HRP 106 - Screening Guide for Hi-rel Hybrid Multiplier Assemblies

Appendix D: Screening Guides
HRP 106 : Hi-rel Hybrid Multiplier Assemblies
The following screening for multiplier assemblies is a guide for a suggested
up-screening procedure. It can be modified or adjusted to suit requirements for a hi-rel
hybrid multiplier application.
1)
Pre-pot Visual
MIL-STD-750
Method 2071
2)
High Temp Life
MIL-STD-750
Method 1032
24 hours @ TA =125°C
3)
Temperature Cycling
MIL-STD-750
Method 107
20 Cycles
-55°C to +105°C
15 minutes at extremes
15 minutes transition
4)
Pre-Electrical
Voltage - in per spec
Voltage - out per spec
Current - out per spec
Voltage ripple per spec
- as applicable
5)
Burn-in
48 hours @ TA =25°C
Voltage - out 100% Vrated
Current - no load
6)
Post Electrical
Voltage - in per spec
Voltage - out per spec
Current - out per spec
Voltage ripple per spec
14
295