FB00CDY - Teledyne Relays

Series FB
Low Leakage, High Voltage, Bi-Directional & DC Output
Bi-Directional Solid-State Relay
Part
Number*
DESC Drawing Relay Description
Number
FB00CDW
FB00CDY
89116-006
Solid State Relay
±1.0 A @ ±80 Vdc Output
89116-002
Solid State Relay
±0.5 A @ ±180 Vdc Output
89116-004
Solid State Relay
±250 mA @ ±350 Vdc Output
FB00FCW
FB00FCY
FB00KBW
FB00KBY
* The Y suffix denotes parameters tested to MIL-PRF-28750
specifications. The W suffix denotes parameters tested to Teledyne
specifications.
BLOCK DIAGRAM
FEATURES
• High voltage output
• Extremely low leakage current
(200 nanoamperes)
• Bi-directional Power FET output
• Optical isolation
• Fast switching speed
• Adjustable turn-on times
• Low profile 6-pin mini-DIP
• Built and tested to the requirements of
MIL-PRF-28750
APPLICATIONS
•
•
•
•
Ideal for Automatic Test Equipment (ATE)
Telecommunications applications
High-voltage instrumentation systems
High-speed switching with low EMI
DESCRIPTION
MECHANICAL SPECIFICATIONS
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
FB 90
The Series FB relay is an advanced solidstate bi-directional relay designed specifically
for high-speed switching in A.T.E. systems.
These devices utilize Teledyne state-of-theart solid-state circuit technology and
manufacturing techniques to provide high
reliability, low life cycle cost and exceptional
switch performance. Each device is uniquely
characterized by its switching function. The
FB00FC is a power instrumentation relay with
low
ON
resistance
and
leakage
current. The FB00KB is a high-voltage
instrumentation relay with a quarter ampere
current rating. The FB00CD is a power relay
with a current rating of 1 ampere and an ON
resistance of 0.4 ohm. The FB solid-state
relay has very fast turn on times of under 1
msec and can also be controlled and adjusted
with the input current for specific
requirements. Other features include optical
coupling and full military temperature
operating range for extreme applications.
Optical coupling minimizes EMI generation
and isolates and protects delicate input logic
circuits from output voltage transients. These
devices are packaged and hermetically
sealed in a low-profile metal 6- pin mini-DIP
with lead spacing on 0.300 centers for
standard mounting configurations.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2002 TELEDYNE RELAYS
FB\072002\Q1
Series FB
ELECTRICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
(-55°C TO 120°C Ambient Temperature Unless Otherwise Noted)
INPUT (CONTROL) SPECIFICATION
(See Note 1)
Min
Rated Input Current
Typ
10
Input Voltage Drop @ 25 mA
Max Units
25
mAdc
3.25
Vdc
Max
Units
Operating
-55
+120
°C
Storage
-55
+125
°C
10
2000
Hz
Constant Acceleration
5000
g
Shock, 0.5 ms pulse
1500
g
Temperature
Vibration, 100 g
Continuous Input Current
-55°C < TA < 105°C
10
50
mAdc
105°C < TA < 120°C
10
25
mAdc
Reverse Voltage Protection
-5
Vdc
Input Current (Guaranteed Off)
10
µAdc
Input Current (Guaranteed On)
Min
10
Turn-Off Voltage
mA
1.5
Vdc
OUTPUT (LOAD) SPECIFICATIONS
BI-DIRECTIONAL AND AC CONFIGURATIONS (PIN 4 TO PIN 6), SEE NOTE 2
FB00CD
Min
Continuous Load Current (See Fig. 3 & Note 5)
Max
FB00FC
Min
Max
FB00KB
Min
Max
Units
±1.0
±0.5
±0.25
Adc
-55°C < TA < +25°C
±200
±200
±200
nAdc
+25°C < TA < 120°C
±20
±20
±20
µAdc
±0.75
±1.0
±2.4
Vdc
Continuous Operating Load Voltage
±80
±180
±350
Vdc
Transient Blocking Voltage (5 s max.)
