REC3-S_DRW(Z) - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
●
●
●
2kV, 4kVDC & 6kVDC Isolation
Industry Standard 3W DIP24 Package
Feedback Regulated Output
Continuous Short Circuit Protection
Wide Input 2:1 & 4:1
Medical Approvals (4kV/6kV Versions)
EN and UL Certificates
3 Pinout Options, 3 Case Styles
Control Pin Option
Efficiency to 86%
Description Besides the standard isolation of 2kVDC, this series offers options of 4kVDC (= "/H4") or 6kVDC
(="/H6") making it suitable for medical applications and other sophisticated industrial applications. Packaging can be either DIP-24 plastic or 5-side-shielded DIP24 metal case (=option
"/M") as well as SMD pinning (= option "/SMD"). For all the above variants, 2 industry-standard
pinouts (= option "/A" or "/C") are available, and B pinning is available with 1.6kVDC isolation.
Remote on/off control is possible with the /CTRL option (A pinning only). The converters can
deliver 140% rated power for short periods of time to cope with applications with large
capacitive loads or high start up currents.
ECONOLINE
DC/DC-Converter
with 3 year Warranty
3 Watt
DIP24 & SMD
Single & Dual
Output
Selection Guide
Part
Number
DIP24 (SMD)
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output Efficiency
Max
Current
Capacitive
(mA)
(%)
Load(1)
REC3-xx3.3SRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
3.3
900
66-76
4700µF
REC3-xx05SRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
5
600
71-79
4700µF
REC3-xx09SRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
9
330
74-83
3300µF
REC3-xx12SRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
12
250
75-85
2200µF
REC3-xx15SRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
15
200
75-86
2200µF
REC3-xx05DRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
±5
±300
74-83
±2200µF
REC3-xx12DRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
±12
±125
75-85
±1000µF
REC3-xx15DRW/H*
4.5 - 9, 9 - 18, 18 - 36, 36 - 72
±15
±100
75-86
±1000µF
REC3-xx3.3SRWZ/H*
9 - 36, 18 - 72
3.3
900
77-79
4700µF
REC3-xx05SRWZ/H*
9 - 36, 18 - 72
5
600
78-80
4700µF
REC3-xx09SRWZ/H*
9 - 36, 18 - 72
9
330
80-83
3300µF
REC3-xx12SRWZ/H*
9 - 36, 18 - 72
12
250
83-85
2200µF
REC3-xx15SRWZ/H*
9 - 36, 18 - 72
15
200
83-85
2200µF
REC3-xx05DRWZ/H*
9 - 36, 18 - 72
±5
±300
77-80
±2200µF
REC3-xx12DRWZ/H*
9 - 36, 18 - 72
±12
±125
83-85
±1000µF
REC3-xx15DRWZ/H*
9 - 36, 18 - 72
±15
±100
83-85
±1000µF
H* = H2, H4 or H6 for A or C pinning options with 2kVDC, 4kVDC or 6kVDC isolation.
RoHS
2011/65/EU
6/6
E-358085
EN-60950-1 Certified
UL-60950-1 Certified
EN-60601-1 Certified
REC3-S_DRW
Isolation Restrictions
‘B” Pinning is restricted to 1.6kV isolation due
to the closeness of the input and output pins.
H* = H for B pinning option with 1.6kVDC isolation only.
2:1 Input
(REC3-S/DRWH4/H6)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
4:1 Input
(REC3-S/DRWZ(H4/H6))
xx = 9-36Vin = 24
xx = 18-72Vin = 48
* add suffix "/A", "/A/X2", "/B"or "/C" for pinning options,
see next page and Isolation Restrictions.
* add suffix "/M" for metal case.
* add suffix "/SMD" for SMD package.
* add suffix "/CTRL" for control pin option
(A Pinning only)
* add suffix -R for Tape and Reel packaging
Ordering Examples:
REC3-0512DRW/H2/A/CTRL= 2:1 input, 5V Vin, ±12V Vout, 2kVDC, pinout “A”, plastic case, control pin
REC3-4812SRWZ/H4/A/M = 4:1 input, 48V Vin, 12V Vout, 4kVDC, pinout “A”, metal case, no control pin
REC3-2412DRWZ/H/B = 4:1 input, 24V Vin, ±12V Vout, 1.6kVDC, pinout “B”, plastic case, no control pin
REC3-0505SRW/H6/C/SMD-R = 2:1 input, 5V Vin, 5V Vout, 6kVDC, SMD pinout “C”, plastic case,
no control pin, Tape and Reel packaging.
www.recom-power.com
REV: 0/2015
If the options "/M" for metal case and "/SMD"
for SMD pinout are combined, the maximum
allowed isolation voltage is 2kVDC because of
the shorter distances between pins and the
metal case.
