Filter specification
TFS 499A
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 499 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
1,5
Nominal frequency
fN
-
PB
-
Passband
Pass band variation
0,9
Absolute attenuation
0,3
425
526
580
800
MHz
MHz
MHz
MHz
MHz
… 425
… 474
… 580
… 800
… 1000
dB
tolerance / limit
max.
fN
4,0
±
dB
499
MHz
13
MHz
1,5
dB
dB
max.
53
17
18
49
61
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
40
10
10
40
50
dB
dB
dB
dB
dB
17
ns
ns
aabs
MHz
MHz
MHz
MHz
MHz
Group delay ripple within PB
max.
200
IP3
-
min.
30
dBm
Input power level
-
max.
10
dBm
-
- 20 °C ... + 55 °C
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf *
-76
- 45 °C ... + 85 °C
ppm/K
-
*) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 499a.doc
Version 1.1
VI TELEFILTER
09.05.2008
Filter specification
TFS 499A
2/5
0
1.38
-1
1.23
-20
-2
1.08
-30
-3
0.93
-40
-4
0.78
-5
0.63
-6
0.48
-70
-7
0.33
-80
-8
0.18
-90
-9
0.03
-50
-60
-100
49
139
229
319
409
499
589
frequency in MHz
679
769
859
-10
479
949
483
487
491
495
499
503
frequency in MHz
507
511
515
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
-0.12
519
Construction and pin connection
(All dimensions in mm)
7
499A
● W19
1
SQ 3,81 +0,2/-0,1
5
3
5
0,1
7
0,6
12
0%
%
d
3
1,78
2,54
1
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
W
X
A
...
Year + week
2008
2009
2010
1,2 Max.
Date code
1
2
3
4
5
6
7
8
1,78
50 Ω Test circuit
L1
2
5
L2
SAW
1, 3, 4, 6
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 499a.doc
Version 1.1
VI TELEFILTER
09.05.2008
Filter specification
TFS 499A
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 499a.doc
Version 1.1
VI TELEFILTER
09.05.2008
Filter specification
TFS 499A
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 499a.doc
VI TELEFILTER
Version 1.1
Filter specification
09.05.2008
TFS 499A
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of development specification
Strehl
22.02.2008
1.1
Change construction and pin connection, add typical values
Add filter characteristic, generation of filter specification
S. Channaa
09.05.2008
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.