±90
±180
±360
Vdc
ON Resistance Rds (on) at TJ = 25°C
0.6
1.0
8.0
Ohm
Turn-On Time @ IIN = 25 mA (See Fig. 2 and 5)
800
800
500
µs
Turn-Off Time (See Fig. 5)
500
500
500
µs
Leakage Current @ Vload = max. operating voltage
Output Voltage Drop
ILOAD = 100 mAdc (See Fig. 4 & Note 6)
dV/dt
100
100
100
V/µs
Load Surge Current (See Note 3)
±3.5
±1.75
±0.875
Adc
DC Offset Voltage
100
100
100
µV
Output Capacitance at 25 Vdc, 1 MHz
325
250
100
pF
© 2002 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
FB 91
FB\072002\Q1
Series FB
OUTPUT (LOAD) SPECIFICATIONS
DC Configuration (Pins 4 and 6 connected together referenced to Pin 5) (See Notes 2 & 7)
FB00CD
Min
Continuous Load Current (See Fig. 3 & Note 5)
Max
FB00FC
Min
Max
FB00KB
Min
Max
Units
2.0
1.0
0.5
Adc
-55°C < TA < +25°C
400
400
400
nAdc
+25°C < TA < 120°C
40
40
40
µAdc
Output Voltage Drop
0.4
0.5
1.8
Vdc
Continuous Operating Load Voltage
80
180
350
Vdc
Transient Blocking Voltage (5 s max.)
90
180
360
Vdc
ON Resistance Rds (on) at TJ = 25°C
0.15
0.25
2.0
Ohm
Turn-On Time @ IIN = 25 mA (See Fig. 2 and 5)
800
800
500
µs
Turn-Off Time (See Fig. 5)
500
500
500
µs
Load Surge Current (See Note 3)
7.0
3.5
1.75
Adc
Output Capacitance at 25 Vdc, 1 MHz
650
500
200
pF
Leakage Current @ Vload = max. operating voltage
ILOAD = 100 mAdc (See Fig. 4 & Note 6)
OUTPUT (LOAD) SPECIFICATIONS
FB00CD
All Configurations
Min
Input to Output Capacitance
Max
FB00FC
Min
5
Max
FB00KB
Min
5
Max
Units
5
pF
Dielectric Strength
500
500
500
Vac
Insulation Resistance @ 500 Vdc
109
109
109
Ohm
Output Junction Temperature @ ILOAD = Imax rated
125
125
125
°C
Maximum Junction Temperature (TJ Max.)
150
150
150
°C
Thermal Resistance Junction to Ambient (θJA)
110
110
110
°C/W
Thermal Resistance Junction to Case (θJC)
20
20
20
°C/W
FB 92
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2002 TELEDYNE RELAYS
FB\072002\Q1
Series FB
A) BI-DIRECTIONAL AND DC CONFIGURATION (SEE NOTE 4)
LOAD CURRENT DERATING CURVE
FIGURE 3
B) DC CONFIGURATION (SEE NOTE 4)
WIRING CONFIGURATIONS
FIGURE 1
INPUT CURRENT VS TURN-ON TIME
FIGURE 2
NORMALIZED ON RESISTANCE VS JUNCTION
TEMPERATURE.
FIGURE 4 (SEE NOTE 6)
NOTES:
1.
2.
3.
4.
5.
6.
7.
Series resistor required to limit input current to 50 mA
max.
The rated input current is 25 mA for all tests unless
otherwise specified.
Surge current is specified for 25°C, 10 cycles maximum at
a 1 Hz repetition rate with 10% duty cycle and 0.1 s.
duration.
Relays may drive loads connected to either positive or
negative referenced power supply lines. Inductive loads
must be diode suppressed.
Continuous load current is rated under the condition of still
air.
To calculate the maximum ON resistance for a given
junction temperature, find the normalized ON resistance
factor (NR) from Figure 4. Calculate the new ON
resistance as follows:
R(ON) = NR X R(ON) @ 25°C
Relays are tested in the bi-directional configuration only.
© 2002 TELEDYNE RELAYS
OUTPUT TURN-ON AND OFF TIMING
FIGURE 5
(800) 284-7007 • www.teledynerelays.com
FB 93
FB\072002\Q1