STMICROELECTRONICS TSI180B1

TSIxxB1
®
Application Specific Discretes
A.S.D.
TERMINAL SET INTERFACE
PROTECTION AND DIODE BRIDGE
MAIN APPLICATION
Telecom equipment requiring combined
protection against transient overvoltages and
rectification by diode bridge :
Telephone set
Base station for cordless set
Fax machine
Modem
Caller Id equipment
Set top box
DESCRIPTION
SO8
SCHEMATIC DIAGRAM
The TSIxxB1 provides the diode bridge and the
crowbar protection function that can be found in
most of telecom terminal equipment.
Integrated monolithically within a SO8 package,
this ASD device allows space saving on the
board and greater reliability.
FEATURES
STAND-OFF VOLTAGE FROM 62V TO 265V
PEAK PULSE CURRENT : 30 A (10/1000 µs)
MAXIMUM DC CURRENT : IF = 0.2 A
HOLDING CURRENT :150 mA
1
8
2
7
3
6
4
5
IN ACCORDANCE WITH THE FOLLOWING
STANDARDS :
µs
µs
µs
µs
µs
µs
1.5 kV
38A
2 kV
40A(*)
1.5 kV
38A
10/1000 µs
10/1000 µs
FCC Part 68
2/10
µs
2/10
µs
MIL STD883C Method 3015-6
(*) with series resistor or PTC.
1 kV
30A(*)
2.5 kV
75A (*)
CCITT K17 - K20
VDE 0433
CNET
10/700
5/310
10/700
5/310
0.5/700
0.2/310
Bellcore
TR-NWT-000974:
BENEFITS
Diode bridge for polarity guard and crowbar
protection within one device.
Single chip for greater reliability
Reduces component count versus discrete
solution
Saves space on the board
TM: ASD is trademarks of SGS-THOMSON Microelectronics.
January 1998 - Ed: 3
1/9
TSIxxB1
TYPICAL APPLICATION
PTC
Telecom terminals have a diode bridge for polarity
guard, located at the line interface stage. They also
have above this diode bridge one crowbar
protection device that is mandatory to prevent
atmospheric effects and AC mains disturbances
from damaging the electronic circuitry that follows
the diode bridge.
SGS-THOMSON proposes a one chip device that
includes both protection and diode bridge. This is
the concept of the TSIxxB1 devices.
Fig. 1 : The various uses of the TSIxxB1 in a conventional telecom network
2/9
TSIxxB1
ELECTRICAL PARAMETERS
The VRM value corresponds to the maximum
voltage of the application in normal operation. For
instance, if the maximum line voltage is ranging
between ±100VRMS of ringing plus 48V of battery
voltage, then the protection chosen for this application shall have a VRM close to 200V.
The VBO is the triggering voltage. This indicates the
voltage limit for which the component
short-circuits. Passing this VBO makes the device
turn on.
TSIxxB1 BEHAVIOUR WITH REGARD TO
SURGE STANDARD :
The TSIxxB1 is able to replace both diode bridge
and usual discrete protection on telecom
terminals. Furthermore it complies with the CCITT
K17 recommendations :
10/700 µs waveform surge test, ± 1.5kV
AC power induction test
AC power contact test
The IBO is the current that makes the device turn
on. Indeed, if we want a Trisil to be turned on not
only the voltage across it shall pass the VBO value
but the current through it shall also pass the IBO
value.
In other words, if a voltage surge occurring on the
line is higher than the VBO value of a Trisil, whereas
the line surge current is limited to a value that does
not exceed the Trisil’s IBO value, then the Trisil will
never turn into short circuit. At this time the surge
will be clamped by the Trisil.
Anyhow the electronic circuitry located after the
Trisil will always be protected whatever the Trisil
state is (crowbar or clamping mode).
The IH stands for the holding current. When the
Trisil is turned on, as soon as the crossing current
surge gets lower than this IH value, the Trisil
protection device turns back in its idle state.
Remark : for this reason the Trisil ’s IH value shall
be chosen higher than what the maximum telecom
line current can be.
Fig. 2 : Test circuit for the CCITT K17 recommendations
Ω
3/9
TSIxxB1
TEST # 1
LIGHTNING SIMULATION
This test concerns the 10/700 µs waveform surge,
± 1.5 kV.
The surge generator used for the test has the
following circuitry (fig.2).
Fig. 2 : 10/700 µs waveform surge generator circuit
Ω
Ω
Ω
The behaviour of the TSI200B1 to this lightning surge is given below (fig. 3).
Fig. 3 : Voltage across the TSI200B1 at the + and - terminations and current throught it
for a 1.5 kV positive surge (fig.3a) and negative surge (fig. 3b)
These curves show the peak voltage the surge
generates across the TSI200B1 + and terminations. This lasts a short time (≈ 2 µs) and
after, as the internal protection gehaves like a short
circuit. The voltage drop across the TSIxxB1
becomes a few volts. In the meanwhile all the
surge current flows in the protection.
As far as the 10/700 µs waveform surge test is
concerned,the TSIxxB1 withstand the ± 1.5 kV
test.
4/9
TSIxxB1
TEST # 2
AC POWER INDUCTION TEST
This test simulates the induction phenomena that
can happen between telecom lines and AC mains
lines (fig. 4).
Fig. 4 : AC power induction test circuit
TEST #3
AC POWER CONTACT TEST
This test simulates the direct contact between the
telecom lines and the AC mains lines.
