5219/5221 - Vectron International

REV
A
DESCRIPTION
DATE
4/23/14
NIR-52399
PREP
DF/SM
APPD
LT
Oscillator Specification, Hybrid VCXO
For
MOUNT HOLLY SPRINGS, PA 17065
THE RECORD OF APPROVAL FOR THIS
DOCUMENT IS MAINTAINED ELECTRONICALLY
WITHIN THE ERP SYSTEM
Hi-Rel Standard, LVDS Output
CODE IDENT NO
SIZE
00136
A
DWG. NO.
UNSPECIFIED TOLERANCES: N/A
VECTRON INTERNATIONAL PROPRIETARY
REV
DOC204899
A
SHEET 1 0F 15
1.
SCOPE
1.1
General. This specification defines the design, assembly and functional evaluation of high
reliability, hybrid voltage controlled oscillators produced by Vectron International. Devices
delivered to this specification represent the standardized Parts, Materials and Processes (PMP)
Program developed, implemented and certified for advanced applications and extended
environments.
1.2
Applications Overview. The designs represented by these products were primarily developed for
the MIL-Aerospace community. The lesser Design Pedigrees and Screening Options imbedded
within DOC204899 bridge the gap between Space and COTS hardware by providing custom
hardware with measures of mechanical, assembly and reliability assurance needed for Military or
Ruggedized COTS environments.
2.
APPLICABLE DOCUMENTS
2.1
Specifications and Standards. The following specifications and standards form a part of this
document to the extent specified herein. The issue currently in effect on the date of quotation will
be the product baseline, unless otherwise specified. In the event of conflict between the texts of
any references cited herein, the text of this document shall take precedence.
Military
MIL-PRF-55310
MIL-PRF-38534
Standards
MIL-STD-202
MIL-STD-750
MIL-STD-883
MIL-STD-1686
Other
DOC204943
QSP-90100
VL-65339
DOC203982
Oscillators, Crystal Controlled, General Specification For
Hybrid Microcircuits, General Specification For
Test Method Standard, Electronic and Electrical Component Parts
Test Method Standard, Test Methods for Semiconductor Devices
Test Methods and Procedures for Microelectronics
Electrostatic Discharge Control Program for Protection of Electrical and
Electronic Parts, Assemblies and Equipment
Test Specification, Hybrid VCXO, Hi-Rel Standard, LVDS Output
Quality Systems Manual, Vectron International
Identification Common Documents, Materials and Processes, Hi-Rel XO
DPA Specification
3.
GENERAL REQUIREMENTS
3.1
Classification. All devices delivered to this specification are of hybrid technology conforming to
Type 1, Class 2 of MIL-PRF-55310 and have a Class 1C ESDS rating. Primarily developed as a
Class S equivalent specification, options are imbedded within it to also produce Class B,
Engineering Model and Ruggedized COTS devices.
3.2
Item Identification. Unique Model Number Series’ are utilized to identify device package
configurations as listed in Table 1.
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
2
VECTRON INTERNATIONAL PROPRIETARY
3.3
Absolute Maximum Ratings.
a. Supply Voltage Range (VCC):
b. Storage Temperature Range (TSTG):
c. Junction Temperature (TJ):
d. Lead Temperature (soldering, 10 seconds):
e. Weight
f. Control Voltage Input (Vc)
0.3Vdc to +4.0Vdc
-65°C to +125°C
+150°C
+300°C
5 grams
-0.3Vdc to +4.0Vdc
3.4
Design, Parts, Materials and Processes, Assembly, Inspection and Test.
3.4.1
Design. The ruggedized designs implemented for these devices are proven in military and space
applications under extreme environments. Designs utilize 4-point crystal mounting in
combination with Established Reliability (MIL-ER) components where possible. When specified,
radiation hardening up to 100krad (Si) (RHA level R) can be included without altering the
device’s internal topography.
3.4.1.1 Design and Configuration Stability. Barring changes to improve performance by reselecting
passive chip component values to offset component tolerances, there will not be fundamental
changes to the design or assembly or parts, materials and processes after first product delivery of
that item without written approval from the procuring activity.
3.4.1.2 Environmental Integrity. Designs have passed the environmental qualification levels of MILPRF-55310. These designs have also passed extended dynamic levels of at least:
Sine Vibration: MIL-STD-202, Method 204, Condition G (30g pk.)
