641-1 - Teledyne Relays

Series 641
Random Turn “On” & Transformer Isolated
AC Solid-State Relay
ELECTRICAL SPECIFICATIONS
25°C UNLESS OTHERWISE SPECIFIED)
INPUT (CONTROL) SPECIFICATIONS
Parameter
Min
Max
Units
Control Voltage Range (See Figure 1)
4.0
10
Vdc
16
mAdc
Input Current at 5V Control Voltage
Must Turn-On Voltage
4.0
Vdc
Must Turn-Off Voltage
0.5
Vdc
OUTPUT (LOAD) SPECIFICATIONS
Parameter
Part
Min
Max
Load Voltage Rating
641-1
0
140
641-2
0
250
Units
Vrms
Output Current Rating (See Figure 3, Note 1) 0.005
0.5
Arms
Frequency range
70
Hz
641-1
200
Vpeak
641-2
400
Vpeak
1.5
Vrms
(Non-repetitive 16 ms mac. See Figure 2, Note 2)
5.0
A
Turn-On Time (60 Hz)
20
µs
Turn-Off Time (60 Hz)
8.3
ms
Leakage Current (Rated Voltage at 100°C)
1.0
mArms
Off-State dV/dt (Without RC Snubber, Typical)
50
V/µs
Insulation Resistance (Input to Output at 500 Vdc)
109
Ohms
Over Voltage Rating
0.1
On-State Voltage Drop at Rated Voltage
Surge Current Rating
Dielectric Strength (Input to Output)
2500
Vac
Capacitance (Input to Output)
5
pF
Junction Temperature (TJ)
100
°C
641 14
FEATURES/BENEFITS
• Fast Switching Speed:
Where speed is important
• Floating Output: Eliminates
ground loops and signal
ground noise
• Random Turn On: For
pulse width modulation
• Low Off State Leakage: For
high off-state impedance
• Switches High Voltages:
To 250 Vrms
• Switches High Currents:
To 0.5 Arms
• High Noise Immunity:
Control signals isolated
from switching noise
• High Dielectric Strength:
For safety and for
protection of control and
signal level circuits
DESCRIPTION
The Series 641 features
random turn-on for controlling
AC loads with a triac output
rated at 0.5 amp up to 50˚C
ambient without a heat sink. A
high frequency input oscillator
with isolation transformer
coupled directly to the triac
gate provides the added
capability of driving very low
current AC loads down to 5 mA.
Internal design employs a
unique patented lead frame
construction molded in a 14-pin
DIP package.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2002 TELEDYNE RELAYS
641\072002\Q1
Series 641
CHARACTERISTIC CURVES
MECHANICAL SPECIFCATIONS
TYPICAL 641 INTERFACE
NOTES:
1. UL rated at 0.5 Arms for motor starting and incandescent
lamp control.
2. Triac may lose blocking capability during and after surge until
TJ falls below 125°C maximum.
© 2002 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
641 15
641\072002\Q1