Tfs160b.doc version 1.3 VI TELEFILTER Filter Specification 16.05.2002 TFS 160B 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedance * Input 660 Ω || -1.6 pF Output 660 Ω || -1.6 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 160 B is the insertion loss. The insertion loss ae is defined as the minimum of attenuation in pass band. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 160,620 MHz without any tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value tolerance/limit Insertion loss (Reference level) ae 3 Nominal frequency fN - Centre frequency fC 160,624 MHz - 3 dB – bandwidth BW 100 kHz - Relative attenuation fN + 910 kHz arel 65 dB Usable signal bandwidth dB max. 5 dB 160,620 MHz - min 60 dB min. fN ±10 kHz Operating temperature range - 20 °C ... + 70 °C Storage temperature range - 30 °C ... + 85 °C Temperature coefficient of frequency Frequency inversion temperature T0 TCf** -0,036 ppm/K² + 25 °C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) Generated: Checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs160b.doc version 1.3 VI TELEFILTER Filter Specification 16.05.2002 TFS 160B 2/5 Construction and pin configuration (All dimensions in mm) Pin 2 Input Pin 7 Output Pin 1,3,4,5,6,8,9,10 Ground TFS160B P23 Date code Datecode: M N P ... 1 2 Year + week 2000 2001 2002 3 10 4 9 5 8 7 6 50 Ω matching network 1 L1 L2 7 2 Input 50 Ohm Output 50 Ohm SAW C1 C2 1,3,4,5,6,8,9,10 50 Ω matching network 2 7 2 Input 50 Ohm SAW C1 L1 C2 Output 50 Ohm L2 1,3,4,5,6,8,9,10 Note: The filter operates in the matching network in the same manner if the filter is inserted with a rotation of 180 °. VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs160b.doc version 1.3 VI TELEFILTER 16.05.2002 Filter Specification TFS 160B 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing: Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 2000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) EMBOSSED CARRIER TAPE W Po Do : : : 16 ± 0,3 4 ± 0,1 1,5 + 0,1 E F : : 1,75 ± 0,1 7,5 ± 0,1 G (min) : P2 : 0,6 2 ± 0,1 P1 : 12 D1(min) : Ao : 1,5 7,6 Bo CT 9,6 ± 0,1 13,5 ± 0,1 : : Do Po P2 E Ao F D1 CT W Bo ± 0,1 G ± 0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 16,4 +2 22,4 N (min) : 60 C : 12,8 ± 0,1 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs160b.doc version 1.3 VI TELEFILTER 16.05.2002 Filter Specification TFS 160B 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs160b.doc version 1.3 VI TELEFILTER Filter Specification 16.05.2002 TFS 160B 5/5 History Version Reason of Changes Name Date 1.1 Generate Filter specification in actually format. Add “History”. Herrler 24.07.2001 1.2 Correct typo in relative attenuation. Correct reel information. Change matching network. Add typical value for centre frequency. Correct marking. Dr. Wall 28.01.2002 1.3 Correct package drawing. Dr. Wall 16.05.2002 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.