Random Vibration: MIL-STD-202, Method 214, Condition II-J (43.92g rms)
Mechanical Shock: MIL-STD-202, Method 213, Condition F (1500g, 0.5ms)
3.4.2
Prohibited Parts, Materials and Processes. The items listed are prohibited for use in high
reliability devices produced to this specification.
a. Gold metallization of package elements without a barrier metal.
b. Zinc chromate as a finish.
c. Cadmium, zinc, or pure tin external or internal to the device.
d. Plastic encapsulated semiconductor devices.
e. Ultrasonically cleaned electronic parts.
f. Heterojunction Bipolar Transistor (HBT) technology.
g. ‘getter’ materials
3.4.3
Assembly. Manufacturing utilizes standardized procedures, processes and verification methods to
produce MIL-PRF-55310 Class S / MIL-PRF-38534 Class K equivalent devices. MIL-PRF38534 Group B Option 1 in-line inspection is included on radiation hardened part numbers to
further verify lot pedigree. Traceability of all components and production lots are in accordance
with MIL-PRF-38534, as a minimum. Tabulated records are provided as a part of the deliverable
data package. Devices are handled in accordance with MIL-STD-1686 for Class 1 devices.
3.4.4
Inspection. The inspection requirements of MIL-PRF-55310 apply to all devices delivered to this
document. Inspection conditions and standards are documented in accordance with the Quality
Assurance, ISO-9001 derived, System of QSP-90100.
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
3
VECTRON INTERNATIONAL PROPRIETARY
3.4.5
Test. The Screening test matrix of Table 5 is tailored for selectable-combination testing to
eliminate costs associated with the development/maintenance of device-specific documentation
packages while maintaining performance integrity.
3.4.6
Marking. Device marking shall be in accordance with the requirements of MIL-PRF-55310.
3.4.7
Ruggedized COTS Design Implementation. Design Pedigree “D” devices (see ¶ 5.2) use the
same robust designs found in the other device pedigrees. They do not include the provisions of
traceability or the Class-qualified components noted in paragraphs 3.4.3 and 4.1.
4.
DETAIL REQUIREMENTS
4.1
Components
4.1.1
Crystals. Cultured quartz crystal resonators are used to provide the selected frequency for the
devices. The optional use of Premium Q swept quartz can, because of its processing to remove
impurities, be specified for better frequency aging characteristics. In accordance with MIL-PRF55310, the manufacturer has a documented crystal element evaluation program.
4.1.2
Passive Components. Established Reliability (ER) failure level R minimum passive components
are procured from QPL suppliers where possible. Lot evaluations are in accordance with MILPRF-55310 or Enhanced Element Evaluation as specified in Table 7.
4.1.3
Class S Active Devices. Devices are assembled with semiconductors and an LVDS chip used to
provide the LVDS output. The semiconductors are procured from wafer lots that have passed
MIL-PRF-55310 Lot Acceptance Tests for Class S devices. The LVDS microcircuit die is
sourced in accordance with Standard Microcircuit Drawing 5962R9865105V9A, Class V (MILPRF-38535) qualified device. Although radiation testing is not performed at the oscillator level,
active devices are acceptable for use in environments of up to 100 krads total dose by analysis,
design or certification of the individual components. In addition, the semiconductors are
considered insensitive to Single Event Effects.
4.1.3.1 Class B Active Devices. Active devices for design Pedigree letters “B” and “C” are procured from
wafer lots that have passed MIL-PRF-55310 element evaluations for Class B devices, at a
minimum.
4.1.4
Packages. Packages are procured that meet the construction, lead materials and finishes as
specified in MIL-PRF-55310. Package lots are upscreened in accordance with the requirements
of MIL-PRF-38534 as applicable.
4.1.5
Traceability. Class S active device lots are homogenous and traceable to the manufacturer’s
individual wafer. Swept Quartz Crystals are traceable to the quartz bar and the processing details
of the autoclave lot, as applicable. All other elements and materials are traceable to their
manufacturer and incoming inspection lots.
4.1.6
Enhanced Element Evaluation. When Design Pedigree Option “E” is specified, active and passive
devices with Enhanced Element Evaluation as listed in Table 6 and 7 shall be implemented for the
highest reliability preference.
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
4
VECTRON INTERNATIONAL PROPRIETARY
4.2
Mechanical.
4.2.1
Package Outline. Table 1 links each Hi-Rel Standard Model Number of this specification to a
corresponding package style. Mechanical Outline information of each package style is found in
the referenced Figure.
