Moisture Sensitivity Level 3 Test Report Series No : TSM (Single Output) Approved By: Issued By: Tested By: Issued Date:July,2006 Test Flow and Test Results for TSM 0505S Electrical Test Test Conditions Vin=5 Vdc, Load=200mA, Temperature=+25℃ Number of Devices under Test 5 pcs Test Standard Results PASS Results PASS Results PASS IPC/JEDEC J-STD-020C Results PASS IPC/JEDEC J-STD-020C Results PASS IPC/JEDEC J-STD-020C Results PASS Minmax Spec I.R. & Hi-Pot Test Test Conditions I.R.=1GΩ at 500VDC, Hi-Pot=1000VDC Number of Devices under Test 5 pcs Test Standard Minmax Spec Bake Test Test Conditions Temperature at 125 +5/-0℃ for 24 Hours Number of Devices under Test 5 pcs Test Standard IPC/JEDEC J-STD-020C Soak Test Test Conditions Temperature at 60℃/60%RH for 40 Hours Number of Devices under Test 5 pcs Test Standard Reflow Cycles Test Conditions 3 Cycles (Figure 1) Number of Devices under Test 5 pcs Test Standard Visual Inpection Test Conditions Number of Devices under Test Optical Microscope (40X) 5 pcs Test Standard P.1 of 4 Test Flow and Test Results for TSM 0505S X-Ray Inpection Test Conditions Inpected by ETC (Electronics Testing Center, Taiwan) (Figure 2) Numder of Devices under Test 5 pcs Test Standard IPC/JEDEC J-STD-020C Results PASS C-Sam Inpection Test Conditions Inpected by ETC (Electronics Testing Center, Taiwan) (Figure 3) Number of Devices under Test 5 pcs Test Standard IPC/JEDEC J-STD-020C Results PASS Generate Report Conclusion: After MSL test process, there’s no abnormal situation found and met all the electrical characteristics. We ensure our units should be ranked Level 3 without failure. P.2 of 4 Figure 1 Profile 15/06/2006 TRACO TSM0505S 70.00 cm/Min Figure 2 X-Ray P.3 of 4 Figure 3 C-Sam P.4 of 4