The AC power contact test consists in applying
240VRMS through a 10Ω PTC during 15 minutes
long on the device under test. The CCITT K17
recommendation specifies an internal generator
impedance allowing 10 ARMS when in short circuit.
The behavior of the TSI200B1 with respect to this
surge is given in figure 6.
Fig. 6 : Voltage at the TSI200B1 + & - terminations
and the current through it.
Part #1
test conditions :
VRMS = 240 V
R = 600 Ω
t = 0.2 s
test conditions :
VRMS = 600 V
R = 600 Ω
t = 0.2 s
Part #2
Fig. 5 : Voltage at the + and - terminations of the
TSI200B1, and current through it
while test part 1 is applied.
The figure 6 shows that after 250ms there is no
current anymore flowing through the TSI200B1
device. This is due to the action of the serial PTC
that limits the current through the line. This PTC is
mandatory for this test. It can also be replaced by a
fuse or any other serial protection that "opens" the
line loop under AC contact test.
The TSIxxB1 withstand the AC power induction
test in both cases.
5/9
TSIxxB1
ABSOLUTE MAXIMUM RATINGS (Tamb = 25°C)
Symbol
IPP
IF
Parameter
Value
Unit
Non repetitive peak on-sate current (see note 1)
10/1000 µs (open circuit voltage wave shape 10/100 µs)
5/310 µs (open circuit voltage wave shape 10/700 µs)
2/10 µs (open circuit voltage wave shape 2/10 µs)
30
40
75
A
Maximum DC current
0.2
A
5
3.5
A
- 55 to +150
150
°C
260
°C
ITSM
Non repetitive surge peak on-state current
Tstg
Tj
Storage temperature range
Maximum junction temperature
TL
Maximum lead temperature for soldering during 10 s
Note 1 : Pulse waveform :
10/1000µs tr=10µs
5/310µs
tr=5µs
2/10µs
tr=2µs
tp = 20 ms
t = 1s
% I PP
tp=1000µs
tp=310µs
tp=10µs
100
50
0
tr
t
tp
THERMAL RESISTANCE
Symbol
Rth(j-a)
Parameter
Junction to ambient
Value
Unit
170
°C/W
ELECTRICAL CHARACTERISTICS (Tamb=25°C)
Symbol
6/9
Parameter
VRM
Stand-off voltage
VBO
Breakover voltage
VBR
Breakdown voltage
IH
Holding current
IBO
Breakover current
IRM
Leakage current at VRM
IPP
Peak pulse current
C
Capacitance
αT
Temperature coefficient
I
IPP
IBO
IH
IRM
V
VRM
VBO
TSIxxB1
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C)
1 - PROTECTION DEVICES PARAMETERS
IRM @ VRM
Type
µA
V
max.
VBO @ IBO
IH
IBO
C
note1
note2
note1
note3
V
mA
mA
mA
pF
max.
min.
min.
max.
typ.
TSI62B1
1
5
50
62
90
150
50
400
200
TSI180B1
1
5
50
180
250
150
50
400
200
TSI200B1
1
5
50
200
290
150
50
400
200
TSI220B1
1
5
50
220
330
150
50
400
200
TSI265B1
1
5
50
265
380
150
50
400
200
Note 1 : Measured at 50 Hz, one cycle
Note 2 : See test cricuit
Note 3 : VR = 0V, F = 1MHz, between pins 1 and 8.
2 - DIODE BRIDGE PARAMETERS
Symbol
VF
(for one diode)
Test condition
IF = 20 mA
IF = 100 mA
Value
Unit
0.9
1.1
V
V
FUNCTIONAL HOLDING CURRENT (I H) TEST CIRCUIT : GO - NO GO TEST
R
D.U.T.
- VP
VBAT = - 48 V
Surge generator
This is a GO-NOGO Test which allows to confirm the holding current (IH) level in a functional
test circuit.
TEST PROCEDURE :
1) Adjust the current level at the IH value by short circuiting the D.U.T.
2) Fire the D.U.T with a surge Current : Ipp = 10A , 10/1000 µs.
3) The D.U.T will come back off-state within a duration of 50 ms max.
7/9
TSIxxB1
MARKING
Type
Marking
TSI62B1
TSI62
TSI180B1
TSI180
TSI200B1
TSI200
TSI220B1
TSI220
TSI265B1
TSI265
ORDER CODE
TSI 265
Terminal
Set
Interface
B
1 RL
RL = tape& reel (2500 pcs).
= tube (100 pcs).
SO8 Package
VBR min.
8/9
TSIxxB1
PACKAGE MECHANICAL DATA
SO8
REF. DIMENSIONS
Millimetres
Min.
Typ.
A
a1
0.1
a2
Inches
Max. Min.
Typ.
Max.
1.75
0.069
0.25 0.004
0.010
1.65
0.065
b
0.35
0.48 0.014
0.019
b1
0.19
0.25 0.007
0.010
C
0.50
c1
0.020
45° (typ)
D
4.8
5.0
0.189
0.197
E
5.8
6.2
0.228
0.244
e
1.27
0.050
e3
3.81
0.150
F
3.8
4.0
0.15
0.157
Packaging : product supplied in tape and reel or antistatic tubes.
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of
use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by
implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject to
change without notice. This publication supersedes and replaces all information previously supplied.
STMicroelectronics products are not authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
© 1998 STMicroelectronics - Printed in Italy - All rights reserved.
STMicroelectronics GROUP OF COMPANIES
Australia - Brazil - Canada - China - France - Germany - Italy - Japan - Korea - Malaysia - Malta - Mexico - Morocco - The
Netherlands - Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A.
9/9