4.2.2
Thermal Characteristics. The worst case thermal characteristics of each package style and active
device are found in Table 4.
4.3
Electrical.
4.3.1
Input Power. Devices are designed for standard +3.3 volt dc operation, ±5%. Current is
measured, no load, at maximum rated operating Voltage.
4.3.2
Temperature Range. Operating range is -40°C to +85°C. Units may be operated from -55°C to
+125°C; however, electrical performance may be degraded.
4.3.3
Absolute Pull Range. Absolute pull range is defined as the minimum guaranteed amount the
VCXO can be varied, about the center frequency (fo). It accounts for degradations including
temperature stability (-40 to 85°C), aging (15 years), radiation effects, power supply variations
(±5%) and load variations (±10%).
4.3.4
Frequency Aging. When tested in accordance with MIL-O-55310 Group B inspection, the 15year aging projection shall not cause the minimum APR limit to be exceeded.
4.3.5
Operating Characteristics. Symmetrical square wave limits are dependent on the device
frequency and are in accordance with Table 2 and Figure 1. Start-up time is 10.0 msec.
maximum.
4.3.6
Output Load. See Figure 2.
5.
QUALITY ASSURANCE PROVISIONS AND VERIFICATION
5.1
Verification and Test. Device lots shall be tested prior to delivery in accordance with the
applicable Screening Option letter as stated by the 15th character of the part number. Table 5 tests
are conducted in the order shown and annotated on the appropriate process travelers and data
sheets of the governing test procedure. For devices that require Screening Options that include
MIL-PRF-55310 Group A testing, the Post-Burn-In Electrical Test and the Group A Electrical
Test are combined into one operation.
5.1.1
Screening Options. The Screening Options, by letter, are summarized as:
A
Modified MIL-PRF-38534 Class K
B
Modified MIL-PRF-55310 Class B Screening & Group A Quality Conformance
Inspection (QCI)
C
Modified MIL-PRF-55310 Class S Screening & Group A QCI
E
Modified MIL-PRF-55310 Class B Screening, Groups A & B QCI
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
5
VECTRON INTERNATIONAL PROPRIETARY
F
G
X
Modified MIL-PRF-55310 Class S Screening, Groups A & B QCI
Modified MIL-PRF-55310 Class B Screening & Post Burn-in Nominal Electricals
Engineering Model (EM)
5.2
Optional Design, Test and Data Parameters. The following is a list of design, assembly,
inspection and test options that can be selected or added by purchase order request.
a. Design Pedigree (choose one as the 5th character in the part number):
(E) Enhanced Element Evaluation, 100krad Class S die, Premium Q Swept Quartz
(R) Hi-Rel design w/ 100krad Class S die, Premium Q Swept Quartz
(V) Hi-Rel design w/ 100krad Class S die, Cultured Quartz
(X) Hi-Rel design w/ Cultured Quartz, Class S die
(B) Hi-Rel design w/ Swept Quartz, Class B die
(C) Hi-Rel design w/ Cultured Quartz, Class B die
(D) Hi-Rel design w/ Cultured Quartz and commercial grade components
b. Input Voltage, (B) for 3.3V as the 14th character
c. Frequency-Temperature Slew Test
d. Radiographic Inspection
e. Group C Inspection: MIL-PRF-55310 (requires 8 test specimens)
f. Group C Inspection: MIL-PRF-38534 [requires 8 test specimens – Life (5), RGA (3)]
g. Internal Water-Vapor Content (RGA) samples and test performance
h. MTBF Reliability Calculations
i. Worst Case/Derating Analysis
j. Deliverable Process Identification Documentation (PID)
k. Customer Source Inspection (pre-cap / final)
5.3
Test Conditions. Unless otherwise stated herein, inspections are performed in accordance with
those specified in MIL-PRF-55310 and MIL-PRF-38534, in that order. Process travelers identify
the applicable methods, conditions and procedures to be used. Examples of electrical test
procedures that correspond to MIL-PRF-55310 requirements are shown in Table 3.
5.4
Special Tests and Descriptions.
5.4.1
Frequency-Temperature Slew. Frequency-Temperature Slew Test has been developed as an
indicator of higher than normal internal water vapor content. The incremental temperature sweep
from +85°C to -40°C and back to +85°C records output frequency fluctuations emulating the
mass loading of moisture deposited on the crystal blank surface. Though not replacing a
customer’s internal water-vapor content (RGA) requirement, confidence is increased without
destructively testing otherwise good devices.
