RAC03-SC - recom

Features
Regulated
Converters
●
●
●
●
●
●
●
●
●
Ultracompact Low Profile AC-DC Power Supply
3 Watt PCB Mount Package
Universal Input Voltage Range
Class II Power Supply with 3kVAC Isolation
Only 80mW Consumption in Standby
-25°C to +85°C Operating Temperature
Low Output Ripple/Noise
Short Circuit Protected Outputs
EN, UL and CE Certified
POWERLINE
AC/DC-Converter
with 3 year Warranty
3 Watt
Single
Output
The RAC03-SC series is an ultra-compact universal input AC/DC power
module for PCB mounting. It features high efficiency, low standby power,
high operating temperature, soft start, low output ripple/noise, overload
and short-circuit protection as well as a built-in EMC Class B filter. Output
voltages range from 3.3VDC to 24VDC, including a 3.8VDC version
designed for battery chargers and GSM modems.
Description
Selection Guide
Part
Number
Output
Voltage
(VDC)
3.3
Output
Current
(mA)
900
Efficiency
RAC03-3.3SC
Input
Range
(VAC)
80-264
(%)
67
Max
Capacitive
Load (1+2)
6800µF
RAC03-3.8SC
80-264
3.8
900
67
6800µF
RAC03-05SC
80-264
5
600
72
4000µF
RAC03-09SC
80-264
9
333
76
3000µF
RAC03-12SC
80-264
12
250
76
680µF
RAC03-15SC
80-264
15
200
76
470µF
RAC03-24SC
80-264
24
125
78
200µF
RoHS
2011/65/EU
6/6
Input Voltage Range (with derating)
80-264VAC or 115-370VDC
Rated Power
3 Watts max.
Input Frequency Range (for AC Input)
47-63Hz
Input Current (full load)
115/230VAC
85mA/40mA max.
No Load Power Consumption
80mW typ.
Inrush Current (<0.5ms)
115/230VAC
30/60A max.
Leakage Current
0.85mA max.
Output Voltage Tolerance (combined Tolerance, Line Reg and Load Reg at full load)
±5% max.
Line Voltage Regulation
low line, high line at full load
±3% max.
Load Voltage Regulation
10% to 100% full load
±6% max.
Output Ripple and Noise
3.3V, 3.8V, 5V Output
120mVp-p max.
(20MHz BW limited)
All others
150mVp-p max.
Operating Frequency @ full load
35kHz typ
Hold-up Time
115 VAC
15ms typ.
230VAC
80ms typ.
Minimum Load = 0%
specifications valid for 10% minimum load only
RMS Isolation Voltage
input to output
3kVAC / 1 minute
Isolation Resistance
input to output
1 GΩ min.
Isolation Capacitance
input to output
1000pF typ.
Short Circuit Protection
Hiccup, Automatic Restart
Over Voltage Category
OVC II
(natural convection, without derating)
-25°C to +75°C
Operating Temperature Range (3)
(natural convection, with derating)
-25°C to +85°C
Storage Temperature Range
-40°C to +100°C
Humidity
non-condensing
95% RH max
Case Material
Plastic Case, Silicon filled (UL94V-0)
Package Weight
30g
Packing Quantity
12 pcs
EMC
Conducted and Radiated
EN 55022 Class B
Noise Immunity
EN 55024
continued on next page
PA-6
REV: 0/2015
EN-60950-1 Certified
UL-60950-1 Certified
RAC03-SC
Derating-Graph
(Ambient Temperature)
125
Natural Convection
100
Output Power (%)
RAC03-C
Specifications (measured at TA 25°C, full load after warm-up)
E224736
75
50
25
0
-25
0
50 60 70 80 90 100
75 85
Ambient Temperature Range (°C)
Refer to Application Notes
www.recom-power.com
RAC03-SC
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
MTBF
230VAC
using MIL-HDBK-217F
Certifications:
UL General Safety
EN General Safety
CE
+25°C
+55°C
+80°C
>550 x 103 hours
>285 x 103 hours
>76 x 103 hours
File Nr. E224736
SPCLVD 1202026
Report: T110809202-E
UL-60950-1, 2nd Edition
EN-60950-1, 2nd Edition
EN55022 Class B
Notes:
Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contace RECOM for detailed information.
Note3: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
Input Voltage Derating Graph
RAC03-05SC
Efficiency / Load
Input Voltage Derating Graph
100
230VAC
Load (%)
Efficiency %
264V, 100%
115VAC
60
40
20
0
90V, 100%
100%
80
0%
20%
40%
80%
60%
Total Output current (%)
90%
80%
70%
100%
Safe Operating Area
80V, 85%
130
80
180
230
280
Input Voltage (VAC) Ta=25°C
Standard Package Style and Pinning
Pin Connections
23.90
37.80
16.40
+0.25
-
6.1
Standoff height
0.75+0.25
-
ø1.0
5.0
17.78
1.20 ø+0.2/–0.1
20.32
5.08
1
VAC in (L)
3
VAC in (N)
13
NC
14
-VDC out
16
+VDC out
NC = No Connection
5.08
3
Single Output
1
RAC03-SC
Pin #
15.65
13
Leave Clear
of
PCB Traces
Bottom View
16
Tolerance
± 0.5 mm
unless otherwise specified
14
2.54
Top View
2.54
Recommended Application Circuit
Compact single output regulated power supply
Suggested fuse rating: 1A Slow Blow
An external MOV is required for 230VAC operation. The varistor should comply with IEC-61051-2. e.g. Epcos S14 Series
L
1A Fuse
MOV
- required for
230VAC Surge
Protection only
N
Vout+
VACin (L)
C1(Optional)
330uF
RAC03-05SC
VACin (N)
Load
Vout-
Add C1 to reduce output ripple (use low ESR type)
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
PA-7