RF100 / RF103 Series

TELEDYNE RELAYS
SERIES
RF100
RF103
N
EW
HIGH REPEATABILITY
ULTRAMINIATURE
CENTIGRID® RELAY
BROADBAND
DC TO RF
SERIES
DESIGNATION
RELAY TYPE
RF100
Repeatable, RF, Centigrid® relay
RF103
Sensitive, repeatable, RF, Centigrid® relay
INTERNAL CONSTRUCTION
UNIFRAME
UPPER STATIONARY
CONTACT
ARMATURE
PERFORMANCE FEATURES
The ultraminiature RF100 and RF103 relays are
designed to provide improved RF signal repeatability
over the frequency range by balancing the aggregate
insertion loss elements of the relays’ design. Highly
suitable for use in attenuator and other RF circuits, the
RF 100 and RF103 feature:
MOVING CONTACT
LOWER STATIONARY
CONTACTS
• High repeatability.
• Broader bandwidth.
• Metal enclosure for EMI shielding.
• Ground pin option to improve case grounding.
• High isolation between control and signal paths.
• Highly resistant to ESD.
CONSTRUCTION FEATURES
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
-55 °C to +85 °C
Vibration (General Note 1)
10 G to 500 Hz
Shock (General Note 1)
30 G, 6 ms. half sine
Enclosure
Hermetically sealed
RF100
0.09 oz. (2.55 g) max.
RF103
0.16 oz. (4.50 g) max.
Weight
The following unique construction features and
manufacturing techniques provide excellent resistance
to environmental extremes and overall high reliability.
• Uni-frame motor design provides high magnetic
efficiency and mechanical rigidity.
• Minimum mass components and welded construction
provide maximum resistance to shock and vibration.
• Dual weld projection provides increased design
robustness.
• Advanced cleaning techniques provide maximum
assurance of internal cleanliness.
• Gold plated precious metal alloy contacts ensure
reliable switching.
• Hermetically sealed .
Solderable leads.
SERIES RF100 and RF103
TYPICAL RF CHARACTERISTICS (Notes 1, 2 and 3)
INSERTION LOSS AND VSWR CHARACTERISTICS RF100 and RF103 NORMALLY CLOSED CONTACTS
2.0
INSERTION LOSS
1.9
-0.4
1.8
-0.6
1.7
-0.8
1.6
-1.0
1.5
1.2
1.4
-1.4
1.3
VSWR
INSERTION LOSS (dB)
0.0
-0.2
1.2
-1.6
-1.8
1.1
VSWR
1.0
-2.0
.0003
1.0
2.0
4.0
3.0
FREQUENCY (GHz)
5.0
6.0
INSERTION LOSS AND VSWR CHARACTERISTICS RF100 and RF103 NORMALLY OPEN CONTACT
2.0
INSERTION LOSS
1.9
-0.4
1.8
-0.6
1.7
-0.8
1.6
-1.0
1.5
1.2
1.4
-1.4
1.3
VSWR
INSERTION LOSS (dB)
0.0
-0.2
1.2
-1.6
VSWR
-1.8
1.1
1.0
-2.0
.0003
1.0
2.0
3.0
4.0
5.0
6.0
FREQUENCY (GHz)
ISOLATION CHARACTERISTICS RF100 AND RF103 RELAYS
ISOLATION CONTACT TO CONTACT (NOTE 5)
0
-10
-10
ISOLATION (dB)
ISOLATION (dB)
ISOLATION POLE TO POLE (NOTE 4)
0
-20
-30
-40
-50
-30
-40
-50
-60
.0003
-20
-60
1.0
2.0
3.0
4.0
FREQUENCY (GHz)
5.0
6.0
.0003
1.0
2.0
3.0
4.0
5.0
6.0
FREQUENCY (GHz)
RF Notes:
1. Test conditions: a. Fixture: .031” copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors. (RT/duroid® is a registered
trademark of Rogers Corporation).
b. Relay header is in contact with but not soldered to ground plane or connected to ground via ground pin.
c. Test performed at room ambient temperature.
d. Terminals not tested were terminated with 50 ohm load.
e. Contact signal level: 20 dBm.
2. Data presented herein represents typical characteristics and is not intended for use as specification limits.
3. Data is per pole.
4. Data is the average from readings taken when the relay is de-energized and energized. Measurement points are from pins 1 and 3 to
pins 5 and 7 (de-energized) and pins 1 and 2 to pins 6 and 7 (energized).