5.5
Deliverable Data. The manufacturer supplies the following data, as a minimum, with each lot of
devices:
a. Completed assembly and screening lot travelers, including rework history.
b. Electrical test variables data, identified by unique serial number.
c. Frequency-Temperature Slew plots, Radiographic films, Group C data and RGA data as
required by purchase order.
5.6
Discrepant Material. All MRB authority resides with the procuring activity.
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
6
VECTRON INTERNATIONAL PROPRIETARY
5.7
Failure Analysis. Any catastrophic failure (no clocking, no current) at Post Burn-In or after will
be evaluated for root cause. The customer will be notified after occurrence and upon completion
of the evaluation.
6.
PREPARATION FOR DELIVERY
6.1
Packaging. Devices will be packaged in a manner that prevents handling and transit damage
during shipping. Devices will be handled in accordance with MIL-STD-1686 for Class 1 devices.
7.
ORDERING INFORMATION
7.1
Ordering Part Number. The ordering part number is made up of an alphanumeric series of
15 characters. Design-affected product options, identified by the parenthetic letter on the
Optional Parameters list (¶ 5.2a and b), are included within the device part number.
The Part Number breakdown is described as:
5219 R 160M0000 B F
Model # (Table 1)
Screening Option
per Table 5, 5.1.1
Input Voltage
B = 3.3V
Design Pedigree
E = Enhanced Element Evaluation,
100krad Class S die, Swept Quartz
Frequency
R = 100krad Class S die, Swept
Quartz
V = 100krad Class S die, Non-Swept
Quartz
X = Class S die, Non-Swept Quartz
B = Class B die, Swept Quartz
C = Class B die, Non-Swept Quartz
D = Ruggedized COTS: Commercial
Grade Components, Non-Swept
Quartz
7.1.1
Model Number. The device model number is the four (4) digit number assigned to a
corresponding package and output combination per Table 1.
7.1.2
Design Pedigree. Class S variants correspond to either letter “E”, “R”, “V” or “X” and are
described in paragraph 5.2a. Class B variants correspond to either letter “B” or “C” and are
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
7
VECTRON INTERNATIONAL PROPRIETARY
described in paragraph 5.2a. Ruggedized COTS, using commercial grade components,
corresponds to letter “D”.
7.1.3
Output Frequency. The nominal output frequency is expressed in the format as specified in MILPRF-55310 utilizing eight (8) characters.
7.1.4
Input Voltage. Voltage is the 14th character, letter “B” represents +3.3V.
7.1.5
Screening Options. The 15th character is the Screening Option (letter A thru G or X) selected
from Table 5.
7.2
Optional Design, Test and Data Parameters. Test and documentation requirements above that of
the standard high reliability model shall be specified by separate purchase order line items (as
listed in ¶ 5.2c thru k).
HI-REL
STANDARD
MODEL #
5219
PACKAGE
Vcc
Vc
16 Lead Flatpack
16
1
PIN I/O 1/
Q Qnot
7
8
5221
16 Lead Flatpack
16
1
7
8
1/. All unassigned pins have no internal connections or ties.
Gnd/Case
MECHANICAL
OUTLINE
9, 11
FIGURE 2
9, 11
FIGURE 3
TABLE 1 - Item Identification and Package Outline
Frequency Range @ 3.3V Operation: 80 MHz to 200 MHz 1/
Temperature Range: -40°C to +85°C
Absolute Pull Range: ±20 ppm min.
Control Voltage (Vc) Range: 0.0V to +3.3V
Slope: Positive
Linearity: ±10% max.
F vs. V Gain: 55 ppm/V typical
Sub-Harmonics: -30 dBc max.
Frequency-Voltage Tolerance: ±4 ppm max. (Vcc ±5%)
Frequency Aging: 15 year projection based on 30 day test included in APR calculation
Start-up Time: 10.0 ms max.
Differential Output Voltage VOD: 250mV to 450mV
Offset Voltage VOS: 1.125V to 1.450V
Frequency
Current
Rise / Fall
Duty Cycle
BW Jitter,
Range
(No load, 3.465V)
Times
12kHz-20MHz
(MHz)
(mA max)
(ps max.)
