RAC15-A - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
POWERLINE
Compact AC-DC Power Supply
15 Watt PCB Mount Package
Universal Input Voltage Range
3000VAC Isolation
Low Output Ripple and Noise
Short Circuit Protected
UL Certified, CE Marked
AC/DC-Converter
with 3 year Warranty
Compact UL certified switching AC/DC power module for PCB, screwterminal connection or DIN-rail mounting.
Description
15 Watt
Single/Dual
& Triple
Output
Selection Guide
Part
Number
Output
Voltage
(VDC)
5
Output
Current
(mA)
3000
Efficiency
RAC15-05SA
Input
Range
(VAC)
90-264
(%)
74
Max.
Capacitive
Load
31000µF
RAC15-12SA
90-264
12
1250
79
4500µF
RAC15-15SA
90-264
15
1000
78
2700µF
RAC15-24SA
90-264
24
625
80
900µF
RAC15-05DA
90-264
±5
±1500
76
±13500µF
RAC15-12DA
90-264
±12
±650
79
±2700µF
RAC15-15DA
90-264
±15
±500
77
±1400µF
RAC15-0512TA
90-264
5/±12
2000/±200
73
14000/±900µF
RAC15-0515TA
90-264
5/±15
2000/±150
73
14000/±680µF
*add suffix “-E” for extended temperature range, e.g. RAC15-05SA-E
*add suffix "-ST” for screw terminal module e.g. RAC15-05DA-ST, RAC10-0512TA-E-ST
RoHS
2011/65/EU
6/6
Specifications (typical at 25°C and after warm up time unless otherwise specified )
Leakage Current
Output Voltage Accuracy (Full load)
Line Voltage Regul. (low line, high line at full load)
Load Voltage Regulation (5% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
RMS Isolation Voltage (input to output)
Temperature Coefficient
Isolation Resistance
Short Circuit Protection
Operating Temperature Range *
(free air convection, with derating)
Storage Temperature Range
Humidity
Case Material
Package Weight
Packing Quantity
EMC
MTBF (+25°C)
90-264VAC or 120-370VDC
15 Watts max.
47-440Hz
115VAC/230VAC
310mA / 170mA max.
115VAC/230VAC
1.37W max.
115VAC
10A max. (-E = 23A max.)
230VAC
20A max. (-E = 46A max.)
0.75mA max.
±2%
Single, Dual
±0.5% typ.
Triple
±1%/±5% typ.
Single
±0.5% typ.
Dual
±3% typ.
Triple
±2%/±5% typ.
Noise
0.5% Vout + 50mVp-p max.
Ripple
<0.2% Vout + 40mVp-p max.
100kHz typ.
see table
3kVAC / 1minute
±0.02%/°C typ.
100 MΩ max.
Hiccup, Automatic Restart
Standard
-25°C to +70°C
Suffix -E
-40°C to +70°C
-40°C to +85°C
95% RH max.
Epoxy with Fibreglass (UL94V-0)
114g
3 pcs (-ST Version: 1 pc)
EN 55022 Class B / EN 55024
using MIL-HDBK-217F
200 x 103 hours
E196683
UL-60950-1 Certified
RAC15-A
Derating-Graph
(Ambient Temperature)
125
100
Output Power (%)
Input Voltage Range
Rated Power
Input Frequency Range (for AC Input)
Input Current (full load)
No Load Power Consumption
Inrush Current (<2ms)
E-Version
75
50
Natural Convection
25
0
-40 -25 -10 0
50
60 70 80 90
Ambient Temperature Range (°C)
Refer to Application Notes
* Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
www.recom-power.com
REV: 0/2015
PA-43
RAC15-S_D_TA
Series
POWERLINE
AC/DC-Converter
Screw Terminal Module Option (suffix -ST)
27.6
5.5
Removable DIN-Rail
Mounting Bracket
Pin Connections
Pin #
1
4
5
RAC15-xxS_D_TA
2
3
6
7
8
Fuse
50.0
63.7
100.0
111.9
Single Out
Dual Out
Triple Out
1
FG
FG
FG
2
VAC in (N)
VAC in (N)
VAC in (N)
3
VAC in (L)
VAC in (L)
VAC in (L)
4
NC
NC
-VDC Out
5
-VDC Out
-VDC Out
Com
6
NC
Com
+ VDC Out
7
+ VDC Out
+ VDC Out
+ 5V Rtn (Com)
8
NC
NC
+ 5V Out
NC = No Connection
Standard Package Style and Pinning
54.00
74.00
RAC15-A
22.00
8.0
1.0
62.00
3
Pin Connections
Pin #
8
27.0
20.0
8.5
7
11.5
2
Bottom View
6
11.5
20.0
5
1
8.5
4
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Single Out
Dual Out
Triple Out
1
FG
FG
FG
2
VAC in (N)
VAC in (N)
VAC in (N)
3
VAC in (L)
VAC in (L)
VAC in (L)
-VDC Out
4
No Pin
No Pin
5
-VDC Out
-VDC Out
Com
6
No Pin
Com
+ VDC Out
7
+ VDC Out
+ VDC Out
+ 5V Rtn (Com)
8
No Pin
No Pin
+ 5V Out
Standard Application Circuit
L
VACin (L)
Vout+
E
FG
(Com)
N
VACin (N)
Vout-
Suggested fuse rating
2A Slow Blow
Fuse
Load
Load
Load
Dual
Single
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-44
REV: 0/2015
www.recom-power.com