230V Network-Grade PDU Brochure 9533D6 (English)

U N I T S
P O W E R
U N I T S
D I S T R I B U T I O N
P O W E R
U N I T S
Reliable rackmount power distribution for high-density, high-availability IT environments
Load Meters, Network
Interface and Remote
Outlet Control Available
Models Available with Single-Phase Input or
3-Phase Input
Up to 45 Outlets
1U, 2U or 0U (Vertical)
Rackmount Installation
RELIABLE POWER DISTRIBUTION
NETWORK INTERFACE
Tripp Lite network-grade PDUs distribute power from a UPS system, generator
Monitored and Switched PDUs include
or wall outlet to multiple devices, including critical servers, storage and network/
a network interface (RJ45 Ethernet) that
telecom equipment. There are four distinct PDU types: Basic, Metered, Monitored
enables remote monitoring and remote
and Switched. Refer to the chart below to understand the features and benefits
condition reporting via SNMP, Web, SSH
associated with each type.
or telnet. This interface allows you to
Tripp Lite
PDU TYPES
Reliable
Power
Distribution
Local
Current
Metering
Remote
Current
Monitoring
Remote
Outlet
Power
Control
prevent downtime by enabling automatic
load threshold notification, to monitor
ambient temperature and humidity via the
optional
ENVIROSENSE
accessory
and
SWITCHED PDUs
to centralize your power management
Models Available:
10/16/32A
16A
Single-Phase
3-Phase
with Tripp Lite’s free PowerAlert Network
Management System.
MONITORED PDUs
Models Available:
16/32A
16A
Single-Phase
3-Phase
METERED PDUs
Models Available:
16/32A
16A
Single-Phase
3-Phase
BASIC PDUs
Monitored and/or Switched PDUs
Models Available:
16A Single-Phase
TCP/IP
D I S T R I B U T I O N
LOAD METER
Metered, Monitored and Switched PDUs display the connected
P O W E R
U N I T S
D I S T R I B U T I O N
230V Network-Grade PDUs (Power Distribution Units)
P O W E R
D I S T R I B U T I O N
POWER DISTRIBUTION UNITS
enables cycling of unresponsive devices from
equipment load (current draw) in amps. Monitored and
Switched 3-Phase PDUs include an advanced multimode load
meter that can display the PDU’s IP address, the load for each
bank/phase and the load for each outlet.
Load Meter
REMOTE OUTLET CONTROL
Switched PDUs allow remote control of
individual outlets for remote rebooting, load
shedding and more. Individual outlet control
any distance, reducing the need for expensive
and time-consuming trips to remote sites.
PowerAlert’s Remote Outlet Control Interface
Remote Workstation with PowerAlert Network
Management System (See last page for additional
information about PowerAlert.)
FEATURE FOCUS
E
A
I
PDUMH15HVNET
Similar Models: PDUMH20HVNET (16A Version),
PDUMNH20HV (16A Version without Remote
Individual Outlet Control)
B
D
E
C
Also includes: H
I
A
A
D
F
A
A
A
PDUMNH32HV
C
Also includes: E
C
F
E
C
J
Similar Models: PDUMH32HV (Without Network Interface),
PDUMH32HVNET (With Remote Individual Outlet Control)
H
A
I
E
C
C
D
D
B
PDU12IEC (front and back)
Similar Models: PDUH20DV (16A Version with Detachable Cord),
PDUNV (With Fixed Input Cord Terminating with C20 Inlet and Adapters Terminating with
A
C14, 5-15P, 5-20P, L5-20P and L6-20P)
A
E
A
I
C
A
E
A
A
B
PDUMH20HV
E
I
D
C
K
E
D
A
I
I
B
B
I
PDUMH20HVATNET (front and back)
Similar Model: PDUMH20HVAT (Without Network Interface)
B
B
Also includes: H
I
PLUG AND OUTLET IDENTIFICATION
J
PLUG
J
PDUMV20HV
PDU3XVN10G16
PDU3XVSR10G16
Similar Models:
PDUMV32HVNET
(32A Version),
PDUMNV20HV
(Without Remote Individual
Outlet Control)
Also includes:
Similar Model:
PDU3XVN3G16
(With 1 m Cord)
Similar Model:
PDU3XVSR3G16
(With 1 m Cord)
Also includes:
Also includes:
Also includes:
E G H
E G H
E
G
H
E
G
H
C14
C20
IEC-309 Blue 32A
(2P+E)
32A Blue IEC 60309 2P+E 6H-P
32A Blue IEC 60309 2P+E 6H-P
OUTLET
PDUMV20HVNET
IEC-309 Red 16A
(3P+N+E)
32A Blue IEC 60309 2P+E 6H-R
C13
C19
IEC-309 Blue 32A
(2P+E)
32A Blue IEC 60309 2P+E 6H-R
IEC-309 Red 16A
(3P+N+E)
A AC Outlets
G Toolless Mounting Buttons
B AC Inlet (C14 or C20)
Connects to a user-supplied input power
cord with a region-specific plug.
