Datasheet

Features
●
●
●
●
●
Unregulated
Converters
1:1 Input Range
Low Cost 1W Converter
Efficiency to 75%
-40°C to +85°C Operating Temperature Range
UL Certified
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Selection Guide
Part
Number
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(typ.)
5
5
200
75%
ROE-0505S
1 Watt SIP4
Single Output
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
±10% max.
Output Voltage Accuracy
-2% typ., ±5% max.
Line Voltage Regulation
(low line to high line at max. load)
1.2% typ.
20% to 100% load (5V output)
10% max.
Output Ripple and Noise (20MHz BW limited)
52mVp-p typ. / 100mVp-p max.
Operating Frequency (Vin=nominal input)
50kHz min. / 82kHz typ. / 105kHz max.
Efficiency
75% typ. / 70% min.
Isolation Test Voltage
(tested for 1 second)
1000 VDC min.
(rated for 1 minute*)
500VAC / 60Hz
Isolation Capacitance
75pF max.
Isolation Resistance
(Viso=500V)
Short-Circuit Protection
1 sec.
Operating Temperature Range
-40°C to +85°C
Storage Temperature
95% RH
Package Weight
}
MTBF (+85°C)
Certification
UL General Safety
E-358085
UL-60950-1 Certified
-55°C to +125°C
Relative Humidity
MTBF (+25°C)
RoHS
2011/65/EU
6/6
1GΩ min.
1.4g
Detailed Information see
Application Notes chapter "MTBF"
using MIL-HDBK 217F
2400 x 10³ hours
using MIL-HDBK 217F
650 x 10³ hours
Report: E358085-A4
ROE
UL60950-1
*Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
Derating-Graph
(Ambient Temperature)
Typical Characteristics
100
Tolerance Envelope
Output Voltage
+10%
+5%
V Nom.
Typical L
o
ad Line
+5%
– 2%
– 5%
10%
50%
100%
+Vout and -Vout Load Current (%)
www.recom-power.com
REV: 0/2015
Output Power (%)
80
60
40
Safe Operating Area
20
0
-40
0
50
150
100
85
Operating Temperature °C
Refer to Application Notes
E-41
ROE Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
ROE-0505S
100
90
25
20
15
Efficiency %
Deviation from Nominal %
Deviation/Load
10
5
0
-5
-10
0 10 20 30 40 50 60 70 80 90 100
Load %
80
70
60
50
40
30
20
10
0
Efficiency/Load
0
10
20
30
40
50 60
Load %
70
80
90 100
Package Style and Pinning
Single SIP 4PIN Package
1
6.00
2
3
4
ROE
BOTTOM VIEW
Recommended Footprint Details
11.50
1.00 +0.15/-0
RECOM
ROE-0505S
1208 Pb
1
2
3
0.51 typ.
7.62
2.54
10.00
2.54
Pin Connections
Pin #
Function
1
-Vin
2
+Vin
3
-Vout
4
+Vout
Unit:
Tolerance:
mm
± 0.25 mm
0.50
4
4.10
2.54
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-42
REV: 0/2015