notes chapter "MTBF"
(+85°C)
using MIL-HDBK 217F
151 x 103 hours
Certifications
EN60950-1
Report: SPCLVD1109103
EN60950-1: 2006+A12:2011
2011/65/EU
6/6
60
40
30
20
0
Safe Operating Area
-40
0
50
85
Operating Temperature °C
100
150
**Any data referred to in this datasheet are of indicative nature and based
on our practical experience only. For further details, please refer to our
Application Notes.
Refer to Application Notes
E-79
RU/ RUM
Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
Deviation / Load
Efficiency / Load
100
25.000
20.000
Deviation from Nominal (%)
80
60
RU-050505
RUM-050505
Efficiency %
40
20
0
0% 20%
40%
60%
Total Output current (%)
100%
80%
15.000
10.000
5.000
0.000
-5.000
-10.000
0% 20%
40%
60%
Total Output current (%)
80%
100%
Notes
Note 1
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
RU Package Style and Pinning (mm)
6.00
SIP7 Package
10.20
RECOM
RU-050505
****
RECOM
RU-050505
****
0.51 typ.
1 2
0.51 typ.
4.10
4 5 6 7
Pin Connections
Recommended Footprint Details
1.27
RU/RUM
2.0
Bottom View
Pin #
1.00 ø+0.15/–0
19.60
2.54
0.25
15.24
Top View
2.54
Single
1
+Vin
2
–Vin
4
+Vout 1
5
–Vout 1
6
+Vout 2
7
–Vout 2
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
RUM Package Style and Pinning (mm)
SIP6 Package
6.00
7.70
RECOM
RUM-0505S
****
RECOM
RUM-0505O5
****
0.51 typ.
1 2 3 4 5 6
0.51 typ.
4.10
Pin Connections
Recommended Footprint Details
1.27
Bottom View
1.9
12.70
1
1.00 ø+0.15/–0
16.55
2.54
0.25
2.54
Pin #
Top View
Single
+Vin
2
–Vin
3
-Vout 1
4
+Vout 1
5
-Vout 2
6
+Vout 2
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Typical Application
Fuse
DC1
DC
Channel 1
DC2
Channel 2
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-80
REV: 0/2015
www.recom-power.com