RAC40-TB - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
●
Compact 40W AC-DC Power Supply
Universal Input Voltage Range
3000VAC Isolation
Low Output Ripple and Noise
Short Circuit Protected
Triple Output with Independent Outputs
Suitable for Industrial Applications
CE Marked
POWERLINE
AC/DC-Converter
with 3 year Warranty
Compact switching power module for PCB or DIN-rail mounting
Description
40 Watt
Single/Dual/
Double &
Triple Output
Selection Guide
Part
Number
Input
Range
(VAC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(%)
Max.
Capacitive
Load
RAC40-05SB
90-264
5
8000
81
40000µF
RAC40-12SB
90-264
12
3333
84
8600µF
RAC40-15SB
90-264
15
2666
83
6600µF
RAC40-24SB
90-264
24
1667
83
1400µF
RAC40-05DB
90-264
±5
±4000
81
±12000µF
RAC40-12DB
90-264
±12
±1666
83
±4400µF
RAC40-15DB
90-264
±15
±1333
83
±1000µF
RAC40-0512DB
90-264
5/12
5000/1250
82
10000/470µF
RAC40-0512TB
90-264
5/±12
+5000/±600
82
10000/±780µF
RAC40-0515TB
90-264
5/±15
+5000/±500
81
10000/±900µF
RoHS
*add suffix "-ST” for screw terminal module e.g. RAC40-05SB-ST, RAC40-05DB-ST, RAC40-0512TB-ST
2011/65/EU
6/6
Specifications (typical at 25°C and after warm up time unless otherwise specified )
www.recom-power.com
REV: 0/2015
RAC40-B
Derating-Graph
(Ambient Temperature)
125
100
Output Power (%)
Input Voltage Range
90-264VAC or 100-375VDC
Rated Power
40 Watts max.
Input Frequency Range (for AC Input)
47-440Hz
Input Current (full load)
115VAC/230VAC
860mA/ 460mA max.
No Load Power Consumption
115VAC/230VAC
720mW max.
Inrush Current (<2ms)
115VAC/230VAC
30A / 50A max.
Leakage Current
0.75mA max.
Holdup time
10ms min.
Output Voltage Accuracy (Full load) (2)
Single, Dual Outputs ±2% typ.
Double/Triple: Main Output ±3% typ., Secondary Output(s) ±5% typ.
Line Voltage Regulation (low line, high line at full load )
Single, Dual Outputs ±0.5% typ.
Double/Triple: Main Output ±0.5% typ., Secondary Output(s) ±5% typ.
Load Voltage Regulation
(1% to 100% Load)
Single: ±1% typ.
(10% to 100% Load)
Dual: Main Output ±1% typ., Secondary Output ±1% typ.
(10% to 100% Load)
Double: Main Output ±2% typ., Secondary Output ±6% typ.
(10% to 100% Load)
Triple: Main Output ±3% typ., Secondary Outputs ±7% typ.
Cross Regulation
Dual: Main Output ±5%, Secondary Output ±5% typ.
Double: Main Output ±1% typ., Secondary Output ±7% typ.
Triple: Main output ±3% typ., Secondary Outputs ±7% typ.
Output Ripple and Noise (20MHz limited, 0.1µF and 47µF across outputs)
1% Vout max.
Operating Frequency
132kHz typ.
RMS Isolation Voltage (input to output)
3kVAC / 1 minute
Temperature Coefficient
±0.01%/°C typ.
Isolation Resistance
100 MΩ min.
Short Circuit Protection
Continuous, Automatic Restart
Overcurrent Protection
105% typ.
Over Temperature Protection
100°C
Operating Temperature Range (free air convection, with derating)
-40°C to +70°C
Storage Temperature Range
-40°C to +85°C
continued on next page
75
40
50
Natural Convection
25
0
-40 -25 -10 0
30 40
50
60 70 80 90
Ambient Temperature Range (°C)
Refer to Application Notes
PA-51
RAC40-S_D_TB
Series
POWERLINE
AC/DC-Converter
Specifications (typical at 25°C and after warm up time unless otherwise specified )
Humidity
95% RH
Case Material
Package Weight
suffix (-ST)
Epoxy with Fibreglass (UL94V-0)
280g
300g
Packing Quantity
2 pcs (-ST Version: 1 pc)
EMC
EN 55022 Class B, EN55024
MTBF (+25°C)
200~400 x 103 hours
using MIL-HDBK-217F
Notes:
Note 1: Suggested input fuse rating 3.15A Slo Blo
Note 2: Triple output version has +/-Vout common that is not connected to +5V Return pin internally.
Screw Terminal Module Option (suffix -ST)
32.5
5.5
Pin Connections
Removable DIN-Rail
Mounting Bracket
Pin #
1
1
4
5
RAC40-xxS_D_TB
2
3
6
7
8
RAC40-B
Fuse
50.0
63.7
100.0
111.9
Single Out
Dual Out
Double Out
Triple Out
NC
NC
NC
NC
2
VAC in (L)
VAC in (L)
VAC in (L)
VAC in (L)
3
VAC in (N)
VAC in (N)
VAC in (N)
VAC in (N)
4
+VDC out
+VDC out
+12V Out
+VDC out
5
NC
NC
+5V Out
+5V Out
6
-VDC out
Com
+12V Rtn
Com
7
NC
NC
+5V Rtn
+5V Rtn
8
NC
-VDC out
NC
-VDC out
NC = No Connection
Package Style and Pinning
63.5
89.0
27.00
6.0
1.2
81.30
Pin Connections
2
7
15.24
6
12.7
55.88
Bottom View
5
12.7
4
15.24
1
3
Tolerance =± 0.5 mm
Pin #
Single Out
Dual Out
Double Out
Triple Out
1
VAC in (L)
VAC in (L)
VAC in (L)
VAC in (L)
2
VAC in (N)
VAC in (N)
VAC in (N)
VAC in (N)
3
+VDC out
+VDC out
+12V Out
+VDC out
4
No Pin
No Pin
+5V Out
+5V Out
5
-VDC out
Com
+12V Rtn
Vout Com
6
No Pin
No Pin
+5V Rtn
+5V Rtn
7
NC
-VDC out
No Pin
-VDC out
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.