(%)
(ps rms max)
80.0 – 100.0
35
600
40 to 60
1.0
>100.0 – 200.0
40
500
40 to 60
0.5
1/. Waveform measurement points and logic limits are in accordance with Figure 1.
2/. Measured with Wavecrest SIA-3000 Signal Integrity Analyzer
TABLE 2 - Electrical Performance Characteristics
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
8
VECTRON INTERNATIONAL PROPRIETARY
OPERATION LISTING
REQUIREMENTS AND
CONDITIONS 1/
@ all Electrical tests
Input Current (no load)
MIL-PRF-55310, Para 4.8.5.1
Initial Accuracy @ Ref. Temp.
MIL-PRF-55310, Para 4.8.6
Output Logic Voltage Levels
MIL-PRF-55310, Para 4.8.21.3
Rise and Fall Times
MIL-PRF-55310, Para 4.8.22
Duty Cycle
MIL-PRF-55310, Para 4.8.23
@ Post Burn-In Electrical only
Overvoltage Survivability
MIL-PRF-55310, Para 4.8.4
Initial Freq. – Temp. Accuracy
MIL-PRF-55310, Para 4.8.10.1
Freq. – Voltage Tolerance
MIL-PRF-55310, Para 4.8.14
Start-up Time (fast/slow start)
MIL-PRF-55310, Para 4.8.29
1/. Waveform measurement points and logic limits are in accordance with Figure 1.
TABLE 3 - Electrical Test Parameters
Model #
5219/5221
Thermal Resistance
Junction to Case θjc
(°C / W)
150
∆ Junction Temp. Tj
(°C @ max. power)
Weight
(Grams)
2.1
7.2
Note. These oscillators contain multiple active devices. This calculation shows the
worst case θjc and temperature rise of those devices.
TABLE 4 - Thermal Characteristics and Weight
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
9
VECTRON INTERNATIONAL PROPRIETARY
OPN.
NO.
OPERATION LISTING
REQUIREMENTS AND CONDITIONS
MIL Class Similarity
SCREENING
1
2
Non-Destruct Bond Pull 3/
Internal Visual
MIL-STD-883, Meth 2023
MIL-STD-883, Meth 2017 Class K,
Meth 2032 Class K
MIL-STD-883, Meth 1008, Cond C,
150°C, 48 hours min.
MIL-STD-883, Meth 1011, Cond A
3
Stabilization (Vacuum) Bake
4
Thermal Shock
5
Temperature Cycle
6
Constant Acceleration
7
Particle Impact Noise Detection
8
Electrical Testing, Pre Burn-In
9
Freq-Temp Slew Test
10
1st Burn-In
11
Electrical Testing, Intermediate
12
2nd Burn-In
13
14
Electrical Testing, Post Burn-In
(Group A)
Seal: Fine Leak
15
16
Seal: Gross Leak
Radiographic Inspection
17
18
19
Solderability
External Visual & Mechanical
Aging, 30 Day
(M55310 Group B)
Option
A
K
Option
B
B-
Option
C
S-
Option
E
B
Option
F
S
Option
G
Option
X
EM
100%
100%
100%
100%
100%
100%
100%
Completed During Assembly
NR
NR
X
NR
X
NR
NR
MIL-STD-883, Meth 1010, Cond. B,
10 cycles min.
MIL-STD-883, Meth 2001, Cond A,
Y1 plane only, 5000 g’s
MIL-STD-883, Meth 2020, Cond B
X
X
X
X
X
X
NR
X
X
X
X
X
X
NR
X
X
X
X
X
NR
X
Perform tests in Table 3. Nominal Vcc, nominal
temperature
Operating temp. range, frequency plotted at 1.0°C
steps
MIL-STD-883, Meth 1015, Condition B
X
X
X
X
X
X
X
AR
AR
AR
AR
AR
NR
NR
X
160 hrs.
X
X
160 hrs.
NR
X
240 hrs.
NR
X
160 hrs.
NR
X
240 hrs.
NR
X
160 hrs.
NR
NR
NR
X
160 hrs.
X
NR
NR
NR
NR
NR
NR
X
X
X
X
NR
X
X
X
X
X
X
nom. Vcc
X
X
X
X
AR
X
AR
X
AR
X
X
X
NR
X
NR
1/
X
NR
1/
X 2/
NR
1/
X 2/
NR
1/
X 2/
13 pcs.
