SQ24D25 - Teledyne Relays

Series SQ
Quad Output 25A, 280 Vac
DC Solid-State Relay
FEATURES/BENEFITS
• Four independently controlled solid-state relays in an industry standard package.
• Tight zero-cross window for low EMI
• Constant current input for low current draw
• Faston terminals
• High-power switching
• Optical isolation ensures complete protection of the control circuit from load transients
• Heating & motor control, industrial & process controls, on/off control of AC equipment
• UL recognized (UL File Number: E128555)
Part Number
Description
SQ24D25
25A, 240 Vac Solid-State Relay
SQ24R25
25A, 240 Vac Solid-State Relay
MECHANICAL SPECIFICATION
0.0315 (0.8)
Part Number Explanation
SQ
24
D
1.299 (33) MAX
25
0.772 (19.6)
fl 0.185 (4.7)
Max
Units
3
4
32
40
Vdc
Vdc
Vdc
D1
D2
1.874 (47.6)
B2
.78 (19.8)
1.378 (35)
1.752 (44.5)
Vdc
Reverse Voltage
32
Vdc
TYPICAL APPLICATION
load
24-280 Vac
A2
1
B2
Must Turn-Off Voltage
CONTROL CHARACTERISTIC
- DC section C
+DC commun
-DC section D
B1
4.3
-DC section B
C2
Figure 1
Input Current Range See Figure 2
Typical Turn-On Voltage
C1
-DC section A
B1
wEIgHT: 3.175 oz. (90g)
TOLERANCES: –0.01 (–0.3)
A2
load
24-280 Vac
A1
Control Range
SQ24D25
SQ24R25
Min
A1
0.2047 (5.2)
INPUT (CONTROL) SPECIFICATIONS
0.25 (6.35)
ELECTRICAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
2.283 (58)
NOTES
1) Line Voltage (nominal): 24 = 240 Vac
2) Switch Type: D = Zero-cross turn-on; R = Random turn-on
3) Control LED model available. Contact factory.
1.598 (40.6)
Switch Type2
Line Voltage1
Output Current – Amps
0.3425 (8.7)
Series
7
6
5
C2
C1
load
24-280 Vac
D2
10
9
8
D1
Input Current (mA)
12
11
load
24-280 Vac
-DC section C
-DC section A
+DC common
-DC section B
-DC section D
4
3
2
1
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Figure 3
Control Voltage (V)
Figure 2
© 2007 Teledyne Relays
(800) 284-7007 • www.teledynerelays.com ❖ +44 (0) 1236 453124 • www.teledyne-europe.com
SQ Page 1
SQ\092007\Q1
Series SQ
Quad Output 25A, 280 Vac
DC Solid-State Relay
THERMAL CHARACTERISTICS
140
4 relays
140
0.55°C/w
Power Dissipated (W)
120
120
3 relays
100
80
2 relays
0.95°C/w
100
80
1.6°C/w
60
60
2.2°C/w
40
40
1 relay
20
20
without Heat Sink
0
0
0 2
4
6
8 10 12 14 16 18 20 22 24 26
0
10
20
Load Current (Arms)
30
40
50
60
70
80
90
100
Ambient Temperature (°C)
Figure 4
ELECTRICAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
SURGE CURRENT
250
OUTPUT (LOAD) SPECIFICATIONS
200
Min
Max
Units
12
280
Vrms
Peak Voltage
600
Vpeak
Load Current Range
(See Figure 4)
25
Arms
Operating Range
.005
Apeak
Non-Repetitive
150
100
50
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
10
t(s)
Figure 5
Maximum Surge Current Rating
(Non-repetitive, see Figure 5)
240
A
On-State Voltage Drop
1.2
V
Zero-Cross Window
±25
V
Off-State Leakage Current (60Hz)
0.5
mA
Turn-On Time
SQ24D25
SQ24R25
8.3
0.1
ms
ms
Turn-Off Time
8.3
µs
Off-State dv/dt
500
V/µs
Operating Frequency Range
440
Hz
288
A 2s
47
I2t for Match Fusing (<8.3ms)
NOTES
1. Electrical specifications at 25°C unless otherwise noted.
2. Control LED models available. Contact factory.
3. For 800Hz applications, contact factory.
4. For additional/custom options, contact factory.
OPTIONAL ADD-ONS
Please order add-ons separately:
• -12 — Thermal pad installed
GENERAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
ENVIRONMENTAL SPECIFICATIONS
Min
Max
Units
Operating Temperature
–40
+100
°C
Storage Temperature
–40
+100
°C
Input-Output Isolation
4000
Vrms
Output-Case Isolation
2500
Vrms
Rated Impulse Voltage
4000
V
SQ Page 2
Specifications are subject to change without notice
© 2007 Teledyne Relays
SQ\092007\Q1