A150 Series

TELEDYNE RELAYS
ULTRAMINIATURE
ATTENUATOR RELAY
SERIES
A150
DC TO 3 GHz
SERIES
DESIGNATION
RELAY TYPE
A150
ATTENUATOR RELAY SERIES
INTERNAL CONSTRUCTION
DESCRIPTION
The A150 series ultraminiature Attenuator Relays are designed for
attenuating RF signals in 50 ohm systems over a frequency range
from DC to 3 GHz. Their low profile and small grid spacing
makes them ideal for use when packaging density is a prime
consideration. The A150 eliminate the need for additional external
resistors.
UPPER CONTACT
MOVING CONTACT
LOWER CONTACT
ATTENUATOR PAD
These single section, switchable attenuator relays have internal
matched thin film attenuator pads in “L”, “T” or “Pi” configurations, as applicable. Relays are available in fixed increments
of 1, 2, 3, 4, 5, 6, 8, 10, 16, and 20 dB which can used singly or
in combination to achieve the attenuation levels desired.
SCHEMATIC DIAGRAM
The A150 attenuator relay features:
3
5
2
6
1
7
• Unique uni-frame motor design which provides high
magnetic efficiency and mechanical rigidity.
• Minimum mass components and welded
construction for maximum resistance to shock and vibration.
• Advanced cleaning techniques which assures
internal cleanliness.
• Gold plated, precious metal contacts which
provides excellent intermodulation performance.
• Flat amplitude vs. frequency response.
• High isolation between control and signal path.
• Stable attenuation vs. temperature.
• Excellent phase linearity.
• Highly resistant to ESD.
Terminal view. Case ground
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
Storage
Operating
-65˚C to +125˚C
-55˚C to =85˚C
Vibration (Note 1)
10 G to 500 Hz
Shock (Note 1)
30 G, RMS, 6 ms half sine
Enclosure
Hermetically sealed
Weight
0.11 oz. (3.12 g.) max.
Patent No. 5,315,273
82
SERIES A150
TYPICAL RF PERFORMANCE (Notes 2, 3 and 4)
2 dB ATTENUATOR
1 dB ATTENUATOR
VSWR
1.6
VSWR
ATTENUATION (dB)
1.6
0.70
ATTENUATION
1.4
0.90
1.90
ATTENUATION
2.00
1.00
1.2
1.70
1.80
0.80
1.4
ATTENUATION (dB)
1.2
1.10
2.10
VSWR
VSWR
2.20
1.20
1.0
1.0
1.30
1,000
2,000
3,000
2 .30
1,000
4,000
1.6
3,000
4,000
4 dB ATTENUATOR
3 dB ATTENUATOR
VSWR
2,000
FREQUENCY (MHz)
FREQUENCY (MHz)
VSWR
ATTENUATION (dB)
1.6
2.70
ATTENUATION (dB)
3.70
3.80
2.80
ATTENUATION
1.4
2.90
1.4
ATTENUATION
4.00
3.00
1.2
3.90
1.2
3.10
4.10
VSWR
VSWR
4.20
3.20
1.0
1.0
3 .30
1,000
2,000
3,000
4.30
1,000
4,000
1.6
VSWR
ATTENUATION (dB)
1.6
4.40
1.4
4.80
4,000
5.40
5.80
ATTENUATION
6.00
5.00
1.2
5.20
6.20
VSWR
VSWR
6.40
5.40
1.0
3,000
ATTENUATION (dB)
ATTENUATION
1.2
4,000
5.60
4.60
1.4
3,000
6 dB ATTENUATOR
5 dB ATTENUATOR
VSWR
2,000
FREQUENCY (MHz)
FREQUENCY (MHz)
1.0
5.60
1,000
2,000
3,000
4,000
6.60
1,000
2,000
FREQUENCY (MHz)
FREQUENCY (MHz)
83
SERIES A150
TYPICAL RF PERFORMANCE (Notes 2, 3 and 4)
8 dB ATTENUATOR
VSWR
1.6
10 dB ATTENUATOR
ATTENUATION (dB)
VSWR
7.40
1.6
ATTENUATION (dB)
9.40
7.60
9.60
ATTENUATION
ATTENUATION
1.4
7.80
1.4
8.00
1.2
10.00
8.20
8.40
1.0
9.80
1.2
10.20
VSWR
VSWR
10.40
8.60
1.0
1,000
2,000
3,000
10.60
4,000
1,000
FREQUENCY (MHz)
1.6
VSWR
ATTENUATION (dB)
1.6
15.40
1.4
1.0
19.80
20.00
1.2
16.20
16.40
ATTENUATION (dB)
19.40
ATTENUATION
ATTENUATION
15.80
16.00
1.2
4,000
19.60
15.60
1.4
3,000
20 dB ATTENUATOR
16 dB ATTENUATOR
VSWR
2,000
FREQUENCY (MHz)
20.20
VSWR
VSWR
20.40
1.0
16.60
1,000
2,000
3,000
20.60
1,000
4,000