5.Data is the average from readings taken when the relay is de-energized and energized. Measurement points are from pins 1, 3 to 2 and
pins 5,7 to 6 (de-energized) and pins 1,2 to 3 and pins 6,7 to 5 (energized).
SERIES RF100 and RF103
TYPICAL RF INSERTION LOSS REPEATABILITY CHARACTERISTICS (Notes 1 and 2)
NORMALLY CLOSED
100
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2
% TOTAL NUMBER RECORDED TEST CYCLES
% TOTAL NUMBER RECORDED TEST CYCLES
REPEATABILITY CHARACTERISTICS RF100 RELAYS
NORMALLY OPEN
100
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2
REPEATABILITY (dB)
REPEATABILITY (dB)
NORMALLY CLOSED
100
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2
REPEATABILITY (dB)
% TOTAL NUMBER RECORDED TEST CYCLES
% TOTAL NUMBER RECORDED TEST CYCLES
REPEATABILITY CHARACTERISTICS RF103 RELAYS
NORMALLY OPEN
100
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2
REPEATABILITY (dB)
RF Insertion Loss Repeatability Notes
1. Test conditions: a. Fixture: .031” copper clad, reinforced PTFE, RT/duroid 6002® with SMA connectors. (RT/duroid® is a registered
trademark of Rogers Corporation).
b. Relays header is connected to but not soldered to ground plane nor connected via ground pin.
c. Test performed at room ambient temperature.
d. Contact signal level: 20 dBm.
2. Data presented herein represents typical characteristics and is not intended to be used as specification limits.
3. Insertion loss repeatability measured over frequency range from .3 MHz to 4 GHz.
SERIES RF100 and RF103
GENERAL ELECTRICAL SPECIFICATIONS (@25°C)
Contact arrangement
DPDT
Rated duty
Continuous
Contact resistance
.100 ohm max. initial (measured 1/8” from the header)
Contact load rating
Low level: 10 to 50 µA, 10 to 50 mV
Contact life rating
10,000,000 cycles typical at low level
RF100: 450 mW typical @ nominal rated voltage
RF103: 200 mW typical @ nominal rated voltage
Coil operating power
RF100
4.0 ms. max.
RF103
6.0 ms. max.
RF100
3.0 ms. max.
RF103
3.0 ms. max.
Operate time
Release time
Intercontact capacitance
0.4 pF typical
Insulation resistance
1,000 MΩ min. (between mutually isolated terminals)
Dielectric strength
350 VRMS / 60 Hz @ atmospheric pressure
DETAILED ELECTRICAL SPECIFICATIONS (@ 25°C)
BASE PART NUMBERS
RF100-5
RF103-5
RF100-12
RF103-12
Coil voltage, nominal, VDC
5.0
12.0
RF100
50
390
RF103
100
800
3.6
9.0
Coil resistance, ohms ± 20%
Pick-up voltage max, VDC
OUTLINE DIMENSIONS
.031 (.79)
REF.
7
8
4
.335
(8.51)
SQ. MAX.
H DIMENSION
MAX.
.035 (.89)
REF.
2
6
5
1
.375
(9.53)
SQ. MAX.
0.100 ± 0.010
(2.54 ± 0.25)
H
3
TERMINAL NUMBERING
SCHEMATIC
• TERMINAL NUMBERING AND SCHEMATIC ARE AS VIEWED FROM THE TERMINALS.
• DIMENSIONS ARE IN INCHES (MILLIMETERS).
• SCHEMATIC AND EXTERNAL DIMENSIONS SHOWN WITHOUT GROUND PINS.
• TO ORDER THE CASE GROUND OPTION, AFTER THE SERIES DESIGNATOR, ADD “Y” TO
THE PART NUMBER FOR TAB POSITION OR “Z” TO THE PART NUMBER FOR CENTER
POSITION .
EXAMPLE: RF1##Y-COIL VOLTAGE
RF100
.290
(7.37)
RF103
.395
(10.03)
.75 (19.05) MIN.
+.002
.017 -.001
( .43 +.05
-.03
)
EXTERNAL DIMENSIONS
GENERAL NOTES
1. Relays will exhibit no contact chatter in excess of 10 µs or transfer in excess of 1 µs.
©1998
TELEDYNE RELAYS
12525 Daphne Ave.
Hawthorne, CA 90250
(213) 777-0077
http://www.teledynerelays.com.