LoopBack Relay Datasheet.indd

Series LB363/GLB363
LoopBack Relay
Up to 12Gbps
LoopBack Relay
LB363 Series
GLB363 Series
SERIES
DESIGNATION
LB363
GLB363
RELAY TYPE
LoopBack Relay, Sensitive Coil
LoopBack Relay, Ground Shield, Surface-Mount (Stub Leads), Sensitive Coil
DESCRIPTION
The LoopBack Series relay combines two DPDT
electromechanical relays in one package that includes an
internal bypass path for Automated Test Equipment (ATE)
applications. The LoopBack combines the technology of two
Teledyne RF/GRF300 Series relays which eliminates the need
for external PCB traces in loop back test applications. This
innovation results in superior signal integrity and RF
performance, while taking minimal board space. The
LB/GLB363 Series is designed for digital signaling application
and provides excellent signal integrity up to 12 Gbps data
rates.
The LoopBack relay is available with two different internal
paths: Through and AC Bypass. The Through version provides
a loop back path across high performance contact material,
while the AC Bypass Model adds a coupling capacitor across
each loop back path. The internal in-line capacitors allow you
to eliminate the footprints for external components, while
performing AC bypass functions internal to the relay. The
capacitors used feature excellent signal integrity as well as
low loss high frequency performance.
receiver of the DUT. The double pole design of the LoopBack
relay is perfectly suited for differential signaling, allowing
relay component to provide transmit and receive signals and
their inversions to the DUT or through the bypass path.
The internal structure of the LoopBack relay reduces the
number of discontinuities and shortens the signal path
during loop back testing, providing lower insertion loss and
higher signal integrity performance than two RF/GRF303
Series relays. In the normally closed mode (de-energized) the
LoopBack relay provides four normally closed contacts. When
energized, the moving contacts are connected together
across the loop back structure to provide two through paths.
The normally closed contacts have similar performance to
RF/GRF303 Series relays.
In addition to the thru-hole mount, the LoopBack Series relay
is available in through hole surface mount stub leads with a
ground shield. The surface mount ground shield used in the
stub lead provides improved high data rate and high
frequency performance, as well as improved repeatability.
Upon request, various ground pin configurations for through
lead models are available.
A typical loop-back load board application uses the Device
Under Test (DUT) to test itself. In this method, the transmitter
from the DUT is connected through a loop back path to the
ENVIRONMENTAL AND PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
Storage
–65°C to +125°C
Operating
–55°C to +85°C
Vibration
(General Note 1)
Weight
© 2011 TELEDYNE RELAYS
LB363
Enclosure
Hermetically sealed
10 g’s to 500 Hz
Shock
(General Note 1)
30 g’s,
6ms half sine
0.16 oz. (4.53g) max.
GLB363
0.18 oz. (5.10g) max.
(800) 284-7007 • www.teledynerelays.com
LB363/GLB363 Page 1
Series LB363/GLB363
LoopBack Relay
Up to 12Gbps
SERIES LB363/GLB363
TYPICAL RF Characteristics (See RF Notes on next page)
AC Bypass Path (thru Capacitor) - Insertion Loss
AC Bypass Path (thru Capacitor) - VSWR
0.00
5.00
-0.50
4.50
4.00
-1.50
3.50
-2.00
VSWR
Insertion Loss (dB)
-1.00
-2.50
-3.00
3.00
2.50
-3.50
2.00
-4.00
1.50
-4.50
-5.00
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
1.00
0.00
8.00
1.00
2.00
3.00
Frequency (GHz)
4.00
5.00
6.00
7.00
8.00
Frequency (GHz)
AC Bypass Path (thru Capacitor) - Isolation
0.00
Isolation (dB)
-10.00
-20.00
-30.00
-40.00
-50.00
-60.00
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
Frequency (GHz)
Normally Closed RF Performance
Isolation Pole to Pole (RF Note 5)
0
-10
-10
-20
-20
Isolation (dB)
Isolation (dB)
Isolation Across Contacts (RF Note 4)
0
-30
-40
-30
-40
-50
-50
-60
-60
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
0
6000
500
1000
1500
2000
2.0
-0.2
1.8
-0.4
1.6
VSWR
Insertion Loss (dB)
3000
3500
4000
4500
5000
5500
6000
VSWR (RF Note 6)
Insertion Loss (RF Note 6)
0
-0.6
-0.8
-1
0
2500
Frequency (MHz)
Frequency (MHz)
1.4
1.2
1.0
500
1000
1500
2000
2500
3000
3500
Frequency (MHz)
LB363/GLB363 Page 2
4000
4500
5000
5500
6000
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
Frequency (MHz)
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2011 TELEDYNE RELAYS
Series LB363/GLB363
LoopBack Relay
Up to 12Gbps
SERIES LB363/GLB363
GENERAL ELECTRICAL SPECIFICATIONS (@ 25 ºC unless otherwise noted)
Contact Arrangement
Special (See Schematic on page 5)
Rated Duty
Continuous
Contact Resistance
0.200 Ω max. initial (measured 1/8" from the header)
Contact Load Rating
Resistive: 1Amp/28Vdc
Low level: 10 to 50 μA, 10 to 50 mV
Contact Life Ratings
5,000,000 cycles (typical) at low level
Operate Time
4.0 mS max.