Switched Outlet
C Load Meter
Displays the connected equipment load
(current draw) in amps. Monitored and
Switched 3-Phase PDUs include an
advanced multimode load meter that
displays the PDU’s IP address, the
load for each bank/phase and the
load for each individual outlet.
Load Meter
E Removable Mounting Brackets
Toolless Mounting Button
H Removable Cord Retention Brackets
Secure power cords, reducing
the risk of disconnection.
I Metal Housing
Cord Retention Bracket
Maximizes durability and safety.
D Network Interface
Enables PDU management over
Ethernet LAN or WAN via SNMP,
a Web browser, SSH or telnet.
Also supports remote monitoring
of temperature, humidity and
dry contacts via ENVIROSENSE
accessory, sold separately.
Support toolless 0U (vertical)
installation in compatible
racks. Detachable 90° rotation
brackets allow PDU outlets to
face the rear of the rack for
improved access and airflow.
J Splash-Proof Plug
Network Interface
Splash-proof plug with IP44
protection rating connects to
a compatible outlet.
Splash-Proof Plugs
K Automatic Transfer Switch (ATS)
ENVIROSENSE
Support rackmount installation and surface mounting.
F Circuit Breakers
The PDU includes primary and secondary AC inputs, which
allows the PDU to automatically switch to the secondary
input if the primary input deviates from the designated
safe voltage/frequency range. ATS PDUs can provide
power redundancy to single-cord devices or make any online UPS system hot-swappable. Note: If the primary input
is plugged into a UPS, it must be an on-line UPS.
SPECIFICATIONS
NOMINAL
VOLTAGE
MAXIMUM METERS/
INPUT
OUTPUT
CURRENT BANKS AC INPUT
OUTLETS
MODEL
(50/60 HZ)
CONNECTOR (QUANTITY & TYPE)
RACK SPACE
3-PHASE SWITCHED PDUs (3-Phase Input, Single-Phase Output, Network-Grade Power Distribution, Load Meters, Network Interface and Remote Individual Outlet Control)
0U (178 cm long)(2, 3)
24 (21 C13+ 3 C19)
Input: 3-Phase 400V
16A
1/3
IEC-309 Red 16A (3P+N+E)(1)
PDU3XVSR10G16
(3 m cord)
Output: Single-Phase 230V
24 (21 C13+ 3 C19)
0U (178 cm long)(2, 3)
Input: 3-Phase 400V
16A
1/3
IEC-309 Red 16A (3P+N+E)(1)
PDU3XVSR3G16
(1 m cord)
Output: Single-Phase 230V
3-PHASE MONITORED PDUs (3-Phase Input, Single-Phase Output, Network-Grade Power Distribution, Load Meters and Network Interface)
0U (178 cm long)(2, 3)
36 (30 C13 + 6 C19)
Input: 3-Phase 400V
16A
1/3
IEC-309 Red 16A (3P+N+E)(1)
PDU3XVN10G16
(3 m cord)
Output: Single-Phase 230V
36 (30 C13 + 6 C19)
0U (178 cm long)(2, 3)
Input: 3-Phase 400V
16A
1/3
IEC-309 Red 16A (3P+N+E)(1)
PDU3XVN3G16
(1 m cord)
Output: Single-Phase 230V
3-PHASE METERED PDU (3-Phase Input, Single-Phase Output, Network-Grade Power Distribution and Load Meters)
45 (36 C13 + 9 C19)
0U (178 cm long)(2,3)
Input: 3-Phase 400V
16A
3/3
IEC-309 Red 16A (3P+N+E)(1)
PDU3XMV6G20
(2 m cord)
Output: Single-Phase 230V
SINGLE-PHASE SWITCHED PDUs (Network-Grade Power Distribution, Load Meters, Network Interface and Remote Outlet Control)
8 (C13)
1U
220/230/240V
10A
1/1
C14 inlet(4,5)
PDUMH15HVNET
220/230/240V
16A
1/1
C20 inlet(4,6)
8 (C13)
1U
PDUMH20HVNET
220/230/240V
16A
1/1
2 x C20 inlet(4,7)
10 (8 C13 + 2 C19)
1U
PDUMH20HVATNET
220/230/240V