1/
X 2/
X
1/
X 2/
NR
NR
X 2/
NR
Perform tests in Table 3. Nominal Vcc, nominal
temperature
MIL-STD-883, Meth 1015, Condition B
Perform tests in Table 3. Nominal Vcc & extremes,
nominal temperature & extremes
MIL-STD-883, Meth 1014, Cond A2
5 x 10-8 atm cc/sec max
MIL-STD-202, Meth 112, Cond D
MIL-STD-883, Meth 2012
MIL-STD-883, Meth 2003
MIL-STD-883, Meth 2009
MIL-PRF-55310, para. 4.8.35.1
LEGEND: X = Required, NR = Not Required, AR = As Required
TABLE 5 - Test Matrix
1/ Performed at package LAT. Include LAT data sheet
2/ When specified, RGA samples will be removed from the lot after completion of this operation. Use of Screening failures require customer concurrence.
3/ Not performed on Option B, E, G and X units.
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
10
VECTRON INTERNATIONAL PROPRIETARY
X
Subgroup
Class
Test
Condition
(accept number)
Mil-PRF38534
Reference
Paragraph
Perform at room
ambient
100%
C.3.3.1
100%
C.3.3.2
10(0) or 22(0)
(Notes 1 & 2)
C.3.3.3
C.3.3.4.2
C.3.3.3
Mil-STD-750
K
Method
Quantity
Element Electrical
A. May perform at wafer level
B. All failures shall be removed
from the lot
1
X
2
X
Element Visual
3
X
Internal Visual
4
X
X
Temperature Cycling
Surge Current
(when applicable)
Constant Acceleration
X
2069, 2070,
2072, 2073
2069, 2070,
2072, 2073, 2074
1051
4066
C
A or B as
specified
Y1 direction
20,000 G /
10,000 G for
Pd ≥ 10W
2006
2001
X
10(0)
22(0)
(See Notes 1 & 2)
Interim Electrical
C.3.3.4.3
1039
1042
1038
X
High Temperature
Reverse Bias (HTRB)
X
Interim Electrical & Delta
X
Burn-In 240 hours
X
Post Burn-In Electrical
X
Steady State Life
1000 hours
X
Final Electrical
1039, 1042
1038
1040
A
B
A
Complete
Within 16 hrs of
HTRB
completion
B
A
B
C.3.3.4.3
1026
1037
1042
1048
5
X
Wire Bond Evaluation
2011
6
X
SEM
2018
2077
C.3.3.4.3
C.3.3.3
C.3.3.5
10(0) wires or
20(1) wires
See method 2018
or 2077 & Note 2
C.3.3.6
NOTES:
1. Subgroups 3, 4, & 5 shall be performed on a sample of 10 die if the wafer lot is from a QPL/QML line. If the die are
from commercial wafer lots, then the sample size shall be 22 die. Die from QPL/QML wafers not meeting the QPL/QML
requirements and downgraded to commercial grade shall not be used.
2. Subgroups 3, 4 & 5 shall be performed in the order listed in Table 1. Subgroup 6 may be performed at any time.
TABLE 6 - SEMICONDUCTOR ENHANCED ELEMENT EVALUATION
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
11
VECTRON INTERNATIONAL PROPRIETARY
Parts Type
Ceramic Capacitors
M55681 FRL S or
M123 (chips)
Resistors
M55342 FRL R or
S
Inductors
Custom
Test
Requirement
Paragraph
Sample size
Allowable Reject(s)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Group A
Group B
Mil-Std-981
Mil-Std-981
Mil-Std-981
Mil-Std-981
Mil-Std-981
Mil-Std-981
TABLE 7: PASSIVE COMPONENT ENHANCED ELEMENT EVALUATION
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
12
VECTRON INTERNATIONAL PROPRIETARY
FIGURE 1
Differential Output Waveform
FIGURE 2
Output Load, 100Ω between outputs
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
13
VECTRON INTERNATIONAL PROPRIETARY
FIGURE 3
Model 5219 Package Outline
FIGURE 4
Model 5221 Package Outline
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
14
VECTRON INTERNATIONAL PROPRIETARY
DOCUMENT CHANGE RECORD
Revision
-
Change
Preliminary Release
SIZE
CODE IDENT NO.
A
00136
UNSPECIFIED TOLERANCES
DWG NO.
REV.
SHEET
N/A
DOC204899
A
15
VECTRON INTERNATIONAL PROPRIETARY