Series FB Low Leakage, High Voltage, Bi-Directional & DC Output Bi-Directional Solid-State Relay Part Number* DESC Drawing Relay Description Number FB00CDW FB00CDY 89116-006 Solid State Relay ±1.0 A @ ±80 Vdc Output 89116-002 Solid State Relay ±0.5 A @ ±180 Vdc Output 89116-004 Solid State Relay ±250 mA @ ±350 Vdc Output FB00FCW FB00FCY FB00KBW FB00KBY * The Y suffix denotes parameters tested to MIL-PRF-28750 specifications. The W suffix denotes parameters tested to Teledyne specifications. BLOCK DIAGRAM FEATURES • High voltage output • Extremely low leakage current (200 nanoamperes) • Bi-directional Power FET output • Optical isolation • Fast switching speed • Adjustable turn-on times • Low profile 6-pin mini-DIP • Built and tested to the requirements of MIL-PRF-28750 APPLICATIONS • • • • Ideal for Automatic Test Equipment (ATE) Telecommunications applications High-voltage instrumentation systems High-speed switching with low EMI DESCRIPTION MECHANICAL SPECIFICATIONS DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS) FB 90 The Series FB relay is an advanced solidstate bi-directional relay designed specifically for high-speed switching in A.T.E. systems. These devices utilize Teledyne state-of-theart solid-state circuit technology and manufacturing techniques to provide high reliability, low life cycle cost and exceptional switch performance. Each device is uniquely characterized by its switching function. The FB00FC is a power instrumentation relay with low ON resistance and leakage current. The FB00KB is a high-voltage instrumentation relay with a quarter ampere current rating. The FB00CD is a power relay with a current rating of 1 ampere and an ON resistance of 0.4 ohm. The FB solid-state relay has very fast turn on times of under 1 msec and can also be controlled and adjusted with the input current for specific requirements. Other features include optical coupling and full military temperature operating range for extreme applications. Optical coupling minimizes EMI generation and isolates and protects delicate input logic circuits from output voltage transients. These devices are packaged and hermetically sealed in a low-profile metal 6- pin mini-DIP with lead spacing on 0.300 centers for standard mounting configurations. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS FB\072002\Q1 Series FB ELECTRICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS (-55°C TO 120°C Ambient Temperature Unless Otherwise Noted) INPUT (CONTROL) SPECIFICATION (See Note 1) Min Rated Input Current Typ 10 Input Voltage Drop @ 25 mA Max Units 25 mAdc 3.25 Vdc Max Units Operating -55 +120 °C Storage -55 +125 °C 10 2000 Hz Constant Acceleration 5000 g Shock, 0.5 ms pulse 1500 g Temperature Vibration, 100 g Continuous Input Current -55°C < TA < 105°C 10 50 mAdc 105°C < TA < 120°C 10 25 mAdc Reverse Voltage Protection -5 Vdc Input Current (Guaranteed Off) 10 µAdc Input Current (Guaranteed On) Min 10 Turn-Off Voltage mA 1.5 Vdc OUTPUT (LOAD) SPECIFICATIONS BI-DIRECTIONAL AND AC CONFIGURATIONS (PIN 4 TO PIN 6), SEE NOTE 2 FB00CD Min Continuous Load Current (See Fig. 3 & Note 5) Max FB00FC Min Max FB00KB Min Max Units ±1.0 ±0.5 ±0.25 Adc -55°C < TA < +25°C ±200 ±200 ±200 nAdc +25°C < TA < 120°C ±20 ±20 ±20 µAdc ±0.75 ±1.0 ±2.4 Vdc Continuous Operating Load Voltage ±80 ±180 ±350 Vdc Transient Blocking Voltage (5 s max.) ±90 ±180 ±360 Vdc ON Resistance Rds (on) at TJ = 25°C 0.6 1.0 8.0 Ohm Turn-On Time @ IIN = 25 mA (See Fig. 2 and 5) 800 800 500 µs Turn-Off Time (See Fig. 5) 500 500 500 µs Leakage Current @ Vload = max. operating voltage Output Voltage Drop ILOAD = 100 mAdc (See Fig. 4 & Note 6) dV/dt 100 100 100 V/µs Load Surge Current (See Note 3) ±3.5 ±1.75 ±0.875 Adc DC Offset Voltage 100 100 100 µV Output Capacitance at 25 Vdc, 1 MHz 325 250 100 pF © 2002 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com FB 91 FB\072002\Q1 Series FB OUTPUT (LOAD) SPECIFICATIONS DC Configuration (Pins 4 and 6 connected together referenced to Pin 5) (See Notes 2 & 7) FB00CD Min Continuous Load Current (See Fig. 3 & Note 5) Max FB00FC Min Max FB00KB Min Max Units 2.0 1.0 0.5 Adc -55°C < TA < +25°C 400 400 400 nAdc +25°C < TA < 120°C 40 40 40 µAdc Output Voltage Drop 0.4 0.5 1.8 Vdc Continuous Operating Load Voltage 80 180 350 Vdc Transient Blocking Voltage (5 s max.) 90 180 360 Vdc ON Resistance Rds (on) at TJ = 25°C 0.15 0.25 2.0 Ohm Turn-On Time @ IIN = 25 mA (See Fig. 2 and 5) 800 800 500 µs Turn-Off Time (See Fig. 5) 500 500 500 µs Load Surge Current (See Note 3) 7.0 3.5 1.75 Adc Output Capacitance at 25 Vdc, 1 MHz 650 500 200 pF Leakage Current @ Vload = max. operating voltage ILOAD = 100 mAdc (See Fig. 4 & Note 6) OUTPUT (LOAD) SPECIFICATIONS FB00CD All Configurations Min Input to Output Capacitance Max FB00FC Min 5 Max FB00KB Min 5 Max Units 5 pF Dielectric Strength 500 500 500 Vac Insulation Resistance @ 500 Vdc 109 109 109 Ohm Output Junction Temperature @ ILOAD = Imax rated 125 125 125 °C Maximum Junction Temperature (TJ Max.) 150 150 150 °C Thermal Resistance Junction to Ambient (θJA) 110 110 110 °C/W Thermal Resistance Junction to Case (θJC) 20 20 20 °C/W FB 92 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS FB\072002\Q1 Series FB A) BI-DIRECTIONAL AND DC CONFIGURATION (SEE NOTE 4) LOAD CURRENT DERATING CURVE FIGURE 3 B) DC CONFIGURATION (SEE NOTE 4) WIRING CONFIGURATIONS FIGURE 1 INPUT CURRENT VS TURN-ON TIME FIGURE 2 NORMALIZED ON RESISTANCE VS JUNCTION TEMPERATURE. FIGURE 4 (SEE NOTE 6) NOTES: 1. 2. 3. 4. 5. 6. 7. Series resistor required to limit input current to 50 mA max. The rated input current is 25 mA for all tests unless otherwise specified. Surge current is specified for 25°C, 10 cycles maximum at a 1 Hz repetition rate with 10% duty cycle and 0.1 s. duration. Relays may drive loads connected to either positive or negative referenced power supply lines. Inductive loads must be diode suppressed. Continuous load current is rated under the condition of still air. To calculate the maximum ON resistance for a given junction temperature, find the normalized ON resistance factor (NR) from Figure 4. Calculate the new ON resistance as follows: R(ON) = NR X R(ON) @ 25°C Relays are tested in the bi-directional configuration only. © 2002 TELEDYNE RELAYS OUTPUT TURN-ON AND OFF TIMING FIGURE 5 (800) 284-7007 • www.teledynerelays.com FB 93 FB\072002\Q1