DIP-24 through-hole case and SMD-plastic
case are not affected and offer the full isolation
barriers of 2kV through to 6kVDC.
Refer to Application Notes
E-141
REC3-S_DRW(Z)
/H* Series
ECONOLINE
DC/DC-Converter
Input Voltage Range
2:1 & 4:1
Output Voltage Accuracy
±2% max.
Line Regulation (HL-LL)
±0.4% max.
Load Regulation (for output load current change from 20% to 100%)
±0.6% max.
Minimum Load
10% (2)
Output Ripple and Noise (0,1µF capacitor on output, 20MHz BW)
50mVp-p max.
Switching Frequency at Full Load
2:1 Input types
90kHz min. / 150kHz max.
and nominal Input Voltage
4:1 Input types
120kHz min. / 180kHz max.
Input Filter
Pi Network
Efficiency at Full Load
see above
No Load Power Consumption
300mW max.
Isolation Voltage
H2-Suffix
(tested for 1 second)
2000VDC
(rated for 1 minute**)
1000VAC / 60Hz
Isolation Voltage
H4-Suffix
(tested for 1 second)
4000VDC
(rated for 1 minute**)
2000VAC / 60Hz
Isolation Voltage
H6-Suffix
(tested for 1 second)
6000VDC
(rated for 1 minute**)
3000VAC / 60Hz
Isolation Capacitance
2:1 Input types
20pF min. / 60pF max.
4:1 Input types
40pF min. / 80pF max.
Isolation Resistance
1 GΩ min.
Short Circuit Protection (Max temp. = 60°C during short circuit conditions)
Continuous, Auto Restart
Operating Temperature Range
5V input types
-40°C to +80°C (see Graph)
(free air convection)
others
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
95% RH
Case Material
Non-Conductive Plastic or Metal
Thermal Impedance
Natural convection
20°C/W for plastic case
12°C/W for metal case
Package Weight
13g
Packing Quantity
15 pcs per Tube
100 pcs per Reel
MTBF (+25°C)
using MIL-HDBK 217F
1043 x 103 hours
}
Derating-Graph
(Ambient Temperature)
Output Power (%)
Output Power (%)
Vin = 5V
120
100
80
60
50
40
20
0
-40
Safe Operating Area
100
50 75
125
80 105
Operating Temperature (°C)
120
100
80
60
50
40
20
0
-40
0
25
Safe Operating Area
0
25
50 75
Operating Temperature (°C)
100
85 105
125
Detailed Information see
Application Notes chapter "MTBF"
186 x 103 hours
UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
EN General Safety Report: SPCLVD1212007 EN60950-1:2006 + A1:2010+A12:2011
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Ed.
Medical Report + ISO14971 Risk Assessment
(+85°C)
using MIL-HDBK 217F
Certifications UL General Safety Report: E358085
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please
refer to our Application Notes.
Notes
Note 1:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2:
The REC3-RW series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load
conditions will not damage these devices; however, they may not meet all listed specifications.
Typical Characteristics
Single 2:1 Input Single 2:1 Input
100
2415
2409
60
Efficiency %
40
20
0%
40%
20%
60%
Total Output current (%)
E-142
80%
100%
20
0
0512D
1212D
60
60
2405
40
80
80
80
0
Efficiency / Load
100
2418
1205
2424
4805
0%
40%
20%
60%
Total Output current (%)
80%
REV: 0/2015
100%
0515D
40
Efficiency %
100
Dual 2:1 Input
Efficiency / Load
Efficiency / Load
Efficiency %
REC3-RW
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
20
0
0%
40%
20%
60%
Total Output current (%)
80%
100%
www.recom-power.com
REC3-S_DRW(Z)
/H* Series
ECONOLINE
DC/DC-Converter
Typical Characteristics - Continued
Single 4:1 Input Single 4:1 Input
Efficiency / Load
100
60
40
0%
40%
20%
60%
Total Output current (%)
80%
20
0
100%
2415D/
H4
40
