Link to SEMTECH test report

This Report is Semtech Confidential
Do Not Duplicate or Distribute
10/1000µs Lightning Surge Test Report
for
XFMRS, Inc
Page 1
This Report is Semtech Confidential
Do Not Duplicate or Distribute
¾
2 Devices are provided by XFMRS, Inc for testing:
1)
XF0013SGR1 – 1
2)
XF0013SGR1 – 2
¾ Each device is tested under 4 different testing configurations:
1)
Surge Pin 9. Ground Pin 11, 14, and 16
2)
Surge Pin 11. Ground Pin 9, 14, and 16
3)
Surge Pin 14. Ground Pin 9, 11, and 16
4)
Surge Pin 16. Ground Pin 9, 11, and 14
¾ Each testing configuration is subjected to 2 tests:
1) 1 10/1000µs lightning surge
2) 25 10/1000µs lightning surges
¾ Devices are curves traced and x-rayed after each test to ensure the electrical
characteristics and integrity of the fuse
¾ Both devices passed the 10/1000µs lightning surge test
Page 2
This Report is Semtech Confidential
Do Not Duplicate or Distribute
(Surge) Test configuration
Device
XF0013SGR1 - 1
VBR at
VBR at
VBR at
VBR at
VBR at
1mA
1mA
1mA
1mA
1mA
IR at 5V
IR at 5V
IR at 5V
IR at 5V
IR at 5V
Pin 1 to 5 Pin 3 to 5 Pin 4 to 5 Pin 6 to 5 Pin 8 to 5 Pin 1 to 5 Pin 3 to 5 Pin 4 to 5 Pin 6 to 5 Pin 8 to 5
curve tracer
Before Surge
7.6
7.6
7
7.6
Generator to pin 16, ground 11, 14, 9
7.6
less than 10nA
After 1 10/1000 Surge
7.6
7.6
7.1
7.6
Generator to pin 16, ground 11, 14, 9
7.6
less than 10nA
After 25 10/1000 Surge
7.6
7.6
7.1
7.6
Generator to pin 14, ground 16, 9, 11
7.6
less than 10nA
After 1 10/1000 Surge
7.6
7.6
7
7.6
Generator to pin 14, ground 16, 9, 11
7.6
less than 10nA
After 25 10/1000 Surge
7.6
7.6
7
7.6
Generator to pin 11, ground 16, 14, 9
7.6
less than 10nA
After 1 10/1000 Surge
7.6
7.6
7
7.6
Generator to pin 11, ground 16, 14, 9
7.6
less than 10nA
After 25 10/1000 Surge
7.6
7.6
7.1
7.6
Generator to pin 9, ground 16, 14, 11
7.6
less than 10nA
After 1 10/1000 Surge
7.6
7.6
7.1
7.6
Generator to pin 9, ground 16, 14, 11
7.6
less than 10nA
After 25 10/1000 Surge
7.6
XF0013SGR1 - 2
Test Result
7.6
7.1
7.6
curve tracer
7.6
less than 10nA
Before Surge
7.7
7.7
7.2
7.7
Generator to pin 16, ground 11, 14, 9
7.7
less than 10nA
After 1 10/1000 Surge
7.7
7.7
7.2
7.7
Generator to pin 16, ground 11, 14, 9
7.7
less than 10nA
After 25 10/1000 Surge
7.7
7.7
7.2
7.7
Generator to pin 14, ground 16, 9, 11
7.7
less than 10nA
After 1 10/1000 Surge
7.7
7.7
7.2
7.7
Generator to pin 14, ground 16, 9, 11
7.7
less than 10nA
After 25 10/1000 Surge
7.7
7.7
7.2
7.7
Generator to pin 11, ground 16, 14, 9
7.7
less than 10nA
After 1 10/1000 Surge
7.7
7.7
7.1
7.7
Generator to pin 11, ground 16, 14, 9
7.7
less than 10nA
After 25 10/1000 Surge
7.7
7.7
7.2
7.7
Generator to pin 9, ground 16, 14, 11
7.7
less than 10nA
After 1 10/1000 Surge
7.7
7.7
7.2
7.7
Generator to pin 9, ground 16, 14, 11
7.7
less than 10nA
After 25 10/1000 Surge
7.7
7.7
7.2
7.7
7.7
less than 10nA
**XF0013SGR1 has the SRV05-4 on the IC side and the LC04-6 x 2 on the line side
Page 3
This Report is Semtech Confidential
Do Not Duplicate or Distribute
Test Result Cont.
XF0013SGR1-1 Before Surge
Fuse 1
SRV05-4
Fuse 2
XF0013SGR1-1 After Surge
Fuse 1
SRV05-4
Fuse 2
Page 4
This Report is Semtech Confidential
Do Not Duplicate or Distribute
Test Result Cont.
XF0013SGR1-2 Before Surge
Fuse 1
SRV05-4
Fuse 2
XF0013SGR1-2 After Surge
Fuse 1
SRV05-4
Fuse 2
Page 5