i1 RECEIVER ASSEMBLY - Virginia Panel Corporation

4
3
1
THE INFORMATION CONTAINED HEREIN IS THE EXCLUSIVE PROPERTY OF VIRGINIA PANEL CORPORATION
AND IS SUBMITTEDFOR USE BY THE CUSTOMER ONLY. THE DATA SHALL NOT BE DUPLICATED, USED,
OR DISCLOSED IN WHOLE OR IN PART FOR ANY PURPOSE OTHER THAN TO MAINTAIN THE EQUIPMENT
PROVIDED. CONSULT WITH VIRGINIA PANEL CORPORATION ENGINEERING IF MORE DETAIL IS REQUIRED.
DO NOT SCALE DRAWING
5.33
.21
2
38.10
1.50
REVISIONS
DATE
11/9/12
DESCRIPTION
REV
B EC #4326
3.05
.12
D
77.72
3.06
D
63.11
2.48
71.63
2.820
C
C
46.99
1.85
4.45
.18
4X
RECOMMENDED LOCATION FOR
ATTACHING PROTECTIVE COVER
ENGR
R HERRON
38.10
1.50
8.13 3
.32 MIN.
3.56
.14
2.38
.09
48.77
1.92
CAVITY FOR KEYING KIT, TYP. 2 PLCS.
ACCESSORY P/N 310113461 (2 KEYS PER KIT)
NOT INCLUDED WITH RECEIVER
B
B
64.52
2.54
71.63
2.82
4.06
R.160 MAX. TYP.
19.05
.75
RECOMMENDED
PANEL CUTOUT
[2.79] .11,
FOR MOUNTING USE
2-56 OR M2.5 TAPPED HOLE.
(SUPPLIED WITH 4X 2-56 SCREWS,
LOCK WASHERS AND NUTS)
5.08
.20
A
TOLERANCES ARE:
.XX = [.25].01
.XXX = [.13].005
UNLESS OTHERWISE SPECIFIED
45.58
1.79
CUSTOMER DRAWING
VIRGINIA PANEL CORPORATION
4. PROTECTIVE COVER INCLUDED WITH ASSEMBLY (NOT SHOWN)
WWW.VPC.COM
MINIMUM DISTANCE SHOULD INCREASE TO 1.32 INCHES WHEN MOUNTING 2 OR MORE ROWS OF
3 STAGGERED RECEIVERS.
2. MATERIALS:
FRAME: NICKEL PLATED ALUMINUM ALLOY
BUSHING: THERMOPLASTIC
MOUNTING HARDWARE: STAINLESS STEEL
1. FOR APPLICATION USE & CARE INFORMATION CONSULT VPC USERS GUIDE @WWW.VPC.COM
NOTES:
4
3
A
i1 RECEIVER ASSEMBLY
DIMENSIONS ARE SHOWN AS:
[MILLIMETERS]
INCHES
2
SIZE
C
CAGE CODE
18117
SCALE: 1:1
DWG.NO.
310128101
1
310128101
4/7/09 SHEET
REV
B
1 OF 1