Features ● ● ● ● ● Unregulated Converters 1:1 Input Range Low Cost 1W Converter Efficiency to 75% -40°C to +85°C Operating Temperature Range UL Certified ECONOLINE DC/DC-Converter with 3 year Warranty Selection Guide Part Number Input Voltage (VDC) Output Voltage (VDC) Output Current (mA) Efficiency (typ.) 5 5 200 75% ROE-0505S 1 Watt SIP4 Single Output Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Input Voltage Range ±10% max. Output Voltage Accuracy -2% typ., ±5% max. Line Voltage Regulation (low line to high line at max. load) 1.2% typ. 20% to 100% load (5V output) 10% max. Output Ripple and Noise (20MHz BW limited) 52mVp-p typ. / 100mVp-p max. Operating Frequency (Vin=nominal input) 50kHz min. / 82kHz typ. / 105kHz max. Efficiency 75% typ. / 70% min. Isolation Test Voltage (tested for 1 second) 1000 VDC min. (rated for 1 minute*) 500VAC / 60Hz Isolation Capacitance 75pF max. Isolation Resistance (Viso=500V) Short-Circuit Protection 1 sec. Operating Temperature Range -40°C to +85°C Storage Temperature 95% RH Package Weight } MTBF (+85°C) Certification UL General Safety E-358085 UL-60950-1 Certified -55°C to +125°C Relative Humidity MTBF (+25°C) RoHS 2011/65/EU 6/6 1GΩ min. 1.4g Detailed Information see Application Notes chapter "MTBF" using MIL-HDBK 217F 2400 x 10³ hours using MIL-HDBK 217F 650 x 10³ hours Report: E358085-A4 ROE UL60950-1 *Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. Derating-Graph (Ambient Temperature) Typical Characteristics 100 Tolerance Envelope Output Voltage +10% +5% V Nom. Typical L o ad Line +5% 2% 5% 10% 50% 100% +Vout and -Vout Load Current (%) www.recom-power.com REV: 0/2015 Output Power (%) 80 60 40 Safe Operating Area 20 0 -40 0 50 150 100 85 Operating Temperature °C Refer to Application Notes E-41 ROE Series ECONOLINE DC/DC-Converter Typical Characteristics ROE-0505S 100 90 25 20 15 Efficiency % Deviation from Nominal % Deviation/Load 10 5 0 -5 -10 0 10 20 30 40 50 60 70 80 90 100 Load % 80 70 60 50 40 30 20 10 0 Efficiency/Load 0 10 20 30 40 50 60 Load % 70 80 90 100 Package Style and Pinning Single SIP 4PIN Package 1 6.00 2 3 4 ROE BOTTOM VIEW Recommended Footprint Details 11.50 1.00 +0.15/-0 RECOM ROE-0505S 1208 Pb 1 2 3 0.51 typ. 7.62 2.54 10.00 2.54 Pin Connections Pin # Function 1 -Vin 2 +Vin 3 -Vout 4 +Vout Unit: Tolerance: mm ± 0.25 mm 0.50 4 4.10 2.54 The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-42 REV: 0/2015 www.recom-power.com