TFS280A - Vectron International

Filename: tfs280a.doc
version 1.4
VI TELEFILTER
Filter Specification
25.01.2002
TFS 280A
1/5
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedances *)
for input:
605 Ω // -1.1 pF
for output:
605 Ω // -1.1 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 280 A is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 280,455 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
tolerance/limit
Insertion loss
(Reference level)
Nominal frequency
ae = amin
3,1
fN
-
Centre frequency
fc
280,47
MHz
Guaranteed 3 dB signal band width
BW
170
kHz
min.
70
kHz
Relative attenuation
fN ± 35 kHz
arel
dB
max.
3
dB
min.
min.
10
55
dB
dB
1,2
dB
5
dB
280,455 MHz
fN ± 200 kHz
fN ± 420 kHz
25
65
dB
dB
Ultimate rejection
60
dB
1
µs
Group delay ripple
fN ± 35 kHz
max.
-
-
GD
Intermodulation
Input IP-3
(fN ± 25 kHz and fN ± 50 kHz each of -20 dBm)
-
µs
dBm
- 20 °C ... + 85 °C
Storage temperature range
Frequency inversion temperature
2
min. +15
Operating temperature range
Temperature coefficient of frequency**) TCf
max.
- 40 °C ... + 85 °C
- 0.036
+ 30
ppm/K²
-
°C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs280a.doc
version 1.4
VI TELEFILTER
Filter Specification
25.01.2002
TFS 280A
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
S280A
1
2...6
7
8...12
P05
Output
Package Ground
Input
Package Ground
Date code
Date code: Year+week
M
2000
N
2001
P
2002
...
50 Ohm test circuit 1
C1
C2
7
Input
50 Ohm
SAW
L1
1
Output
50 Ohm
L2
2,3,4,5,6,8,9,10,11,12
50 Ohm test circuit 2
L2
L1
7
Input
50 Ohm
1
Output
50 Ohm
SAW
C2
C1
2,3,4,5,6,8,9,10,11,12
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs280a.doc
version 1.4
VI TELEFILTER
25.01.2002
Filter Specification
TFS 280A
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
10 Hz to 500 Hz, 1,5 mm or 20g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
2. Vibration:
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER TAPE
W
:
Po
Do
:
:
E
:
F
:
G (min) :
P2
P1
:
:
16
± 0,3
4
1,5
± 0,1
+ 0,1
Do
Po
P2
E
1,75 ± 0,1
7,5 ± 0,1
0,6
2
8
± 0,1
± 0,1
Ao
F
D1
CT
W
Bo
G
D1(min) :
1,5
Ao
Bo
:
:
5,5
7,5
± 0,1
± 0,1
CT
:
13,5
± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
:
W2 (max) :
330
16,4 +2
22,4
N (min)
:
50
C
:
13 +0,5 / -0,2
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs280a.doc
version 1.4
VI TELEFILTER
25.01.2002
Filter Specification
TFS 280A
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs280a.doc
VI TELEFILTER
version 1.4
Filter Specification
25.01.2002
TFS 280A
5/5
History
Version
Reason of Changes
Name
Date
1.4
Add history.
Change date code from monthly to weekly system.
Change stability characteristic.
Change packing information.
Add typical data.
Comment terminating impedances.
Dr. Wall
25.01.2002
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.