FREQUENCY (MHz)
2,000
FREQUENCY (MHz)
THROUGH PATH
VSWR
1.6
ATTENUATION (dB)
0.0
INSERTION LOSS
0.2
1.4
0.4
0.6
1.2
0.8
1.0
VSWR
1.0
1.2
1,000
2,000
FREQUENCY (MHz)
84
3,000
4,00
3,000
4,000
SERIES A150
RF PERFORMANCE (-55°C to +85°C) (Notes 2, 3 and 4)
PARAMETER
MINIMUM
TYPICAL
MAXIMUM
UNITS
CONDITION
0.1
0.25
dB
DC-1 GHz
0.2
0.35
dB
1-2 GHz
0.3
0.55
dB
2-3 GHz
1.10
1.20
DC-1 GHz
1.20
1.25
1-2 GHz
1.25
1.30
2-3 GHz
1.20
1.25
DC-1 GHz
1.30
1.35
1-2 GHz
1.40
1.45
2-3 GHz
MINIMUM
TYPICAL
MAXIMUM
UNITS
CONDITION
0.95
1.0
1.05
dB
DC-1 GHz
0.925
1.0
1.075
dB
1-2 GHz
0.875
1.0
1.125
dB
2-3 GHz
Insertion loss
VSWR (Through path)
VSWR (Attenuated path)
ATTENUATION
1
2
3
4
5
6
8
10
16
20
1.9
2.0
2.1
dB
DC-1 GHz
1.85
2.0
2.15
dB
1-2 GHz
1.75
2.0
2.25
dB
2-3 GHz
2.85
3.0
3.15
dB
DC-1 GHz
2.77
3.0
3.23
dB
1-2 GHz
2.62
3.0
3.38
dB
2-3 GHz
3.8
4.0
4.2
dB
DC-1 GHz
3.7
4.0
4.3
dB
1-2 GHz
3.5
4.0
4.5
dB
2-3 GHz
4.75
5.0
5.25
dB
DC-1 GHz
4.62
5.0
5.38
dB
1-2 GHz
4.37
5.0
5.63
dB
2-3 GHz
5.7
6.0
6.3
dB
DC-1 GHz
5.55
6.0
6.45
dB
1-2 GHz
5.25
6.0
6.75
dB
2-3 GHz
7.88
8.0
8.12
dB
DC-1 GHz
7.76
8.0
8.24
dB
1-2 GHz
7.52
8.0
8.48
dB
2-3 GHz
9.85
10.0
10.15
dB
DC-1 GHz
9.7
10.0
10.3
dB
1-2 GHz
9.4
10.0
10.6
dB
2-3 GHz
15.76
16.0
16.24
dB
DC-1 GHz
15.52
16.0
16.48
dB
1-2 GHz
15.04
16.0
16.96
dB
2-3 GHz
19.8
20.0
20.2
dB
DC-1 GHz
19.6
20.0
20.4
dB
1-2 GHz
19.0
20.0
21.0
dB
2-3 GHz
85
SERIES A150
GENERAL PERFORMANCE (-55°C to + 85°C)
PARAMETER
MINIMUM
TYPICAL
MAXIMUM
UNITS
3.0
GHz
0.0
Operating frequency (Note 2)
Power (Notes 5 and 6)
1.0
Impedance
1,000,000
Contact Life expectancy
Watt
50
Ohms
10,000,000
Cycles
ELECTRICAL SPECIFICATIONS (-55°C to + 85°C, unless otherwise specified.)
PART NUMBER (Note 7)
A150-dB-5
Coil voltage VDC (Note 6)
A150-dB-12
A150-dB-15
A150-dB-26
Nom.
5
12
15
26.5
Max.
5.8
16.0
20.0
32.0
Coil resistance ohms ± 20%
@ 25°C
50
390
610
1,560
Pick-up voltage VDC max.
@ 25°C
3.8
9.0
11.3
18.0
Switching time ms (Note 8)
Max.
4.0
Typ.
2.0
Insulation resistance
1,000 MΩ typical (all mutually isolated points)
Dielectric strength
300 VRMS /60 Hz typical (at sea level)
TELEDYNE RELAYS PART NUMBERING SYSTEM
FOR A150 ATTENUATOR RELAYS
OUTLINE DIMENSIONS
CASE DETAIL
.335 MAX.
(8.51)
A150
.435 MAX.
(11.05)
Series
designator
.280
(7.11)
XX
Attenuation
value (dB)
–
XX
Nominal coil
voltage
.700 MIN.
(17.78)
+.002
.017 –.001 DIA.
(.43 +.05
–.03
–
NOTES:
)
.375 MAX
(9.53)
.200 ± .01
(5.08 ± 5.08)
3
5
2
6
1
0.31 REF.
(.79)
.150 ± .10 TYP.
(3.81 ± .25)
.475 MAX.
(12.07)
7
0.35 REF.
(.89)
1. Contacts will exhibit no contact chatter in excess of 10 µs or transfer in
excess of 1 µs.
2. Relays may be operated at higher frequencies with reduced RF performance.
3. Case should be electrically grounded.
4. Attenuation values shown are with reference to the through path
(low loss state).
5. Power handling for case temperatures of -55°C to +55°C is 1 Watt. derate
power handling 25 mW/°C above +55°C. Case measurement point is
adjacent to the relay tab.
6. Do not operate coil at maximum coil voltage continuously.
7. Insert attenuation value, see part numbering system.
8. Switching time includes bounce.
Dimensions shown are in inches (millimeters).
Terminal numbers shown are for reference only.
Leads 1 and 7 are grounded to the case.
©1996
TELEDYNE RELAYS
86
12525 Daphne Avenue
Hawthorne, California 90250