32A
1/2
IEC-309 Blue 32A (2P+E)(1)
16 (C13)
2U
PDUMH32HVNET
220/230/240V
16A 1/1
C20 inlet(4)
24 (20 C13 + 4 C19)
0U (178 cm long)(2,3)
PDUMV20HVNET
16A 1/1
C20 inlet(4)
8 (7 C13 + 1 C19)
0U (99 cm long)(2,3)
220/230/240V
PDUMV20HVNET2
24 (20 C13 + 4 C19)
0U (178 cm long)(2,3)
220/230/240V
32A
1/2
IEC-309 Blue 32A (2P+E)(1)
PDUMV32HVNET
SINGLE-PHASE MONITORED PDUs (Network-Grade Power Distribution, Load Meters and Network Interface)
8 (C13)
1U
220/230/240V
16A
1/1
C20 inlet(4)
PDUMNH20HV
220/230/240V
32A
2/2
IEC-309 Blue 32A (2P+E)(1)
16 (12 C13 + 4 C19)
2U
PDUMNH32HV
220/230/240V
16A
1/1
C20 inlet(4,2)
24 (20 C13 + 4 C19)
0U (178 cm long)(2,3)
PDUMNV20HV
16A 1/1
C20 inlet(4)
20 (18 C13 + 2 C19)
0U (90 cm long)(2,3)
220/230/240V
PDUMNV20HV2
SINGLE-PHASE METERED PDUs (Network-Grade Power Distribution and Load Meters)
10 (8 C13 + 2 C19)
1U
220/230/240V
16A
1/1
C20 inlet(4,6)
PDUMH20HV
220/230/240V
16A
1/1
2 x C20 inlet(4,7)
10 (8 C13 + 2 C19)
1U
PDUMH20HVAT
220/230/240V
32A
2/2
IEC-309 Blue 32A (2P+E)(1)
18 (16 C13 + 2 C19)
2U
PDUMH32HV
220/230/240V
16A
1/1
C20 inlet(4)
38 (32 C13 + 6 C19)
0U (162 cm long)(2,3)
PDUMV20HV
SINGLE-PHASE BASIC PDUs (Network-Grade Power Distribution)
14 (12 C13 + 2 C19)
1U or 0U (44 cm long)(2)
220/230/240V
16A
0/1
C20 inlet(4)
PDU12IEC
14 (12 C13 + 2 C19)
1U or 0U (44 cm long)(2)
220/230/240V
16A
0/1
C20 inlet(4,8)
PDUNV
14 (12 C13 + 2 C19)
1U or 0U (44 cm long)(2)
220/230/240V
16A
0/1
C20 inlet(4,9)
PDUH20DV
HOT-SWAP PDUs (Dual Inputs and Manual Transfer Switch Add Hot-Swap Capability to Compatible UPS Systems up to 3 kVA)
8 (C13)(12)
2U(14)
220/230/240V
10A
0/1
2 x C14 inlet(4,10)
PDUBHV10
8 (6 C13 + 2 C19)(13)
2U(14)
220/230/240V
16A
0/1
2 x C20 inlet(4,11)
PDUBHV20
Certifications vary by model. (1) Splash-proof plug (IP44 protection rating). (2) 0U represents vertical rack installation. (3) Includes toolless mounting buttons. (4) Connect each inlet to a user-supplied input power cord
with a region-specific plug if required. (5) Includes detachable 198 cm input cord with C14 plug. (6) Includes detachable 259 cm input cord with C20 plug. (7) Includes primary and secondary AC inputs. Also includes two
366 cm input cords with C20 plugs. (8) Includes 305 cm input cord with C20 plug. (9) Includes 366 cm cord with C20 plug. (10) Includes two 183 cm input cords (one fixed cord for UPS input and one detachable cord for
utility input) with C14 plugs. (11) Includes one fixed 183 cm input cord (for UPS input) and one detachable 152 cm input cord (for utility input) with C20 plugs. (12) Also has C13 outlet for UPS connection. (13) Also has
C19 outlet for UPS connection. (14) Shallow depth allows the PDU to fit behind select UPS systems without using additional rack space.
CENTRALIZED POWER MANAGEMENT WITH POWERALERT NMS
PowerAlert NMS (Network Management System) software is included with Monitored and Switched PDUs, allowing IT managers
to access all PDU functions from any location. PowerAlert NMS can auto-discover and manage hundreds of Monitored or Switched
PDUs and associated environmental sensors (model ENVIROSENSE, sold separately) over the network from a single interface.