483.3/
H4
Efficiency %
20
Efficiency %
243.3/
H4
2412D/
H4
80
60
40
Efficiency %
100
4805/
H4
80
60
0
Efficiency / Load
Efficiency / Load
100
2405/
H4
80
Dual 4:1 Input
0%
40%
20%
60%
Total Output current (%)
100%
80%
20
0
0%
40%
20%
60%
Total Output current (%)
80%
100%
Package Style and Pinning (mm) DIP 24 , Wide Input 2:1 & 4:1
“A” Pinning
20.30
32.00
/H2, /H4 & /H6
Pin Connections
10.20
Pin #
3.8+0.5 /-0.25
15.24
0.51
4.60
CTRL Option
only
1 2 3
9
Recommended Footprint Details
1.00 ø+0.15/–0
11
23 22
16
Vin+
CTRL Option
3.8+0.5 /-0.25
15.24
Recommended Footprint Details
1.00 ø+0.15/–0
1 2
10 11 12
15
2.54
13
2.54
www.recom-power.com
–Vin
9
NC
No Pin
Com
11
NC
NC
–Vout
14
+Vout
+Vout
+Vout
16
–Vout
–Vout
Com
22
+Vin
+Vin
+Vin
23
+Vin
+Vin
+Vin
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin #
Single
Dual
1
+Vin
+Vin
2
+Vin
+Vin
10
NC
Com
11
NC
Com
12
–Vout
NC
13
+Vout
–Vout
15
NC
+Vout
23
–Vin
–Vin
24
–Vin
–Vin
NC = No Connection
Bottom View
24 23
–Vin
–Vin
Pin Connections
10.20
0.51
–Vin
–Vin
CTRL
1
1kW
1N4148
20.30
2.06
–Vin
3
RECx-xxxx/CTRL
2,3
Off
On
TTL Input
/H2, /H4 & /H6
2
22,23
0V
ON = Open or 0V< Vctrl <1.2V
OFF = 2.2V< Vctrl <12V
32.00
CTRL
Top View
2.54
“C” Pinning
Dual
CTRL
NC = No Connection
2.54
14
Single/X2
CTRL
REV: 0/2015
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Top View
E-143
REC3-RW
Bottom View
Single
1 (option)
REC3-S_DRW(Z)
/H* Series
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm) DIP 24 , Wide Input 2:1 & 4:1
“B” Pinning
32.00
20.30
Pin Connections
/H (1.6kV Only)
10.20
3.8+0.5 /-0.25
15.24
0.51
2.06
Recommended Footprint Details
1.00 ø+0.15/–0
1 2 3
10 11 12
Bottom View
24 23 22
2.54
15 14 13
Top View
2.54
Pin #
Single
1
+Vin
Dual
+Vin
2
No Pin
–Vout
Com
3
No Pin
10
–Vout
Com
11
+Vout
+Vout
12
–Vin
–Vin
13
–Vin
–Vin
14
+Vout
+Vout
15
–Vout
Com
22
No Pin
Com
23
No Pin
–Vout
24
+Vin
+Vin
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
32.00
19.90
31.40
SMD Pinning
11.20
10.90
3.81
2.54
SMD pin connections follow
standard package A (/A/SMD),
B (/B/SMD) or C (/C/SMD) pinning.
20.30
6.35
25.40
REC3-RW
Tol.: ± 0.35 mm
Recommended Footprint Details
Pin area
0.1 x 0.50
2.54
0.50
1.54
2.03
9 10 11 12
1 2 3 4 5
23.40
All unused pins are NC
(No Connection). See Below for
detailed pinout lists
26.67
Bottom View
Top View
24.64
16 15 14 13
24 23 22 21 20
1
27.94
11 x 2.54
for all packages incl.SMD case the length of plastic case is 31,8 mm, length of metal case 32.0 mm
/A/SMD Pinning
Pin Connections
Pin #
/B/SMD Pinning
Pin Connections
Single
Dual Pin #
Single
1 (Option)
CTRL
CTRL 13
2
–Vin
3
–Vin
Pin Connections
Dual
Pin #
NC
NC
–Vin 14
+Vout
–Vin 15
NC
/C/SMD Pinning
Pin Connections
Single
Dual Pin #
1
+Vin
+Vin 13
+Vout
2
NC
NC
3
NC
Single
Pin Connections
Single
Pin Connections
Dual
Pin #
Dual Pin #
-Vin
-Vin
1
+Vin
+Vin
13
+Vout
Single
Dual
–Vout 14
+Vout
+Vout
2
+Vin
+Vin
14
NC
NC
Com
15
-Vout
Com
3
NC
NC
15
NC
+Vout
-Vout
4
NC
NC
16
-Vout
Com
4
NC
NC
16
NC
NC
4
NC
NC
16
NC
NC
5
NC
NC
20
NC
NC
5
NC
NC
20
NC
NC
5
NC
NC
20
NC
NC
9
NC
Com 21
NC
NC
9
NC
NC
21
NC
NC
9
NC
NC
21
NC
NC
10
NC
NC
22
+Vin
+Vin
10
-Vout
Com
22
NC
Com
10
NC
Com
22
NC
NC
11
NC
-Vout 23
+Vin
+Vin
11
+Vout
+Vout 23
NC
-Vout
11
NC
Com
23
-Vin
-Vin
12
NC
NC
NC
12
-Vin
+Vin
+Vin
12
-Vout
NC
24
-Vin
-Vin
NC
24
-Vin
24
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-144
REV: 0/2015
www.recom-power.com