Full Datasheet

AC/DC Power Modules
TML 100C Series, 85-100 Watt
CB
Scheme
Features
◆ Very compact power modules
UL 60950-1
with screw terminal connection
◆ Active PFC, power factor >0.95 (230VAC), >0.99 (115 VAC)
◆ High efficiency up to 93% typ.
◆ Remote On/Off input
◆ Adjustable output voltage ±5%
◆ LED output indicator
◆ Universal input 100-240 VAC nominal
◆ Low leakage current
◆ EMI meets EN 55022, class B
◆ Protection class ll prepared
The TML 100C series modules are very compact 85–100 Watt power supplies in a
fully encapsulated plastic case. Active power factor correction and high efficiency
across full load range qualify these modules for installation in energy related products. They feature screw terminals for easy installation. The TML 100C series is
accompanied by an international safety approval package for worldwide markets.
Models
Order code
Output power
max.
Output voltage
Output current
max.
Efficiency
115 VAC / 230 VAC
TML 100-112C
85
12 VDC
7000 mA
89.5 % / 91.0 %
TML 100-115C
85
15 VDC
5660 mA
90.0 % / 91.5 %
TML 100-124C
100
24 VDC
4200 mA
92.5 % / 93.5 %
TML 100-148C
100
48 VDC
2100 mA
93.0 % / 94.5 %
Full TML and TMLM Series Model Range
Series
Description
TMLM 04
4 Watt, PCB mount, single and dual output models
TMLM 05
5 Watt, PCB mount, single output models
TMLM 10
10 Watt, PCB mount, single output models
TMLM 20
20 Watt, PCB mount, single output models (compact design)
TML 20
20 Watt, PCB & chassis mount, single, dual and triple output models
TML 40
40 Watt, PCB & chassis mount, single, dual and triple output models
http://www.tracopower.com
Datasheet
www.tracopower.com/products/tmlm.pdf
www.tracopower.com/products/tml.pdf
Page 1 of 3
AC/DC Power Modules
TML 100C Series
85-100 Watt
Input Specifications
Input voltage ranges
– nominal 100 – 240 VAC (universal input)
– AC full range 90 – 264 VAC
– DC Input 120 – 370 VDC
Input frequency 47 – 63 Hz
Input current at full load (115 VAC / 230 VAC nominal input) < 2.0 A / < 1.0 A max.
Leakage current 0.5 mA max.
Harmonic limits EN 61000-3-2, Class A
– Power factor >0.99 at 115 VAC, >0.95 at 230 VAC
Output Specifications
Voltage set accuracy ±2 %
Output voltage adjustment range ±5% (see page 3)
Minimum load 3% of rated max current (operation at lower
load condition is safe but a higher output ripple
will be experianced)
Ripple and noise (20 MHz bandwidth)
Regulation 12
15
24
48
VDC
VDC
VDC
VDC
model:
model:
model:
model:
120 mV max.
150 mV max.
200 mV max.
240 mV max.
– input variation±1%
– load variation±1%
Current limitation 105% – 180% of rated output power.
(automatic recovery)
Overvoltage protection by Zehner diode.
Short circuit protection indefinite (hiccup, automatic recovery)
Hold-up time 10 ms min. (110VAC)
Max. capacitive load
12
15
24
48
VDC
VDC
VDC
VDC
model:
model:
model:
model:
50‘000 µF
40‘000 µF
6‘000 µF
1‘000 µF
General Specifications
Temperature ranges
–
–
–
–
Operating
Power derating above +50°C
Case max.
Storage (non operating)
–25°C to +70°C
2.0 %/K
+95°C
–25°C to +85°C
Temperature coefficient 0.03 %/°C
Efficiency
see model table
Remote On/Off control On: open or connection to -Vout
Off: external +5VDC
Humidity (non condensing) 95 % rel max.
Switching frequency (pulse width modulation PWM) 100–133 kHz
Isolation voltage
– Input/Output 3‘000 VAC
Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >250’000 h
Environmental compliance
– Reach www.tracopower.com/products/tml-reach.pdf
– RoHS RoHS directive 2011/65/EU
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3
AC/DC Power Modules
TML 100C Series
85-100 Watt
General Specifications
Electromagnetic compatibility (EMC), Emissions EN 61000-3-2:2006+A1:2009+A2:2009
EN 61000-3-3:2008
EN 55022, class B
Electromagnetic compatibility (EMC), Immunity EN 55024 : 2010
– Electrostatic discharge ESD (air/contact) EN 61000-4-2 ±2 kV / ±4 kV, criteria A
– RF field susceptibility EN 61000-4-3 3 V/m, criteria A
– Electrical fast transient / burst immunity input EN 61000-4-4 ±1 kV, criteria A
– Surge immunity line – neutral EN 61000-4-5, ±1 kV, criteria A
– Surge immunity line – PE, neutral – PE EN 61000-4-5 ±2 kV, criteria A
– Immunity to conducted RF disturbances EN 61000-4-6 3 V, criteria A
– Power frequency magnetic field immunity EN 61000-4-8 1 A/m, criteria A
– Mains voltage dips and interruptions EN 61000-4-11 30 % 500 ms, criteria A
95 % 10 ms, criteria A
95 % 2500 ms, criteria C
Protection class
class I and class II prepared
Safety standards IEC 60950-1 2nd ed +Am1
EN 60950-1:2006/A11:2009/A1:2010/A12:2011
UL 60950-1 2nd ed +Am1
Safety approvals – CB certificate for IEC/EN 60950-1
www.tracopower.com/products/tml100c-cb.pdf
– UL/cUL 60950-1 (online certification)
www.ul.com File e188913
Casing material plastic resin + fiberglass (UL 94V-0 rated)
Output voltage adjustment (Trim resistor [KOhm])
Trim up: Resistor from Trim to -Vout (conection 7-6)
Trim down: Resistor from Trim to +Vout (conection 7-5)
output voltage
12 VDC
15 VDC
24 VDC
48 VDC
85
95
90
85
nominal
open
open
open
open
–5%
220
300
600
1500
+5%
Outline Dimensions
4 x ø3.2
Connection
(0.24)
6.0
(4 x ø0.1.26)
con.
Output
1
AC in (L)
6
2
AC in (N)
7
3
FG
4
Remote On/Off
5
+Vout
6
-Vout
7
Trim
4
1
50.0 (2.0)
62.0 (2.48)
LED
2
5
Top view
3
128.0 (5.12)
6.0
(0.24)
(0.26)
Weight : 440 g (11.5 oz)
6.6
36.6 (1.46)
140.0 (5.6)
Dimensions in[mm], () = Inches
Tolerances = 0.5mm (0.02)
4 x ø3.0
(4 x ø0.12)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
4 x ø2.5
(4 x ø0.10)
24.0
Bottom view
13.0
(0.52)
(0.96)
www.tracopower.com
Rev. April 04. 2014
Page 3 of 3