Version 2.3 Filename: tfs110t.doc VI TELEFILTER Filter specification 13.03.2002 TFS 110 T 1/5 Measurement condition Ambient temperature: 23 °C Input power level : 0 dBm Terminating impedances at fc *: for input: for output: 930 Ω || - 13,5 pF 940 Ω || - 15,2 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 110 T is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 110.592 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae = amin Nominal frequency fN Centre frequency fc tolerance / limit 7,5 dB max. 14,0 dB 110,592 MHz - 110,592 MHz Relative attenuation arel fN fN ± ... fN ± 0,6 MHz ... fN ± 0,3 MHz - max. 3 dB 5 MHz 38 dB min. 30 dB 380 ns max. 800 Group delay ripple in PB Temperature coefficient 0,032 ppm/K nsec 2 Operating temperature range - 40 °C ... + 85 °C Storage temperature range - 40 °C ... + 85 °C Input power max. 10 dBm *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. Generated: Checked / approved: Construction and Pin Connection VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Version 2.3 Filename: tfs110t.doc VI TELEFILTER Filter specification 13.03.2002 TFS 110 T 2/5 P02 +0,20 2,0 Max. 1 2 +0,20 TFS 110T 6,50 - 0,10 (All dimensions in mm) 19 - 0,10 1 2 3 4 5 6 7 8 9 10 Date code Date code: M N P ... 1,02 Year+week 2000 2001 2002 2,31 1 Input RF Return Ground Ground Ground Output Output RF Return Ground Ground Ground Input 1,91 7,62 50 Ω test circut L1 L2 10 Input 5 Output 50 Ohm SAW 50 Ohm C1 C2 1,2,3,4,6,7,8,9 Stability characteristics VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Version 2.3 Filename: tfs110t.doc VI TELEFILTER Filter specification 13.03.2002 TFS 110 T 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: DIN IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 2000 min 300 mm min 500 mm min 300 mm T a p e (a ll d im e n s io n s in m m ) W : 32 Po : 4 Do : 1 ,5 E : 1 ,7 5 ± 0 ,1 P1 : 12 ± 0 ,1 D 1 (m in ) : 1 ,5 Ao : 7 ,1 ± 0 ,1 Bo : 1 9 .6 ± 0 ,1 ± 0 ,1 Ko : 2 ,0 t : 0 ,3 5 Ct : 2 5 ,5 Po t Ko X P1 Do P2 E ± 0 ,1 view direction Bo 2 So : pull off direction X-X 2 8 ,4 ± 0 ,1 Ct P2 + 0 ,5 W : S0 ± 0 ,3 ± 0 ,1 D1 ± 0 ,0 5 Ao X ± 0 ,1 SPEC-Gurt 0061/ 19X6,5 Q09016:02.001 Jul.10,01 W 2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 32,4 +2 38,4 N (min) : 100 C : 13 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Version 2.3 Filename: tfs110t.doc VI TELEFILTER Filter specification 13.03.2002 TFS 110 T 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 History VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Version 2.3 Filename: tfs110t.doc VI TELEFILTER Version Filter specification Reason of Changes 13.03.2002 TFS 110 T 5/5 Name Date 1.0 - identical with specification from hudson Sabah 06.01.2000 1.1 - history added Steiner 13.07.2000 1.2 - Change package to 15mm x 6mm - use harder conditions for “Stability characteristics” Herrler 17.08.2001 1.3 - change to centre frequency reference for attenuation - add additional attenuation requirements Steiner 29.08.2001 development specification 2.0 changes requested by customer introduced wider passband 10dB/20dB attenuation demands removed temperature range corrected according to TFS110B specification change 30 dB edge frequencies Steiner 23.11.2001 2.1 - changed values of rejection, group delay, operating temperature - changed package Pfeiffer 10.01.2002 2.2 - terminating impedance added - typical values added Pfeiffer 12.03.2002 2.3 - limit of max. input power added Pfeiffer 13.03.2002 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information