Product Data Sheet

Fixed Frequency Crystal Oscillator (XO)
The F-Type Fixed-Frequency Crystal Oscillator (XO) is a hybrid clock oscillator
designed for use in both CMOS and TTL applications. It is available in either
commercial or industrial temperature ranges and can be ordered with a 3-state option.
The 3-state option allows the output of the oscillator to be placed in a high-impedance
state for board-level testing by automatic testing equipment. The F-Type XO is also
available in a surface-mount configuration. The pin through-hole version is compatible
with a 14-pin DIP footprint.
Typical applications for the F-Type oscillator are to provide clock signals for digital
signal processing chips and microprocessors. Tight stabilities compatible with SONET
and STRATUM 4 telephony requirements are available.
Features
z
z
z
z
z
z
Industry Standard Pinout
Stability to 20 ppm
TTL or CMOS
Choice of Temperature Range
Tri-State Output Option
Hermetically Sealed Metal Package
Mechanical Characteristics
Parameter
Mechanical Shock
Mechanical Vibration
Temperature Cycle
Gross Leak Test
Fine Leak Test
Seal Strength
Bend Test
Marking
ESD
Description
MIL-STD-883C, Method 2002.3, Condition A.
MIL-STD-883C, Method 2007.1, Condition A.
MIL-STD-883C, Method 1010, Condition A.
All Units 100% leak tested in deionized water.
All Units test to MIL-STD-883C, Method 1014.
2 lbs. maximum force perpendicular to top and bottom.
MIL-STD-202E, Method 211A, Condition C.
MIL-STD-202E, Method 215.
MIL-STD-883D, Method 3015; 1000v HBM, 500v CDM
Electrical Characteristics
Parameter
Symbol
Min
Typ
Max
Unit
3.3V 5.0V 3.3V 5.0V 3.3V 5.0V
Frequency Range
f0
1 to 80
Mhz
Temperature Range
TO
0 to 70 or -40 to 85
°C
±25, ±50 or ±100
ppm
3.3 (±10%) or 5.0 (±10%)
V
Stability Options1
Supply Voltage
VDD
Supply Current
1 to 20 MHz
21 to 80 MHz
IDD
Output Levels
High
Low
Output Rise/Fall Time2
1 to 20 MHz
21 to 80 MHz
V OH
V OL
3.0
tR/F
Tri-State
Out Enable
Out Disable (High Imp.)
Output Symmetry
4.5
2.0
-
4.0
45
-
10
35
15
50
-
0.3
0.5
-
5
4
8
6
-
0.5
0.8
50
55
mA
V
ns
V
%
tSU
3
ms
Output Load Options
-
TTL or CMOS, 15 or 50 pF
-
Storage Temperature
TS
Start-up Time
-55
-
125
°C
1 Inclusive of calibration tolerance at 25°C, over the operating temperature range, and
aging.
2 Current consumption is typically 0.4 mA/MHz above 20 MHz frequencies.
3 Transition times are measured between 10% and 90% of VDD
Outline Drawing
Standard Frequencies*
2.000
2.048
3.088
4.096
8.000
8.192
10.000 11.0592 16.000 20.000
28.800 30.000 32.768
34.468 40.000
45.000 49.152 51.840
55.000 60.000
64.000 66.000 80.000
* Other Frequencies available upon request.