RS-S_D(Z) - Recom International Power Gmbh

Features
Regulated
Converters
●
●
●
●
●
●
●
ECONOLINE
2:1 and 4:1 Wide Input Voltage Ranges
1kVDC, 2kVDC & 3kVDC Isolation
UL94V-0 Package Material
Continuous Short Circuit Protection
Low Noise
No External Capacitor needed
Efficiency to 83 %
DC/DC-Converter
with 3 year Warranty
Description High power-density, an industrial temperature range of -40°C to +85°C and extra features
2 Watt
SIP8 Isolated
Single & Dual
Output
like Remote-On-Off- control are just some of the characteristics of this converter, ideal for
highly sophisticated industrial designs. The RS series is available with isolation of 2kV or 3kV
by choosing option "/H2" or "/H3" in which case it is also ideal for medical applications which
additionally require EN-60601-1 certification.
Selection Guide 5V, 12V, 24V and 48V Input Types
Input
Rated Output Output Current
Voltage Range
Voltage
at Full Load
SIP8
(VDC)
(VDC)
(mA)
RS-xx3.3S (H2/H3)
4.5-9, 9-18
3.3
500
18-36, 36-72
RS-xx05S (H2/H3)
4.5-9, 9-18
5
400
18-36, 36-72
RS-xx09S (H2/H3)
4.5-9, 9-18
9
222
18-36, 36-72
RS-xx12S (H2/H3)
4.5-9, 9-18
12
166
18-36, 36-72
RS-xx15S (H2/H3)
4.5-9, 9-18
15
134
18-36, 36-72
RS-xx3.3D (H2/H3)
4.5-9, 9-18
±3.3
±250
18-36, 36-72
RS-xx05D (H2/H3)
4.5-9, 9-18
±5
±200
18-36, 36-72
RS-xx09D (H2/H3)
4.5-9, 9-18
±9
±111
18-36, 36-72
RS-xx12D (H2/H3)
4.5-9, 9-18
±12
±83
18-36, 36-72
RS-xx15D (H2/H3)
4.5-9, 9-18
±15
±67
18-36, 36-72
RS-xx3.3SZ (H2/H3)
9-36
3.3
500
18-72
RS-xx05SZ (H2/H3)
9-36
5
400
18-72
RS-xx09SZ (H2/H3)
9-36
9
222
18-72
RS-xx12SZ (H2/H3)
9-36
12
166
18-72
RS-xx15SZ (H2/H3)
9-36
15
134
18-72
RS-xx3.3DZ (H2/H3)
9-36
±3.3
±250
18-72
RS-xx05DZ (H2/H3)
9-36
±5
±200
18-72
RS-xx09DZ (H2/H3)
9-36
±9
±111
18-72
RS-xx12DZ (H2/H3)
9-36
±12
±83
18-72
RS-xx15DZ (H2/H3)
9-36
±15
±67
18-72
Efficiency
typ.
(%)
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
75
75
80
80
80
80
83
83
84
84
73
73
77
77
80
80
81
81
83
83
No suffix is standard isolation (1kVDC) e.g, RS-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS-0505S/H2, RS-0505DZ/H3
E-126
REV: 0/2015
Max
Capacitive
Load
4700µF
1000µF
1000µF
1000µF
1000µF
RoHS
2011/65/EU
6/6
±2200µF
EN-60950-1 Certified
EN-60601-1 Certified*
±680µF
(*/H suffix )
±680µF
RS
±680µF
±680µF
4700µF
Derating-Graph
1000µF
(Ambient Temperature)
1000µF
RS-S(Z)_D(Z)
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
100
Output Power (%)
Part Number
4:1
80
60
40
30
20
0
2:1
Safe Operating Area
-40
0
50 7585 100
Operating Temperature °C
2:1 Input
(RS-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
150
4:1 Input
(RS-SZ/DZ)
xx = 9-36Vin = 24
xx = 18-72Vin = 48
Refer to Application Notes
www.recom-power.com
RS-S_D(Z)
Series
ECONOLINE
DC/DC-Converter
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified)
Input Voltage Range
2:1 and 4:1
Output Accuracy
±2% typ.
Line Voltage Regulation
±0.5% max.
Load Voltage Regulation
20%-100% Load
±0.5% max.
10% (2)
Minimum Load
Output Ripple and Noise (20MHz limited)
50mVp-p max.
Switching Frequency
Full Load
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
Isolation Voltage
Standard
/H2 Version
/H3 Version
Isolation Capacitance
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
100kHz min. / 300kHz max.
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max
RS-05xxS_D
RS-12xxS_D
RS-24xxS_D, SZ_DZ
RS-48xxS_D, SZ_DZ
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
Isolation Resistance
1GΩ min.
Short Circuit Protection
Operating Temperature Range
(No Derating)
Continuous
–40°C to +85°C
–40°C to +75°C
2:1
4:1
–55°C to +125°C
Relative Humidity
95% RH
Package Weight
4.7g
Packing Quantity
22 pcs per Tube
MTBF (+25°C)
(+85°C)
}
Detailed Information see
Application Notes chapter "MTBF"
Certifications
using MIL-HDBK 217F
1398 x 103 hours
using MIL-HDBK 217F
210 x 103 hours
EN General Safety
Report: SPCLVD1212007
EN60950-1:2006 + 11:2009+A1:2010+A12:2011
EN Medical Safety
Report: MDD1205098-3 + RM1205098-3
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2:
The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
www.recom-power.com
REV: 0/2015
E-127
RS
Storage Temperature Range
RS-S_D(Z)
Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
RS-24xx
RS-05xx types
Efficiency / Load
100
2412
80
2
1.70
1.5
2409
60
Efficiency %
2415
20
0
Output Power (W)
2405
40
0%
40%
20%
80%
60%
1
0.5
0
100%
4.5 5
7
6
9
8
Input Voltage (V)
Total Output current (%)
Package Style and Pinning (mm)
8 PIN SIP Package
11.10
4.1
9.20
RECOM
RS-xxxxS_D
****
0.50±0.05
Single Output
Dual Output
RECOM
RS-xxxxS
****
RECOM
RS-xxxxD
****
1 2 3
0.50±0.05
1 2 3
5 6 7 8
5 6 7 8
Pin Connections
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Recommended Footprint Details
21.80
0.32
1.0ø+0.15/–0
2.54
Bottom View
3.20
2.0
Top View
RS
2.54
Pin #
Single
1
–Vin
Dual
–Vin
2
+Vin
+Vin
3
CTRL
CTRL
5
NC
NC
6
+Vout
+Vout
7
–Vout
Com
8
NC*
–Vout
NC = No Connection
NC* = NC, but no external Connection allowed.
Pin 8 (NC*) This pin is used internally and must have no external connection.
Pin 5 (NC) Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is ON.
There is no allowed low state for this pin.
Application Examples
ON/OFF CONTROL
V+
+Vin
+Vout
VIN+
ON
LEAVE OPEN
3
CTRL
OFF
5~12
VIN-
1N4148
68 Ω
CTRL
-Vin
10K
-Vout
FET.
V-
I = 3V
O = 0.5V or GND
Remote ON/OFF
ON: open or high impendance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-128
REV: 0/2015
www.recom-power.com