AC/DC Power Modules TML 100C Series, 85-100 Watt CB Scheme Features ◆ Very compact power modules UL 60950-1 with screw terminal connection ◆ Active PFC, power factor >0.95 (230VAC), >0.99 (115 VAC) ◆ High efficiency up to 93% typ. ◆ Remote On/Off input ◆ Adjustable output voltage ±5% ◆ LED output indicator ◆ Universal input 100-240 VAC nominal ◆ Low leakage current ◆ EMI meets EN 55022, class B ◆ Protection class ll prepared The TML 100C series modules are very compact 85–100 Watt power supplies in a fully encapsulated plastic case. Active power factor correction and high efficiency across full load range qualify these modules for installation in energy related products. They feature screw terminals for easy installation. The TML 100C series is accompanied by an international safety approval package for worldwide markets. Models Order code Output power max. Output voltage Output current max. Efficiency 115 VAC / 230 VAC TML 100-112C 85 12 VDC 7000 mA 89.5 % / 91.0 % TML 100-115C 85 15 VDC 5660 mA 90.0 % / 91.5 % TML 100-124C 100 24 VDC 4200 mA 92.5 % / 93.5 % TML 100-148C 100 48 VDC 2100 mA 93.0 % / 94.5 % Full TML and TMLM Series Model Range Series Description TMLM 04 4 Watt, PCB mount, single and dual output models TMLM 05 5 Watt, PCB mount, single output models TMLM 10 10 Watt, PCB mount, single output models TMLM 20 20 Watt, PCB mount, single output models (compact design) TML 20 20 Watt, PCB & chassis mount, single, dual and triple output models TML 40 40 Watt, PCB & chassis mount, single, dual and triple output models http://www.tracopower.com Datasheet www.tracopower.com/products/tmlm.pdf www.tracopower.com/products/tml.pdf Page 1 of 3 AC/DC Power Modules TML 100C Series 85-100 Watt Input Specifications Input voltage ranges – nominal 100 – 240 VAC (universal input) – AC full range 90 – 264 VAC – DC Input 120 – 370 VDC Input frequency 47 – 63 Hz Input current at full load (115 VAC / 230 VAC nominal input) < 2.0 A / < 1.0 A max. Leakage current 0.5 mA max. Harmonic limits EN 61000-3-2, Class A – Power factor >0.99 at 115 VAC, >0.95 at 230 VAC Output Specifications Voltage set accuracy ±2 % Output voltage adjustment range ±5% (see page 3) Minimum load 3% of rated max current (operation at lower load condition is safe but a higher output ripple will be experianced) Ripple and noise (20 MHz bandwidth) Regulation 12 15 24 48 VDC VDC VDC VDC model: model: model: model: 120 mV max. 150 mV max. 200 mV max. 240 mV max. – input variation±1% – load variation±1% Current limitation 105% – 180% of rated output power. (automatic recovery) Overvoltage protection by Zehner diode. Short circuit protection indefinite (hiccup, automatic recovery) Hold-up time 10 ms min. (110VAC) Max. capacitive load 12 15 24 48 VDC VDC VDC VDC model: model: model: model: 50‘000 µF 40‘000 µF 6‘000 µF 1‘000 µF General Specifications Temperature ranges – – – – Operating Power derating above +50°C Case max. Storage (non operating) –25°C to +70°C 2.0 %/K +95°C –25°C to +85°C Temperature coefficient 0.03 %/°C Efficiency see model table Remote On/Off control On: open or connection to -Vout Off: external +5VDC Humidity (non condensing) 95 % rel max. Switching frequency (pulse width modulation PWM) 100–133 kHz Isolation voltage – Input/Output 3‘000 VAC Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >250’000 h Environmental compliance – Reach www.tracopower.com/products/tml-reach.pdf – RoHS RoHS directive 2011/65/EU All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 3 AC/DC Power Modules TML 100C Series 85-100 Watt General Specifications Electromagnetic compatibility (EMC), Emissions EN 61000-3-2:2006+A1:2009+A2:2009 EN 61000-3-3:2008 EN 55022, class B Electromagnetic compatibility (EMC), Immunity EN 55024 : 2010 – Electrostatic discharge ESD (air/contact) EN 61000-4-2 ±2 kV / ±4 kV, criteria A – RF field susceptibility EN 61000-4-3 3 V/m, criteria A – Electrical fast transient / burst immunity input EN 61000-4-4 ±1 kV, criteria A – Surge immunity line – neutral EN 61000-4-5, ±1 kV, criteria A – Surge immunity line – PE, neutral – PE EN 61000-4-5 ±2 kV, criteria A – Immunity to conducted RF disturbances EN 61000-4-6 3 V, criteria A – Power frequency magnetic field immunity EN 61000-4-8 1 A/m, criteria A – Mains voltage dips and interruptions EN 61000-4-11 30 % 500 ms, criteria A 95 % 10 ms, criteria A 95 % 2500 ms, criteria C Protection class class I and class II prepared Safety standards IEC 60950-1 2nd ed +Am1 EN 60950-1:2006/A11:2009/A1:2010/A12:2011 UL 60950-1 2nd ed +Am1 Safety approvals – CB certificate for IEC/EN 60950-1 www.tracopower.com/products/tml100c-cb.pdf – UL/cUL 60950-1 (online certification) www.ul.com File e188913 Casing material plastic resin + fiberglass (UL 94V-0 rated) Output voltage adjustment (Trim resistor [KOhm]) Trim up: Resistor from Trim to -Vout (conection 7-6) Trim down: Resistor from Trim to +Vout (conection 7-5) output voltage 12 VDC 15 VDC 24 VDC 48 VDC 85 95 90 85 nominal open open open open –5% 220 300 600 1500 +5% Outline Dimensions 4 x ø3.2 Connection (0.24) 6.0 (4 x ø0.1.26) con. Output 1 AC in (L) 6 2 AC in (N) 7 3 FG 4 Remote On/Off 5 +Vout 6 -Vout 7 Trim 4 1 50.0 (2.0) 62.0 (2.48) LED 2 5 Top view 3 128.0 (5.12) 6.0 (0.24) (0.26) Weight : 440 g (11.5 oz) 6.6 36.6 (1.46) 140.0 (5.6) Dimensions in[mm], () = Inches Tolerances = 0.5mm (0.02) 4 x ø3.0 (4 x ø0.12) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com 4 x ø2.5 (4 x ø0.10) 24.0 Bottom view 13.0 (0.52) (0.96) www.tracopower.com Rev. April 04. 2014 Page 3 of 3