Release Time
3.0 mS max.
Insulation Resistance
1,000 MΩ min. between mutually isolated terminals
Dielectric Strength
350 Vrms (60 Hz) @ atmospheric pressure
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
LB363-100-5
GLB363-100-5
LB363-100-12
GLB363-100-12
5.0
12.0
Coil Resistance (Ohms ±20%)
56
400
Pick-up Voltage (Vdc max.)
3.6
9.0
Coil Operating Power (mW)
450
360
BASE PART NUMBERS
Coil Voltage, Nominal (Vdc)
RF NOTES
a. Fixture: .031" copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors.
(RT/duroid® is a registered trademark of Rogers Corporation.)
b. Room ambient temperature.
c. Terminals not tested were terminated with 50-ohm load.
d. Contact signal level: –10 dBm.
e. No. of test samples: 4.
Data presented herein represents typical characteristics and is not intended for use as specification limits.
Data is per pole, except for pole-to-pole data.
Data is the average from readings taken on all open contacts.
Data is the average from readings taken on poles with coil energized and de-energized.
Data is the average from readings taken on all closed contacts.
Test fixture effect de-embedded from frequency and time response data.
1. Test conditions:
2.
3.
4.
5.
6.
7.
© 2011 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
LB363/GLB363 Page 3
Series LB363/GLB363
LoopBack Relay
Up to 12Gbps
SERIES LB363/GLB363
TYPICAL Single-Ended Signal Integrity Characteristics
AC Bypass Path
+100 mV
0V
-100 mV
0 ps
40 ps
80 ps
120 ps
160 ps
Eye Height
Eye Width
JitterP-P
254.3 mV
88.64 ps
8.89 ps
200 ps
SERIES LB363/GLB363
TYPICAL Differential Signal Integrity Characteristics
AC Bypass Path
+200 mV
0V
-200 mV
0 ps
LB363/GLB363 Page 4
40 ps
80 ps
120 ps
160 ps
Eye Height
Eye Width
JitterP-P
492.1 mV
84.29 ps
15.55 ps
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
200 ps
© 2011 TELEDYNE RELAYS
Series LB363/GLB363
LoopBack Relay
Up to 12Gbps
SERIES LB363
OUTLINE DIMENSIONS
12
(Optional)
18
(Optional)
16
2
14
4
13
5
11
(Optional)
7
9
CAPACITOR
(Optional)
SCHEMATIC - TERMINAL VIEW
U.S. PATENT PENDING
PIN NUMBERS ARE FOR REFERENCE
ONLY, NOT MARKED ON RELAY
NOTES:
1.
DIMENSIONS ARE IN INCHES. METRIC EQUIVALENTS
(MILLIMETERS) ARE SHOWN IN [ X.XX ].
2.
TOLERANCE (UNLESS OTHERWISE SPECIFIED):
±.010 INCH [±0.025 mm]
CONTACT ARRANGEMENT
N.C. SIDE (COILS DE-ENERGIZED):
4PST, NORMALLY CLOSED
N.O. SIDE (COILS ENERGIZED):
DPST, NORMALLY OPEN,
DOUBLE MAKE
Teledyne Part Numbering System for LoopBack Relays
LB363 YZ - 100 - 5
Relay Series
Ground Pin (Optional)
Y = Center Position
Z = Center Position
Blank = No ground pin
© 2011 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
Coil Voltage
5 = 5V
12 = 12V
Capacitance
100 = 100nF
LB363/GLB363 Page 5
Series LB363/GLB363
LoopBack Relay
Up to 12Gbps
SERIES GLB363
OUTLINE DIMENSIONS
RF GROUND SHIELD
(SEE NOTE 3.)
18
16
2
14
4
13
5
11
7
9
CAPACITOR
SCHEMATIC - TERMINAL VIEW
PIN NUMBERS ARE FOR REFERENCE
ONLY, NOT MARKED ON RELAY
NOTES:
1.
DIMENSIONS ARE IN INCHES. METRIC EQUIVALENTS
(MILLIMETERS) ARE SHOWN IN [ X.XX ].
2.
TOLERANCE (UNLESS OTHERWISE SPECIFIED):
±.010 INCH [±0.025 mm]
3.
FOR BEST RF PERFORMANCE, SOLDER BOTTOM OF RF
GROUND SHIELD TO RF GROUND PLANE OF PC BOARD.
CONTACT ARRANGEMENT
N.C. SIDE (COILS DE-ENERGIZED):
4PST, NORMALLY CLOSED
N.O. SIDE (COILS ENERGIZED):
DPST, NORMALLY OPEN,
DOUBLE MAKE
Teledyne Part Numbering System for LoopBack Relays
GLB363 - 100 - 5
Relay Series
Coil Voltage
5 = 5V
12 = 12V
Capacitance
100 = 100nF
LB363/GLB363 Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2011 TELEDYNE RELAYS