• Monitor PDUs remotely, including load levels, other power conditions,
environmental conditions and more. Receive alerts via e-mail,
text-messaging or SNMP if values exceed user-defined alarm thresholds.
• Mass-configure PDUs with pre-defined settings or firmware updates.
• Log power events and data according to user-defined parameters.
• Reboot unresponsive devices from any distance, reducing the need
for expensive and time-consuming trips to remote sites. (Switched PDUs)
• Shed nonessential loads automatically during power failures to increase
the runtime of critical systems. (Switched PDUs)
• Prevent unauthorized loads by locking out unused outlets. (Switched PDUs)
• Schedule equipment idling to reduce power costs by turning off selected
devices during off-hours. (Switched PDUs)
PowerAlert Network Management System
POWER CORDS & ACCESSORIES
Model
Plug
Outlet
Length
Rating
Description
P004-002-5
C14
C13
0,6 m
10A / 100-250V
Cord (5-Pack)
P004-002-13LA
C14
C13 (90° Left)
0,6 m
10A / 100-250V
Cord
P004-002-13RA
C14
C13 (90° Right)
0,6 m
10A / 100-250V
Cord
P005-002
C14
C13
0,6 m
15A / 100-250V
Cord
P005-006
C14
C13
1,8 m
15A / 100-250V
Cord
P005-010
C14
C13
3m
15A / 100-250V
Cord
P047-002
C14
C19
0,6 m
15A / 100-250V
Cord
P047-004
C14
C19
1,2 m
15A / 100-250V
Cord
P047-006
C14
C19
1,8 m
15A / 100-250V
Cord
P047-010
C14
C19
3m
15A / 100-250V
Cord
P036-002
C20
C19
0,6 m
20A / 100-250V
Cord
P036-002-19LA
C20
C19 (90° Left)
0,6 m
20A / 100-250V
Cord
P036-002-19RA
C20
C19 (90° Right)
0,6 m
20A / 100-250V
Cord
P036-006
C20
C19
1,8 m
20A / 100-250V
Cord
P032-007
C20
C13
2,1 m
20A / 100-250V
Cord
P056-006
BS1363
C13
1,8 m
5A / 200-250V
Cord
P052-008
BS1363
C19
2,4 m
13A / 200-250V
Cord
P054-006
CEE 7/7
C13
1,8 m
10A / 200-250V
Cord
P050-008
CEE 7/7
C19
2,4 m
16A / 200-250V
Cord
P070-010
IEC-309 Blue (2P + E)
C19
3m
16A / 200-250V
Cord
C14
Wonpro*
2,5 cm
10A / 100-250V
Adapter
UNIPLUGINT
* The Wonpro universal outlet is compatible with most household plugs worldwide.
Model
ENVIROSENSE
Description
Remote environmental sensor for Monitored and Switched PDUs. Monitors ambient temperature and humidity. Also monitors and controls alarm,
security and telecom devices through contact closure communications. Can monitor up to three additional environmental sensors. Connects to
optional SRSWITCH magnetic switch kit for rack enclosure door entry detection. 3,6 m connection cord.
SRSWITCH
Magnetic switch kit. Includes two entry detection switches for rack enclosure doors. Requires ENVIROSENSE.
P350-10N-10
10-pack of reusable black hook-and-loop cable ties. 25 cm x 1,6 cm.
ABOUT TRIPP LITE
Since 1922, Tripp Lite has established a global
reputation for quality manufacturing, superior value
and excellent service. Tripp Lite makes more than
2 500 products to power, protect and connect
electronic equipment, including UPS systems,
replacement batteries, PDUs, rack systems, cooling
solutions, surge suppressors, IP console servers,
KVM switches, cables, laptop accessories, power strips
and inverters. Learn more at www.tripplite.com.
Tripp Lite World Headquarters:
1111 W. 35th Street, Chicago, IL 60609 USA • +1.773.869.1212
Tripp Lite Middle East: +971.4.887.1633 • [email protected]
Tripp Lite Asia Pacific: +972.54.2057646 • [email protected]
Tripp Lite Eastern Europe: +36.1.203.7941 • [email protected]
Tripp Lite East/West Africa: +254.731.137.202 • [email protected]
Tripp Lite South Africa: +27.82.8099.043 • [email protected]
Copyright © 2013 Tripp Lite. All trademarks are the property of their owners.
Photos and illustrations may differ slightly from actual products.
Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice.