TML Series, 20 & 40 Watt

AC/DC Power Modules
TML Series, 20­& 40 Watt
CB
Scheme
Features
◆ Encapsulated power supplies with
LVD
UL 60950-1
increased power density
◆ Replaces TML 15 and TML 30 series
◆ PCB mount or chassis mount with
screw terminals
◆ Single, dual and triple output models
◆ Universal input 90–264 VAC, 47–440 Hz
◆ EMI meets EN 55022, class B and
FCC, level B
◆ Protection class ll for TML 40 models
◆ Short circuit and overload protection
◆ 3-year product warranty
Also see:
TMLM Series, 4 to 20 Watt
highest power density, PCB mount.
www.tracopower.com/products/tmlm.pdf
The TML series are ultra compact AC/DC power supplies in a fully encapsulated
plastic case. They feature versions with screw terminals for easy installation or
with solder pins for direct PCB mounting. International safety approvals qualify
this product for worldwide markets. The TML series AC/DC modules offer an
interesting solution for many space critical applications in commercial and industrial electronic equipment.
Referance datasheet for primary TML models, see:
www.tracopower.com/products/tml-primary.pdf
(not recommended for new design in)
20 Watt Models
Order code
PCB mount
Chassis mount
TML 20103
TML 20103C
Output
power
max.
14.9 W
Output 1
Output 2
Output 3
3.3 VDC/4500 mA
TML 20105
TML 20105C
5.0 VDC/4000 mA
TML 20112
TML 20112C
12 VDC/1670 mA
TML 20115
TML 20115C
15 VDC/1340 mA
TML 20124
TML 20124C
24 VDC/840 mA
TML 20205
TML 20205C
+5.0 VDC/2000 mA
–5.0 VDC/2000 mA
TML 20212
TML 20212C
+12 VDC/833 mA
–12 VDC/833 mA
TML 20215
TML 20215C
+15 VDC/667 mA
–15 VDC/667 mA
TML 20512
TML 20512C
5 VDC/2800 mA
+12 VDC/250 mA
–12 VDC/250 mA
TML 20515
TML 20515C
5 VDC/2800 mA
+15 VDC/200 mA
–15 VDC/200 mA
http://www.tracopower.com
20 W
Page 1 of 5
AC/DC Power Modules
TML Series
20 & 40 Watt
40 Watt Models
Order code
Output
power
max.
Output 1
PCB mount
Chassis mount
TML 40103
TML 40103C
26.4 W 3.3 VDC/8000 mA
TML 40105
TML 40105C
5.0 VDC/8000 mA
TML 40112
TML 40112C
12 VDC/3333 mA
TML 40115
TML 40115C
15 VDC/2666 mA
TML 40124
TML 40124C
24 VDC/1667 mA
TML 40205
TML 40205C
TML 40212
TML 40212C
40 W
Output 2
Output 3
+5.0 VDC/4000 mA
–5.0 VDC/4000 mA
+12 VDC/1666 mA
–12 VDC/1666 mA
TML 40215
TML 40215C
+15 VDC/1333 mA
–15 VDC/1333 mA
TML 40252
TML 40252C
*5.0 VDC/5000 mA
*12 VDC/1250 mA
TML 40254
TML 40254C
*5.0 VDC/5000 mA
*24 VDC/625 mA
TML 40512
TML 40512C
*5.0 VDC/5000 mA
+12 VDC/600 mA
–12 VDC/600 mA
TML 40515
TML 40515C
*5.0 VDC/5000 mA
+15 VDC/500 mA
–15 VDC/500 mA
* Output floating
Input Specifications
Input voltage ranges
– AC input 90 – 264 VAC
– DC Input 100 – 375 VDC
Input frequency 47 – 440 Hz
Input current at full load (115 VAC / 230 VAC nominal input)
TML 20 models: 400 mA / 270 mA max.
TML 40 models: 860 mA / 460 mA max.
Leakage current 0.75 mA max.
External fuse (required)
TML 20 models: 2.0 A slow blow type (recommendation)
TML 40 models: 1.5 A slow blow type (recommendation)
Output Specifications
Voltage set accuracy
TML 20103 model: TML 20 models:
TML 40 single and symetric dual output models:
TML 40 asymetric dual and triple output models:
±3%
±2 %
±2 %
±3 % for output 1, ±5 % for output 2&3
Minimum load TML 20 single and dual output models: 0 %
TML 20 triple output models: 10 % (each output)
TML 40 single output models: 1 %
TML 40 symetric dual output models: 10 % (each output)
TML 40 asymetric dual and triple output models: 25 % (each output)
operation at lower load condition will not
damage these power supplies, how­­ever, they
may not meet all listed specifications.
Ripple and noise (20 MHz bandwidth)
TML 20 models: <0.7 % of Vout +90 mV [Vp-p]
TML 40, 3.3 VDC model: <50 mVp-p
TML 40 other models: <1 % of Vout [Vp-p]
Regulation – Input variation
single and symetric dual output models: 0.5 % (each output)
TML 20 triple output models: 1 % for output 1, 5 % for output 2&3
TML 40 asymetric dual and triple output models: 0.5 % for output 1, 5 % for output 2&3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 5
AC/DC Power Modules
TML Series
20 & 40 Watt
Output Specifications
Regulation – Load variation
TML 20 single output models:
TML 20 dual output models:
TML 20 triple output models:
TML 40 single output models:
TML 40 symetric dual output models:
TML 40 asymetric dual output models:
TML 40 triple output models:
1 %, 0–100 % load
3 % (each output), 10–100 % symetric load
2 % for output 1, 20–100 % load
5 % for output 2&3, 20–100 % symetric load
0.5 % 1–100 % load
1 % (each output), 10–100 % symetric load
2 % for output 1, 25–100 % load
6 % for output 2, 25–100 % load
3 % for output 1, 25–100 % load
7 % for output 2&3, 25–100 % symetric load
Current limitation above 105 % of rated output current.
Overvoltage protection by Zehner diode (main output only) 120 % of Vout typ.
Short circuit protection hiccup mode, indefinite (automatic recovery)
Overtemperature protection (TML 40 models only) at +100°C
Max. capacitive load [µF]
Model series
TML 20
TML 40
3.3 VDC
25‘000
60‘000
5.0 VDC
13‘000
40‘000
12 VDC
920
8‘600
15 VDC
820
6‘600
24 VDC
600
1400
+5.0 / –5.0 VDC
4300 / 4300
12‘000 / 12‘000
+12 / –12 VDC
560 /560
4‘400 / 4‘400
+15 / –15 VDC
220 /220
1‘000 / 1‘000
+5.0 / +12 VDC
–
10‘000 / 470
+5.0 / +24 VDC
–
10‘000 / 400
+5.0 / +12 / –12 VDC
3‘500 / 220 / 220
10‘000 / 780 / 780
+5.0 / +15 / –15VDC
3‘500 / 150 / 150
10‘000 / 900 / 900
Output:
Single output models
Dual output models symetric
Dual output models asymetric
Triple output models
General Specifications
Temperature ranges
– Operating
TML 20 models:
TML 40 models:
– Power derating above +50°C
– Case max. TML 40 models:
– Storage (non operating)
–25°C to +60°C
–40°C to +60°C
3.0 %/K
+95°C
–40°C to +85°C
Temperature coefficient 0.02 %/°C
Efficiency 75 – 84 % (depending on model)
Humidity (non condensing) 95 % rel max.
Switching frequency (pulse width modulation PWM)
TML 20 models: 100 kHz typ.
TML 40 models: 132 kHz typ.
Hold-up time 10 ms min.
Isolation voltage
– Input/Output 3‘000 VAC
Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >200’000 h
EMI / RFI conducted EN 55022, class B, FCC part 15, level B
EMC compliance
EN 55024
Protection class
TML 20 models: class I
TML 40 models: class II to IEC/EN 60536
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 5
AC/DC Power Modules
TML Series
20 & 40 Watt
General Specifications
Safety standards UL/cUL 60950-1, IEC/EN 60950-1
– Certification documents
www.tracopower.com/overview/tml
Casing material plastic resin + fiberglass (UL 94V-0 rated)
Environmental compliance
– Reach www.tracopower.com/overview/tml
– RoHS RoHS directive 2011/65/EU
Outline Dimensions
11.5
(0.45)
5
1
4
4.0
24.0 (0.94)
11.5
(0.79)
6
8.5
Bottom view
(0.33)
20.0
(0.79)
7
2
20.0
48.0 (1.89)
8.5
8
(0.45)
3
(0.33)
TML 20 models
for PCB mount:
62.0 (2.44)
22.0 (0.87)
8.0
(0.31)
(0.16)
70.0 (2.76)
Pin diameter ø 1.0 mm (0.039)
Weight: 110 g (3.9 oz)
Pinout / Connection
6.0
4.0
(0.23)
Pin/
con.
4 x ø3.5
(0.16)
27.6 (1.09)
TML 20C models
for chassis mount:
(4 x ø0.14)
46.0 (1.81)
54.6 (2.15)
4
1
2
5
Top view
Single
output
Dual
output
1
FG
2
AC in (N)
3
AC in (L)
Triple
output
4
no pin / nc
no pin / nc
Vout 3
5
–Vout 1
Vout 2
com. 2/3
6
no pin
com. 1/2
Vout 2
7
+Vout 1
+Vout 1
–Vout 1
8
no pin
no pin
nc = not to connect
+Vout 1
6
7
3
8
5.0
86.0
(3.38)
(0.20)
96.0 (3.78)
Weight: 155 g (5.5 oz)
http://www.tracopower.com
Dimensions in[mm], () = Inches
Tolerances = 0.5mm (0.02)
Page 4 of 5
AC/DC Power Modules
TML Series
20 & 40 Watt
Outline Dimensions
TML 40 models
for PCB mount:
(0.60)
8
15.24
3
12.7
(0.50)
5
2
3.85
31.75 (1.25)
12.7
(0.50)
6
(0.60)
Bottom view
15.24
55.88 (2.20)
63.5 (2.50)
7
4
81.3 (3.20)
25.0 (0.98)
6.0
(0.24)
(0.15)
89.0 (3.50)
Pin diameter ø 1.2 mm (0.047)
Weight : 280 g (9.9 oz)
TML 40C models
for chassis mount:
6.5
Pin/
con.
(0.25)
32.5 (1.28)
Pinout / Connection
4 x ø3.5
6.85
(0.23)
4
50.0 (1.97)
Dual sym.
output
1
(4 x ø0.14)
63.7 (2.50)
Single
output
1
2
3
Triple
output
no pin / nc
2
AC in (L)
3
AC in (N)
4
+Vout 1
Vout 1
+Vout 2
Vout 2
5
no pin / nc
no pin / nc
+Vout 1
+Vout 1
6
–Vout 1
com. 1/2
–Vout 2
com. 2/3
7
no pin / nc
no pin / nc
–Vout 1
–Vout 1
8
nc
Vout 2
no pin / nc
Vout 3
5
Top view
Dual asym.
output
6
nc = not to connect
7
8
6.0
100.0 (3.94)
(0.24)
112.0 (4.41)
Dimensions in[mm], () = Inches
Tolerances = 0.5mm (0.02)
Weight : 325 g (11.5 oz)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Rev. July 07. 2015
Page 5 of 5